FAMSA-Net: frequency-aware multi-scale spatial attention network for gain quality grading in automated breast ultrasound images

Gain setting affects Automated Breast Ultrasound (ABUS) image brightness and contrast, inappropriate gain may obscure lesion boundaries, alter tissue echogenicity, and degrade clinical interpretation. Current gain adjustment relies heavily on operator experience, resulting in intra- and inter-operator variability. This study aims to develop an automated and objective gain quality grading framework for ABUS images to reduce subjective variability and facilitate standardized image acquisition. A large-scale ABUS dataset comprising 31,628 images was collected from Yunnan Cancer Hospital, including five gain quality categories: Insufficient, Low, Optimal, High, and Excessive. Frequency-aware Multi-scale Spatial Attention Network (FAMSA-Net) was proposed for gain quality grading. Gain-discriminative residual blocks and a Multi-Scale Gain Fusion (MSGF) module were designed to capture gain-sensitive characteristics across multiple feature scales. In addition, we integrate Frequency-Domain Enhancement (FDE) to amplify gain-related frequency cues, Spatial Transformer Networks (STN) to spatially align breast anatomical structures, and Context-Aware Pooling (CAP) to adaptively aggregate contextual information. Experimental results demonstrated that FAMSA-Net achieved an accuracy of 95.49%, outperforming DenseNet121 (91.30%) and EfficientNetB3 (89.93%) by 4.19% and 5.56%. FAMSA-Net uses 16.58 M parameters and 4.34 GFLOPs, which is more efficient than DenseNet121 and EfficientNetB3. Ablation experiments showed that removing STN caused the largest accuracy drop, from 95.49% to 83.76%. In contrast, under the GAP pooling setting, removing FDE or MSGF improved accuracy to 90.77% and 90.01%, suggesting that the module contributions are not additive. Furthermore, the full model reached its peak accuracy of 95.49% after replacing GAP with CAP, indicating the importance of contextual aggregation for effective module cooperation.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-10-16
DOI
https://doi.org/10.1186/s12880-026-02861-8
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FAMSA-Net: frequency-aware multi-scale spatial attention network for gain quality grading in automated breast ultrasound images

Bingbing He, Wenbing Lv, Yufeng Zhang, Tongxing Pu et al.
BMC Medical Imaging
AI in cancer detection
article

FAMSA-Net: frequency-aware multi-scale spatial attention network for gain quality grading in automated breast ultrasound images

Bingbing He, Wenbing Lv, Yufeng Zhang, Tongxing Pu, Mengxia Li, Zhiyao Li, X. Allen Li
article en

Abstract

Gain setting affects Automated Breast Ultrasound (ABUS) image brightness and contrast, inappropriate gain may obscure lesion boundaries, alter tissue echogenicity, and degrade clinical interpretation. Current gain adjustment relies heavily on operator experience, resulting in intra- and inter-operator variability. This study aims to develop an automated and objective gain quality grading framework for ABUS images to reduce subjective variability and facilitate standardized image acquisition. A large-scale ABUS dataset comprising 31,628 images was collected from Yunnan Cancer Hospital, including five gain quality categories: Insufficient, Low, Optimal, High, and Excessive. Frequency-aware Multi-scale Spatial Attention Network (FAMSA-Net) was proposed for gain quality grading. Gain-discriminative residual blocks and a Multi-Scale Gain Fusion (MSGF) module were designed to capture gain-sensitive characteristics across multiple feature scales. In addition, we integrate Frequency-Domain Enhancement (FDE) to amplify gain-related frequency cues, Spatial Transformer Networks (STN) to spatially align breast anatomical structures, and Context-Aware Pooling (CAP) to adaptively aggregate contextual information. Experimental results demonstrated that FAMSA-Net achieved an accuracy of 95.49%, outperforming DenseNet121 (91.30%) and EfficientNetB3 (89.93%) by 4.19% and 5.56%. FAMSA-Net uses 16.58 M parameters and 4.34 GFLOPs, which is more efficient than DenseNet121 and EfficientNetB3. Ablation experiments showed that removing STN caused the largest accuracy drop, from 95.49% to 83.76%. In contrast, under the GAP pooling setting, removing FDE or MSGF improved accuracy to 90.77% and 90.01%, suggesting that the module contributions are not additive. Furthermore, the full model reached its peak accuracy of 95.49% after replacing GAP with CAP, indicating the importance of contextual aggregation for effective module cooperation.

BMC Medical Imaging
Yunnan University (CN), Kunming Medical University (CN), Nanjing Institute of Railway Technology (CN), Dianchi College, Nanjing Medical University (CN)
Good health and well-being
Openalex Percentile: Top 13%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.