Seismic performance of timber mortise-tenon joints reinforced with a self-centering variable-friction damper

To improve the seismic performance of traditional timber mortise-and-tenon (M–T) joints, this study proposes a cylindrical self-centering variable-friction damper consisting of a steel casing, rubber friction elements, and a disc spring stack. The damper dissipates energy through displacement-dependent friction between the rubber elements and steel casing, while the disc spring stack provides restoring force. Low-cycle reversed loading tests, FE simulations, and retrofitting tests on straight-tenon and stepped-through-tenon joints were conducted to evaluate the damper performance and strengthening effectiveness. The effects of rubber hardness and length on the hysteretic behavior were investigated, and a simplified moment–rotation model was developed for strengthened joints. Results showed that the 80 Shore A rubber with a length of 50 mm exhibited the highest energy dissipation capacity, reaching 466.22 kN·mm per cycle at a displacement amplitude of 10 mm. The FE model reasonably reproduced the main hysteretic characteristics, with peak force errors below 19% and energy dissipation errors within 10%. Comparisons of the tested strengthened and unstrengthened specimen pairs indicated increases of 58.87% and 8.24% in initial stiffness, 43.57% and 192.18% in peak bending moment, and 27.13% and 42.37% in equivalent damping ratio, respectively, while residual pull-out displacements decreased by 23.5% and 28.0%. These results represent the comparative responses of the tested specimens due to the limited sample size. The proposed moment–rotation model reasonably describes the skeleton response of strengthened joints within the investigated rotation range of −0.15 rad to 0.15 rad, providing a simplified approach for describing the nonlinear rotational behavior of reinforced traditional timber joints.

Authors

Institutions

Publication Details

Journal
Structures
Published
2026-10-17
DOI
https://doi.org/10.1016/j.istruc.2026.113333
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance of timber mortise-tenon joints reinforced with a self-centering variable-friction damper

Chao Shuang, Wen Pan, Wanlin Cao, Zhencong Lai et al.
Structures
Seismic Performance and Analysis
article

Seismic performance of timber mortise-tenon joints reinforced with a self-centering variable-friction damper

Chao Shuang, Wen Pan, Wanlin Cao, Zhencong Lai, Yu Zhang, Tingting Chen
article en

Abstract

To improve the seismic performance of traditional timber mortise-and-tenon (M–T) joints, this study proposes a cylindrical self-centering variable-friction damper consisting of a steel casing, rubber friction elements, and a disc spring stack. The damper dissipates energy through displacement-dependent friction between the rubber elements and steel casing, while the disc spring stack provides restoring force. Low-cycle reversed loading tests, FE simulations, and retrofitting tests on straight-tenon and stepped-through-tenon joints were conducted to evaluate the damper performance and strengthening effectiveness. The effects of rubber hardness and length on the hysteretic behavior were investigated, and a simplified moment–rotation model was developed for strengthened joints. Results showed that the 80 Shore A rubber with a length of 50 mm exhibited the highest energy dissipation capacity, reaching 466.22 kN·mm per cycle at a displacement amplitude of 10 mm. The FE model reasonably reproduced the main hysteretic characteristics, with peak force errors below 19% and energy dissipation errors within 10%. Comparisons of the tested strengthened and unstrengthened specimen pairs indicated increases of 58.87% and 8.24% in initial stiffness, 43.57% and 192.18% in peak bending moment, and 27.13% and 42.37% in equivalent damping ratio, respectively, while residual pull-out displacements decreased by 23.5% and 28.0%. These results represent the comparative responses of the tested specimens due to the limited sample size. The proposed moment–rotation model reasonably describes the skeleton response of strengthened joints within the investigated rotation range of −0.15 rad to 0.15 rad, providing a simplified approach for describing the nonlinear rotational behavior of reinforced traditional timber joints.

StructuresVol. 94
Kunming University of Science and Technology (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.