Computational Modeling and 1D-CNN-Assisted Optimization of a Cu/ZnO/Si/MXene Multilayer SPR Biosensor for High-Sensitivity Multi-Analyte Detection

Cancer biomarkers, glucose molecules, and low-refractive-index analytes require sensitive and reliable optical sensing platforms. This study proposes a structurally optimized surface plasmon resonance (SPR) biosensor developed using COMSOL Multiphysics, where multilayer structural parameters are systematically varied to enhance electromagnetic-field confinement and resonance tuning. A onedimensional convolutional neural network (1D-CNN) is integrated to predict sensor performance under varying structural conditions. The optimized sensor demonstrates stable resonance behavior across a refractive-index range of 1.36–1.401 RIU, achieving a maximum angular sensitivity of 480°/RIU, a peak figure of merit (FOM) of 93 RIU -1 , and quality factors ranging from 10.301 to 11.370. Strong plasmonic coupling occurs at 79°, confirming enhanced light–matter interaction at the sensor–analyte interface. A highly linear resonance-angle response is obtained with R 2 > 0.98 and minimal prediction error. Overall, the proposed platform offers high sensitivity, stable performance, and machine-learningassisted optimization for diverse analyte detection.

Authors

Publication Details

Journal
International Journal of Computational Materials Science and Engineering
Published
2026-10-15
DOI
https://doi.org/10.1142/s2047684126500326
Primary Topic
Plasmonic and Surface Plasmon Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational Modeling and 1D-CNN-Assisted Optimization of a Cu/ZnO/Si/MXene Multilayer SPR Biosensor for High-Sensitivity Multi-Analyte Detection

U. Arun Kumar, V. Kalaipoonguzhali, Sandeep Prabhu, Kumaravel Kaliaperumal et al.
International Journal of Computational Materials Science and Engineering
Plasmonic and Surface Plasmon Research
article

Computational Modeling and 1D-CNN-Assisted Optimization of a Cu/ZnO/Si/MXene Multilayer SPR Biosensor for High-Sensitivity Multi-Analyte Detection

U. Arun Kumar, V. Kalaipoonguzhali, Sandeep Prabhu, Kumaravel Kaliaperumal, V. Gomathy
article en

Abstract

Cancer biomarkers, glucose molecules, and low-refractive-index analytes require sensitive and reliable optical sensing platforms. This study proposes a structurally optimized surface plasmon resonance (SPR) biosensor developed using COMSOL Multiphysics, where multilayer structural parameters are systematically varied to enhance electromagnetic-field confinement and resonance tuning. A onedimensional convolutional neural network (1D-CNN) is integrated to predict sensor performance under varying structural conditions. The optimized sensor demonstrates stable resonance behavior across a refractive-index range of 1.36–1.401 RIU, achieving a maximum angular sensitivity of 480°/RIU, a peak figure of merit (FOM) of 93 RIU -1 , and quality factors ranging from 10.301 to 11.370. Strong plasmonic coupling occurs at 79°, confirming enhanced light–matter interaction at the sensor–analyte interface. A highly linear resonance-angle response is obtained with R 2 > 0.98 and minimal prediction error. Overall, the proposed platform offers high sensitivity, stable performance, and machine-learningassisted optimization for diverse analyte detection.

International Journal of Computational Materials Science and Engineering
Openalex Percentile: Top 24%
Plasmonic and Surface Plasmon Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.