Effect of Filler Conductive Threshold on Cathodic Protection and Anticorrosion Mechanism of Zinc-rich Epoxy Coatings

Abstract In this study, reduced graphene oxide (rGO) fillers with electrical conductivities spanning nearly five orders of magnitude (4.2 × 10–4 – 20.58 S/cm) were prepared by hydrothermal reduction and incorporated at a fixed loading of 0.5 wt % into zinc-rich epoxy coatings containing 50 wt % zinc powder. The influence of the reduction-dependent rGO state on coating structure, interfacial properties, cathodic protection, and corrosion resistance was systematically evaluated. A non-monotonic conductivity–performance relationship was observed, with rGO160 (1.62 S/cm) showing the best overall protection under the present formulation. XPS and FTIR revealed that rGO160 retained an intermediate surface polarity, while cross-sectional SEM and mechanical tests indicated a dense coating structure, reduced interfacial defects, and the highest pull-off adhesion strength (∼6.4 MPa). KPFM further showed a comparatively uniform contact-potential-difference distribution. After 30 days of immersion, the MZrZE-rGO160 coating retained the highest low-frequency impedance modulus (|Z|0.01Hz ≈ 4 × 107 Ω·cm2) and exhibited the lowest relative corrosion propagation after 300 h of salt-spray exposure. DFT calculations showed comparatively less favorable H2O and O2 adsorption on the idealized rGO160 surface (+0.03 and +0.61 eV, respectively), serving as supplementary thermodynamic descriptors rather than direct kinetic evidence. The results demonstrate that the optimum protection arises from the coupled balance of conductivity, surface chemistry, sheet dispersion/restacking, conductive-network connectivity, and coating integrity. Accordingly, 1.62 S cm–1 should be regarded as a formulation-dependent optimum among the investigated rGO fillers rather than a universal conductivity threshold.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-10-20
DOI
https://doi.org/10.1021/acsami.6c11689
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Filler Conductive Threshold on Cathodic Protection and Anticorrosion Mechanism of Zinc-rich Epoxy Coatings

Huachao Ma, Kuilin Lv, Yukang Sun, Junfeng Li et al.
ACS Applied Materials & Interfaces
Corrosion Behavior and Inhibition
article

Effect of Filler Conductive Threshold on Cathodic Protection and Anticorrosion Mechanism of Zinc-rich Epoxy Coatings

Huachao Ma, Kuilin Lv, Yukang Sun, Junfeng Li, Xiaolong Zhao, Yu Wang
article en

Abstract

Abstract In this study, reduced graphene oxide (rGO) fillers with electrical conductivities spanning nearly five orders of magnitude (4.2 × 10–4 – 20.58 S/cm) were prepared by hydrothermal reduction and incorporated at a fixed loading of 0.5 wt % into zinc-rich epoxy coatings containing 50 wt % zinc powder. The influence of the reduction-dependent rGO state on coating structure, interfacial properties, cathodic protection, and corrosion resistance was systematically evaluated. A non-monotonic conductivity–performance relationship was observed, with rGO160 (1.62 S/cm) showing the best overall protection under the present formulation. XPS and FTIR revealed that rGO160 retained an intermediate surface polarity, while cross-sectional SEM and mechanical tests indicated a dense coating structure, reduced interfacial defects, and the highest pull-off adhesion strength (∼6.4 MPa). KPFM further showed a comparatively uniform contact-potential-difference distribution. After 30 days of immersion, the MZrZE-rGO160 coating retained the highest low-frequency impedance modulus (|Z|0.01Hz ≈ 4 × 107 Ω·cm2) and exhibited the lowest relative corrosion propagation after 300 h of salt-spray exposure. DFT calculations showed comparatively less favorable H2O and O2 adsorption on the idealized rGO160 surface (+0.03 and +0.61 eV, respectively), serving as supplementary thermodynamic descriptors rather than direct kinetic evidence. The results demonstrate that the optimum protection arises from the coupled balance of conductivity, surface chemistry, sheet dispersion/restacking, conductive-network connectivity, and coating integrity. Accordingly, 1.62 S cm–1 should be regarded as a formulation-dependent optimum among the investigated rGO fillers rather than a universal conductivity threshold.

ACS Applied Materials & Interfaces
Korea Testing Certification (KR), China Building Materials Academy (CN)
Openalex Percentile: Top 28%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.