The Influence of Different Distance Sampling Step Sizes on the Accuracy of Neural Network-Based Magnetic Distance Measurement

Achieving high accuracy in neural network-based magnetic distance measurement depends critically on the spatial sampling step sizes of the training data and the number of deployed sensors. This paper systematically investigates how these two distinct factors influence the prediction accuracy of deep neural networks (DNNs). Utilizing Ansys finite element simulations of a permanent magnet translating over a 140 mm range, it is found that finer sampling steps drastically improve DNN precision. Specifically, decreasing the sampling step from 0.5 mm to 0.005 mm for a single-sensor system reduces the mean absolute error (MAE) from 0.9405 mm to 0.0503 mm. Furthermore, expanding the setup to a three-sensor array under identical conditions further suppresses the simulated MAE from 0.2407 mm to 0.0016 mm. Empirical experiments subsequently validated these theoretical findings. Notably, the physical three-sensor setup achieved a minimum MAE of 1.1881 mm at the finest step size, which represents a marked improvement over the 1.6065 mm error observed in the single-sensor system. These results confirm that both a sufficient sample size and multiple sensors enhance distance measurement accuracy.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-16
DOI
https://doi.org/10.3390/s26206583
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of Different Distance Sampling Step Sizes on the Accuracy of Neural Network-Based Magnetic Distance Measurement

Qiao Qi, 朱华辰, Xiumei Li, Zhenghong Qian et al.
Sensors
Magnetic Field Sensors Techniques
article

The Influence of Different Distance Sampling Step Sizes on the Accuracy of Neural Network-Based Magnetic Distance Measurement

Qiao Qi, 朱华辰, Xiumei Li, Zhenghong Qian, Ru Bai, Shihan Wang, Chaoyi Qiu, Zhe Sheng
article en

Abstract

Achieving high accuracy in neural network-based magnetic distance measurement depends critically on the spatial sampling step sizes of the training data and the number of deployed sensors. This paper systematically investigates how these two distinct factors influence the prediction accuracy of deep neural networks (DNNs). Utilizing Ansys finite element simulations of a permanent magnet translating over a 140 mm range, it is found that finer sampling steps drastically improve DNN precision. Specifically, decreasing the sampling step from 0.5 mm to 0.005 mm for a single-sensor system reduces the mean absolute error (MAE) from 0.9405 mm to 0.0503 mm. Furthermore, expanding the setup to a three-sensor array under identical conditions further suppresses the simulated MAE from 0.2407 mm to 0.0016 mm. Empirical experiments subsequently validated these theoretical findings. Notably, the physical three-sensor setup achieved a minimum MAE of 1.1881 mm at the finest step size, which represents a marked improvement over the 1.6065 mm error observed in the single-sensor system. These results confirm that both a sufficient sample size and multiple sensors enhance distance measurement accuracy.

SensorsVol. 26(20)
Hangzhou Normal University (CN), Joyson Electronics (China) (CN), Hangzhou Dianzi University (CN)
National Natural Science Foundation of China, Hangzhou Normal University, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 23%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.