Polarization Sensitive Optical Coherence Tomography for Surgical Margin Assessment for Canine Soft Tissue Sarcoma

Soft tissue sarcomas (STSs) and skeletal muscle both appear high scattering on spectral-domain optical coherence tomography (SD-OCT) imaging, which resulted in instances of misclassification by observers in prior soft tissue sarcoma margin assessment studies. Polarization-sensitive optical coherence tomography (PS-OCT) is an extension of OCT that provides additional information about tissue polarization contrast. In this prospective study we wanted to evaluate whether PS-OCT improves tissue differentiation and diagnostic accuracy compared to spectral-domain OCT (SD-OCT) alone. PS-OCT images from surgical margins of 10 resected STS were compared with histopathology to identify characteristic features of normal and neoplastic tissues. Then, six observers of varying OCT image interpretation experience assessed surgical margins from 30 resected STS using SD-OCT alone and SD-OCT combined with PS-OCT. PS-OCT images demonstrated distinct birefringence (optical patterns), corresponding to tissue organization: skeletal muscle exhibited alternating high and low birefringence bands, fascia showed variable birefringence and STS had uniformly low birefringence. Overall diagnostic accuracy was high for both modalities [correct classification rate: SD-OCT alone 93.7% (95% confidence interval (CI): 90.1, 96.0) vs. SD-OCT combined with PS-OCT 92.6% (95% = CI: 89.3, 95.4)]; adding PS-OCT did not significantly improve accuracy across all observers (p = 0.82), though expert observers benefited significantly (p = 0.0018). Interobserver and intraobserver agreement ranged from substantial to near perfect. These findings suggest PS-OCT can be interpreted reliably after brief training and may enhance accuracy for experienced users. Further research should explore structured training and real-time applications for comprehensive surgical margin evaluation.

Authors

Institutions

Publication Details

Journal
Veterinary and Comparative Oncology
Published
2026-10-15
DOI
https://doi.org/10.1111/vco.70121
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polarization Sensitive Optical Coherence Tomography for Surgical Margin Assessment for Canine Soft Tissue Sarcoma

Nikesh K. Patel, Josephine A. Dornbusch, Gabrielle S. Fontes, Morgan R. Biggo et al.
Veterinary and Comparative Oncology
Optical Coherence Tomography Applications
article

Polarization Sensitive Optical Coherence Tomography for Surgical Margin Assessment for Canine Soft Tissue Sarcoma

Nikesh K. Patel, Josephine A. Dornbusch, Gabrielle S. Fontes, Morgan R. Biggo, Laura Elizabeth Selmic, Ryan N. Jennings, Andrea K. Erickson, Natalia Jurcak, Yi‐Fan Shen, Jorge Santana Mignucci, Hannah Weaver
article en

Abstract

Soft tissue sarcomas (STSs) and skeletal muscle both appear high scattering on spectral-domain optical coherence tomography (SD-OCT) imaging, which resulted in instances of misclassification by observers in prior soft tissue sarcoma margin assessment studies. Polarization-sensitive optical coherence tomography (PS-OCT) is an extension of OCT that provides additional information about tissue polarization contrast. In this prospective study we wanted to evaluate whether PS-OCT improves tissue differentiation and diagnostic accuracy compared to spectral-domain OCT (SD-OCT) alone. PS-OCT images from surgical margins of 10 resected STS were compared with histopathology to identify characteristic features of normal and neoplastic tissues. Then, six observers of varying OCT image interpretation experience assessed surgical margins from 30 resected STS using SD-OCT alone and SD-OCT combined with PS-OCT. PS-OCT images demonstrated distinct birefringence (optical patterns), corresponding to tissue organization: skeletal muscle exhibited alternating high and low birefringence bands, fascia showed variable birefringence and STS had uniformly low birefringence. Overall diagnostic accuracy was high for both modalities [correct classification rate: SD-OCT alone 93.7% (95% confidence interval (CI): 90.1, 96.0) vs. SD-OCT combined with PS-OCT 92.6% (95% = CI: 89.3, 95.4)]; adding PS-OCT did not significantly improve accuracy across all observers (p = 0.82), though expert observers benefited significantly (p = 0.0018). Interobserver and intraobserver agreement ranged from substantial to near perfect. These findings suggest PS-OCT can be interpreted reliably after brief training and may enhance accuracy for experienced users. Further research should explore structured training and real-time applications for comprehensive surgical margin evaluation.

Veterinary and Comparative Oncology
The Ohio State University (US), University of Missouri (US)
Openalex Percentile: Top 24%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.