Temperature Distribution and Vertical Stratification near Side-Wall Inlets of Stacked Cage Broiler Houses in Winter

Inlet design assumes that supply air from side-wall inlets mixes with house air over several metres, but whether this holds in a densely caged multi-tier house, where cages and birds obstruct the jet, is untested. The bird-zone environment of a commercial stacked-cage house was measured with 24 in-cage sensors at three distances and two tiers over ten winter days. Three of four groups showed no resolvable cooling gradient at 1.5 m; only one north-side group cooled with distance, strengthening with ventilation (0.30 K per percent, R2 = 0.39), while another showed the opposite sign. Every fitted decay coefficient (αdh=0 to 0.004) lay below the free-jet design range (0.01–0.03), by five or more times over the window. Vertical stratification of 0.78 K dominated (side × tier p<0.001): the upper tier was up to 2.4 K warmer on the north side, while the south-side tiers differed by under 0.5 K. Shading nets lowered north-side inlet temperature by 0.80 K but warmed the south side. The practical consequence is that the thermal environment is organised by tier and side rather than by near-inlet distance, so monitoring, control and welfare-oriented assessment should target tiers and sides.

Authors

Institutions

Publication Details

Journal
Veterinary Sciences
Published
2026-10-16
DOI
https://doi.org/10.3390/vetsci13101103
Primary Topic
Effects of Environmental Stressors on Livestock
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature Distribution and Vertical Stratification near Side-Wall Inlets of Stacked Cage Broiler Houses in Winter

Bin Xu, Yongxiang Wei, Shaoyu Li, Quanyou Sun et al.
Veterinary Sciences
Effects of Environmental Stressors on Livestock
article

Temperature Distribution and Vertical Stratification near Side-Wall Inlets of Stacked Cage Broiler Houses in Winter

Bin Xu, Yongxiang Wei, Shaoyu Li, Quanyou Sun, Wenjia Li
article en

Abstract

Inlet design assumes that supply air from side-wall inlets mixes with house air over several metres, but whether this holds in a densely caged multi-tier house, where cages and birds obstruct the jet, is untested. The bird-zone environment of a commercial stacked-cage house was measured with 24 in-cage sensors at three distances and two tiers over ten winter days. Three of four groups showed no resolvable cooling gradient at 1.5 m; only one north-side group cooled with distance, strengthening with ventilation (0.30 K per percent, R2 = 0.39), while another showed the opposite sign. Every fitted decay coefficient (αdh=0 to 0.004) lay below the free-jet design range (0.01–0.03), by five or more times over the window. Vertical stratification of 0.78 K dominated (side × tier p<0.001): the upper tier was up to 2.4 K warmer on the north side, while the south-side tiers differed by under 0.5 K. Shading nets lowered north-side inlet temperature by 0.80 K but warmed the south side. The practical consequence is that the thermal environment is organised by tier and side rather than by near-inlet distance, so monitoring, control and welfare-oriented assessment should target tiers and sides.

Veterinary SciencesVol. 13(10)
Henan Academy of Agricultural Sciences (CN)
Henan Academy of Agricultural Sciences
Openalex Percentile: Top 15%
Effects of Environmental Stressors on Livestock
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.