Defining the Clinical Indication for Real‐Time Artificial Intelligence–Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy

Objectives To evaluate whether real‐time artificial intelligence (AI) breast ultrasound (US) can identify a subgroup of breast imaging reporting and data system (BI‐RADS) category 4A lesions without suspicious mammographic (MMG) findings in whom unnecessary biopsy may be safely avoided. Methods This retrospective analysis of single‐center biopsy registry included 641 consecutive US BI‐RADS 4A lesions that underwent vacuum‐assisted breast biopsy. Before conducting biopsy, the lesions were reassessed using a real‐time AI US system (CadAI‐B®), and MMG findings were classified as suspicious or non‐suspicious based on formal reports. Seven prespecified biopsy‐decision strategies were evaluated, including 3 AI‐only strategies, 3 mammography‐gated AI strategies, and the current standard strategy of biopsy all BI‐RADS 4A lesions. The primary outcomes were biopsy reduction rate, missed cancers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with final pathology as the reference standard. Results Among 641 cases of US BI‐RADS 4A lesions, 26 cases of malignancies (4.1%) were identified, including 14 cases of ductal carcinoma in situ (DCIS), 11 cases of invasive ductal carcinomas, and 1 case of apocrine carcinoma. AI reassigned 289 cases of lesions (45.1%) to BI‐RADS categories 1–3. AI‐only biopsy‐deferral strategies missed 30.8% and 38.5% of malignancies when biopsy was deferred for AI BI‐RADS ≤2 and ≤3 lesions, respectively, with DCIS accounting for most missed cancers. In contrast, among lesions without suspicious MMG findings, no malignancies were observed in AI BI‐RADS 1–3 lesions. The sequential strategy of deferring biopsy only for lesions with AI BI‐RADS ≤3 and non‐suspicious MMG findings reduced biopsies by 43.5% (279/641) while maintaining 100.0% sensitivity (95% CI, 87.1–100.0%) and increasing specificity to 45.4% (95% CI, 41.4–49.4%). Conclusion Real‐time AI breast US alone could not safely support biopsy deferral in US BI‐RADS 4A lesions. However, after suspicious MMG findings had been excluded, AI identified a low‐risk subgroup in whom unnecessary biopsy could be substantially reduced without compromising cancer detection. These findings suggest that the clinical utility of real‐time AI breast US lies in patients without suspicious MMG findings. Prospective multicenter validation is warranted before clinical implementation.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound in Medicine
Published
2026-10-18
DOI
https://doi.org/10.1002/jum.70439
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Defining the Clinical Indication for Real‐Time Artificial Intelligence–Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy

HAI LIN PARK, Bora Yang, Jaeil Kim, Joon Suk Moon et al.
Journal of Ultrasound in Medicine
AI in cancer detection
article

Defining the Clinical Indication for Real‐Time Artificial Intelligence–Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy

HAI LIN PARK, Bora Yang, Jaeil Kim, Joon Suk Moon, Byeongju Kang, Jeeyeon Lee, Won Hwa Kim, Ho Yong Park
article en

Abstract

Objectives To evaluate whether real‐time artificial intelligence (AI) breast ultrasound (US) can identify a subgroup of breast imaging reporting and data system (BI‐RADS) category 4A lesions without suspicious mammographic (MMG) findings in whom unnecessary biopsy may be safely avoided. Methods This retrospective analysis of single‐center biopsy registry included 641 consecutive US BI‐RADS 4A lesions that underwent vacuum‐assisted breast biopsy. Before conducting biopsy, the lesions were reassessed using a real‐time AI US system (CadAI‐B®), and MMG findings were classified as suspicious or non‐suspicious based on formal reports. Seven prespecified biopsy‐decision strategies were evaluated, including 3 AI‐only strategies, 3 mammography‐gated AI strategies, and the current standard strategy of biopsy all BI‐RADS 4A lesions. The primary outcomes were biopsy reduction rate, missed cancers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with final pathology as the reference standard. Results Among 641 cases of US BI‐RADS 4A lesions, 26 cases of malignancies (4.1%) were identified, including 14 cases of ductal carcinoma in situ (DCIS), 11 cases of invasive ductal carcinomas, and 1 case of apocrine carcinoma. AI reassigned 289 cases of lesions (45.1%) to BI‐RADS categories 1–3. AI‐only biopsy‐deferral strategies missed 30.8% and 38.5% of malignancies when biopsy was deferred for AI BI‐RADS ≤2 and ≤3 lesions, respectively, with DCIS accounting for most missed cancers. In contrast, among lesions without suspicious MMG findings, no malignancies were observed in AI BI‐RADS 1–3 lesions. The sequential strategy of deferring biopsy only for lesions with AI BI‐RADS ≤3 and non‐suspicious MMG findings reduced biopsies by 43.5% (279/641) while maintaining 100.0% sensitivity (95% CI, 87.1–100.0%) and increasing specificity to 45.4% (95% CI, 41.4–49.4%). Conclusion Real‐time AI breast US alone could not safely support biopsy deferral in US BI‐RADS 4A lesions. However, after suspicious MMG findings had been excluded, AI identified a low‐risk subgroup in whom unnecessary biopsy could be substantially reduced without compromising cancer detection. These findings suggest that the clinical utility of real‐time AI breast US lies in patients without suspicious MMG findings. Prospective multicenter validation is warranted before clinical implementation.

Journal of Ultrasound in Medicine
Kyungpook National University Hospital (KR), Kyungpook National University (KR), CHA University Gangnam Medical Center (KR)
Openalex Percentile: Top 13%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.