Laser stabilized to a room-temperature cavity with AlGaAs coatings reaching 4.2 × 10 −17 fractional frequency instability

We present a laser system referenced to a room-temperature ultrastable cavity employing crystalline AlGaAs coatings with a fractional frequency instability of 4.2×10 −17 . This is one of the lowest for room-temperature systems and surpasses the limit imposed by Brownian noise if dielectric coatings were employed. To our knowledge, we identify for the first time in a room-temperature system, the spontaneous fluctuations of the coating birefringence as a leading contribution to frequency instability. At optimized conditions, the eigenfrequency of the cavity becomes highly immune to optical power fluctuations. Our work constrains any unknown coating noise to about half the amplitude of the Brownian noise of a dielectric coating, which confirms the potential of AlGaAs coatings for precision measurements at room temperature.

Authors

Publication Details

Journal
Optica
Published
2026-11-18
DOI
https://doi.org/10.1364/optica.610466
Citations
4
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
3.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Laser stabilized to a room-temperature cavity with AlGaAs coatings reaching 4.2 × 10 −17 fractional frequency instability

Thomas Legero, Daniele Nicolodi, F. Riehle, Sofia Herbers et al.
4 citations
Optica
Advanced Frequency and Time Standards
3.47
article

Laser stabilized to a room-temperature cavity with AlGaAs coatings reaching 4.2 × 10 −17 fractional frequency instability

Thomas Legero, Daniele Nicolodi, F. Riehle, Sofia Herbers, Steffen Sauer, Uwe Sterr, M Kempkes, Jialiang Yu, Chun Yu Ma
article en
4 citations

Abstract

We present a laser system referenced to a room-temperature ultrastable cavity employing crystalline AlGaAs coatings with a fractional frequency instability of 4.2×10 −17 . This is one of the lowest for room-temperature systems and surpasses the limit imposed by Brownian noise if dielectric coatings were employed. To our knowledge, we identify for the first time in a room-temperature system, the spontaneous fluctuations of the coating birefringence as a leading contribution to frequency instability. At optimized conditions, the eigenfrequency of the cavity becomes highly immune to optical power fluctuations. Our work constrains any unknown coating noise to about half the amplitude of the Brownian noise of a dielectric coating, which confirms the potential of AlGaAs coatings for precision measurements at room temperature.

OpticaVol. 13(12)
European Commission, Deutsche Forschungsgemeinschaft, RIKEN, European Metrology Programme for Innovation and Research
Openalex Percentile: Top 9%
Advanced Frequency and Time Standards
3.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon