Association between distance from the angle recess to the tube entry site and corneal endothelial cell loss after PreserFlo MicroShunt implantation

Abstract Purpose To investigate the association between anterior segment optical coherence tomography (AS-OCT)–derived tube parameters and corneal endothelial cell density (ECD) changes after PreserFlo MicroShunt (PMS) surgery in primary open-angle glaucoma (POAG) and exfoliation glaucoma (XFG). Study design Prospective cohort study. Methods This study included pseudophakic patients with POAG or XFG who underwent PMS implantation. ECD was measured preoperatively and at 1, 3, 6, and 12 months post operatively, and every 6 months thereafter. Intracameral tube parameters, including tube position and length, were assessed using AS-OCT images obtained 1 month postoperatively. Associations between OCT parameters and the monthly rate of ECD change (ECD slope) were evaluated using linear mixed-effects models. Results Mean preoperative ECD was 2384 ± 391 cells/mm 2 . Mean follow-up period was 15 ± 7 months, with 5.1 ± 1.3 ECD measurements per eye. Tube parameters did not differ significantly between POAG (67 eyes of 61 patients) and XFG (18 eyes of 16 patients). The mean ECD slope was −11.8 ± 2.2 cells/mm 2 /month in XFG and −9.8 ± 1.1 cells/mm 2 /month in POAG (p = 0.38). A greater distance from the angle recess to the intracameral tube entry site was significantly associated with a more negative ECD slope in both XFG and POAG groups (p = 0.02 and 0.03). Its contribution to ECD slope variance was greater in XFG than in POAG (R 2 = 0.243 vs. 0.069). Conclusion A longer distance from the angle recess to the intracameral tube entry site may predict accelerated ECD loss after PMS implantation, particularly in XFG.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Ophthalmology
Published
2026-10-17
DOI
https://doi.org/10.1007/s10384-026-01442-0
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association between distance from the angle recess to the tube entry site and corneal endothelial cell loss after PreserFlo MicroShunt implantation

Takahiro Minami, Takahiro Wada, Sachiko Udagawa, Tomomi Higashide et al.
Japanese Journal of Ophthalmology
Glaucoma and retinal disorders
article

Association between distance from the angle recess to the tube entry site and corneal endothelial cell loss after PreserFlo MicroShunt implantation

Takahiro Minami, Takahiro Wada, Sachiko Udagawa, Tomomi Higashide, Yoko Yamashita, Toshiya Suzuki, Shunsuke Nishimura
article en

Abstract

Abstract Purpose To investigate the association between anterior segment optical coherence tomography (AS-OCT)–derived tube parameters and corneal endothelial cell density (ECD) changes after PreserFlo MicroShunt (PMS) surgery in primary open-angle glaucoma (POAG) and exfoliation glaucoma (XFG). Study design Prospective cohort study. Methods This study included pseudophakic patients with POAG or XFG who underwent PMS implantation. ECD was measured preoperatively and at 1, 3, 6, and 12 months post operatively, and every 6 months thereafter. Intracameral tube parameters, including tube position and length, were assessed using AS-OCT images obtained 1 month postoperatively. Associations between OCT parameters and the monthly rate of ECD change (ECD slope) were evaluated using linear mixed-effects models. Results Mean preoperative ECD was 2384 ± 391 cells/mm 2 . Mean follow-up period was 15 ± 7 months, with 5.1 ± 1.3 ECD measurements per eye. Tube parameters did not differ significantly between POAG (67 eyes of 61 patients) and XFG (18 eyes of 16 patients). The mean ECD slope was −11.8 ± 2.2 cells/mm 2 /month in XFG and −9.8 ± 1.1 cells/mm 2 /month in POAG (p = 0.38). A greater distance from the angle recess to the intracameral tube entry site was significantly associated with a more negative ECD slope in both XFG and POAG groups (p = 0.02 and 0.03). Its contribution to ECD slope variance was greater in XFG than in POAG (R 2 = 0.243 vs. 0.069). Conclusion A longer distance from the angle recess to the intracameral tube entry site may predict accelerated ECD loss after PMS implantation, particularly in XFG.

Japanese Journal of Ophthalmology
Kanazawa University (JP)
Good health and well-being
Openalex Percentile: Top 9%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.