Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study

OBJECTIVE Manual ventilation is a lifesaving intervention for children in respiratory arrest, yet the quality of pediatric ventilation delivered by emergency medical services (EMS) clinicians across geographically distinct sites is poorly characterized. We evaluated baseline EMS ventilation performance and whether a ventilation feedback device (VFD) improves adherence to national and international ventilation guidelines for ventilation rate, tidal volume, and mask seal. METHODS We conducted a single-anonymized, randomized, crossover study of EMS clinicians from 5 EMS agencies across 3 metropolitan sites in the United States. Using a simulated 3-year-old toddler manikin, participants completed 2 sequential 2-minute respiratory arrest scenarios separated by a 10-minute washout period. Participants performed ventilation with and without real-time VFD feedback in randomized order. The EOLifeX VFD recorded ventilation rate, tidal volume, and mask leak with each breath. Adherence to age-based guidelines was analyzed using generalized linear mixed-effects models with participants nested within sites. RESULTS We enrolled 123 participants across 5 agencies. With VFD feedback, guideline-recommended tidal volumes were achieved in 87% of breaths compared with 16.2% without feedback. Ventilation rate adherence improved from 65% to 88.6%. Mask leak of less than 30% occurred in 88.4% of ventilations with feedback vs 80% without feedback. CONCLUSION In our simulation study, EMS clinicians rarely met manual ventilation guidelines for pediatric patients in respiratory arrest. The use of a VFD substantially improved guideline adherence, suggesting broad potential to improve ventilation performance.

Authors

Institutions

Publication Details

Journal
PEDIATRICS
Published
2026-10-20
DOI
https://doi.org/10.1542/peds.2026-077291
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study

Fahd A. Ahmad, Jeffrey E. Siegler, Sang Hoon Lee, Lauren C. Riney et al.
PEDIATRICS
Cardiac Arrest and Resuscitation
article

Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study

Fahd A. Ahmad, Jeffrey E. Siegler, Sang Hoon Lee, Lauren C. Riney, Lorin R. Browne, Thomas Grawey, Debra Robinson, Joseph D Finney, Kavya John, Bradford McClain, Jinli Wang, Lynn Babcock
article en

Abstract

OBJECTIVE Manual ventilation is a lifesaving intervention for children in respiratory arrest, yet the quality of pediatric ventilation delivered by emergency medical services (EMS) clinicians across geographically distinct sites is poorly characterized. We evaluated baseline EMS ventilation performance and whether a ventilation feedback device (VFD) improves adherence to national and international ventilation guidelines for ventilation rate, tidal volume, and mask seal. METHODS We conducted a single-anonymized, randomized, crossover study of EMS clinicians from 5 EMS agencies across 3 metropolitan sites in the United States. Using a simulated 3-year-old toddler manikin, participants completed 2 sequential 2-minute respiratory arrest scenarios separated by a 10-minute washout period. Participants performed ventilation with and without real-time VFD feedback in randomized order. The EOLifeX VFD recorded ventilation rate, tidal volume, and mask leak with each breath. Adherence to age-based guidelines was analyzed using generalized linear mixed-effects models with participants nested within sites. RESULTS We enrolled 123 participants across 5 agencies. With VFD feedback, guideline-recommended tidal volumes were achieved in 87% of breaths compared with 16.2% without feedback. Ventilation rate adherence improved from 65% to 88.6%. Mask leak of less than 30% occurred in 88.4% of ventilations with feedback vs 80% without feedback. CONCLUSION In our simulation study, EMS clinicians rarely met manual ventilation guidelines for pediatric patients in respiratory arrest. The use of a VFD substantially improved guideline adherence, suggesting broad potential to improve ventilation performance.

PEDIATRICS
Children's Hospital of Wisconsin (US), Cincinnati Children's Hospital Medical Center (US), Medical College of Wisconsin (US), Washington University in St. Louis (US)
Openalex Percentile: Top 10%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.