Validating a Wearable Bluetooth Oximeter for Infants in the Neonatal Intensive Care Unit

ABSTRACT Introduction Oxygen is vital for life but the wrong amount of oxygen can lead to significant risk of morbidity and mortality. Preterm infants are at particular risk from both too little (hypoxia) and excess (hyperoxia) oxygen. In the neonatal intensive care unit (NICU), oxygen treatment is guided by oximetry derived from wired oximeters which are difficult to use outside of the hospital environment. We aimed to validate Bluetooth wireless oximeters in newborn infants to determine the accuracy of devices that would be more suitable for out of hospital use. Methods Three 20 min sets of measurements including oxygen saturations (SpO 2 ), heart rate (HR) and perfusion index (PI) from the post‐ductal regions (left arm and lower limbs) were conducted in 21 spontaneously ventilating infants using the Masimo (1) SafetyNet and (2) Radical 7 oximeters. The wired Radical 7 oximeter was the reference. Data were downloaded onto CSV files and analysed for agreement. Results Twenty‐one (eight male) infants were recruited between July to September 2023. Median gestations and ages were 36 weeks and 3 days. Neither Bluetooth device (SafetyNet and wireless Radical 7) met International Organization for Standardization (ISO) standard (ARMSE ≤ 3%), Score 3.624 (wireless Rad‐7) and 3.884 (SafetyNet). Both wearables consistently overestimated SpO 2 , with mean biases (wired‐wearable) of −1.802 (Rad‐7) and −1.803 (SafetyNet), that increased at lower SpO 2 levels. Linear regression, ICC, Pearson's correlation analyses showed poor consistency. Conclusion Wireless oximeters have poor correlation with wired oximeters especially at lower SpO 2 levels but ease of use, especially in the home environment in less acutely ill patients, requires further evaluation.

Authors

Institutions

Publication Details

Journal
Journal of Paediatrics and Child Health
Published
2026-10-16
DOI
https://doi.org/10.1111/jpc.70622
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validating a Wearable Bluetooth Oximeter for Infants in the Neonatal Intensive Care Unit

AMY COURTNEY, Ju Lee Oei
Journal of Paediatrics and Child Health
Non-Invasive Vital Sign Monitoring
article

Validating a Wearable Bluetooth Oximeter for Infants in the Neonatal Intensive Care Unit

AMY COURTNEY, Ju Lee Oei
article en

Abstract

ABSTRACT Introduction Oxygen is vital for life but the wrong amount of oxygen can lead to significant risk of morbidity and mortality. Preterm infants are at particular risk from both too little (hypoxia) and excess (hyperoxia) oxygen. In the neonatal intensive care unit (NICU), oxygen treatment is guided by oximetry derived from wired oximeters which are difficult to use outside of the hospital environment. We aimed to validate Bluetooth wireless oximeters in newborn infants to determine the accuracy of devices that would be more suitable for out of hospital use. Methods Three 20 min sets of measurements including oxygen saturations (SpO 2 ), heart rate (HR) and perfusion index (PI) from the post‐ductal regions (left arm and lower limbs) were conducted in 21 spontaneously ventilating infants using the Masimo (1) SafetyNet and (2) Radical 7 oximeters. The wired Radical 7 oximeter was the reference. Data were downloaded onto CSV files and analysed for agreement. Results Twenty‐one (eight male) infants were recruited between July to September 2023. Median gestations and ages were 36 weeks and 3 days. Neither Bluetooth device (SafetyNet and wireless Radical 7) met International Organization for Standardization (ISO) standard (ARMSE ≤ 3%), Score 3.624 (wireless Rad‐7) and 3.884 (SafetyNet). Both wearables consistently overestimated SpO 2 , with mean biases (wired‐wearable) of −1.802 (Rad‐7) and −1.803 (SafetyNet), that increased at lower SpO 2 levels. Linear regression, ICC, Pearson's correlation analyses showed poor consistency. Conclusion Wireless oximeters have poor correlation with wired oximeters especially at lower SpO 2 levels but ease of use, especially in the home environment in less acutely ill patients, requires further evaluation.

Journal of Paediatrics and Child Health
The University of Sydney (AU), Royal Hospital for Women (AU), UNSW Sydney (AU)
Openalex Percentile: Top 24%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.