Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review

A BSTRACT The urethral plate (UP) and glans width (GW) are important determinants of outcomes following distal hypospadias repair, but considerable variability exists in their measurement and interpretation. We conducted a systematic review according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 statement, searching PubMed/MEDLINE, Embase, Cochrane CENTRAL, Web of Science, Scopus, and Google Scholar for studies published between January 2004 and December 2024 reporting UP and/or GW measurements in children undergoing hypospadias repair. Two reviewers independently extracted the data. To address variability in UP measurement, we standardized assessment at the narrowest glanular segment, designated the “B point,” to define the B-Urethral Plate (B-UP) measurement. Fourteen studies involving 1348 patients were included. Mean reported UP width ranged from 4.8 ± 1.3 mm to 7.3 ± 0.5 mm, while mean GW ranged from 9.5 ± 1.6 mm to 10.4 ± 2.2 mm. Reported complication rates ranged from 0% to 35% and appeared higher with narrower UPs (<6–8 mm) and smaller GW (<14 mm). Based on these findings, we propose a B-UP/GW-based surgical framework: B-UP >8 mm with GW >14 mm, Thiersch–Duplay repair; B-UP 6–8 mm with GW ≥14 mm, tubularized incised plate (TIP) repair; B-UP <6 mm with GW >14 mm, grafted TIP; and B-UP <6 mm with GW <14 mm, onlay or Mathieu repair. These thresholds are intended as pragmatic ranges rather than definitive clinical cutoffs. The proposed B-UP/GW framework may provide a more objective and reproducible approach to surgical planning and outcome reporting in distal hypospadias, but prospective multicentre validation is required before routine clinical adoption.

Authors

Institutions

Publication Details

Journal
Journal of Indian Association of Pediatric Surgeons
Published
2026-10-15
DOI
https://doi.org/10.4103/jiaps.jiaps_252_26
Primary Topic
Urological Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review

Ramesh Babu, Vikesh Agrawal
Journal of Indian Association of Pediatric Surgeons
Urological Disorders and Treatments
article

Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review

Ramesh Babu, Vikesh Agrawal
article en

Abstract

A BSTRACT The urethral plate (UP) and glans width (GW) are important determinants of outcomes following distal hypospadias repair, but considerable variability exists in their measurement and interpretation. We conducted a systematic review according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 statement, searching PubMed/MEDLINE, Embase, Cochrane CENTRAL, Web of Science, Scopus, and Google Scholar for studies published between January 2004 and December 2024 reporting UP and/or GW measurements in children undergoing hypospadias repair. Two reviewers independently extracted the data. To address variability in UP measurement, we standardized assessment at the narrowest glanular segment, designated the “B point,” to define the B-Urethral Plate (B-UP) measurement. Fourteen studies involving 1348 patients were included. Mean reported UP width ranged from 4.8 ± 1.3 mm to 7.3 ± 0.5 mm, while mean GW ranged from 9.5 ± 1.6 mm to 10.4 ± 2.2 mm. Reported complication rates ranged from 0% to 35% and appeared higher with narrower UPs (<6–8 mm) and smaller GW (<14 mm). Based on these findings, we propose a B-UP/GW-based surgical framework: B-UP >8 mm with GW >14 mm, Thiersch–Duplay repair; B-UP 6–8 mm with GW ≥14 mm, tubularized incised plate (TIP) repair; B-UP <6 mm with GW >14 mm, grafted TIP; and B-UP <6 mm with GW <14 mm, onlay or Mathieu repair. These thresholds are intended as pragmatic ranges rather than definitive clinical cutoffs. The proposed B-UP/GW framework may provide a more objective and reproducible approach to surgical planning and outcome reporting in distal hypospadias, but prospective multicentre validation is required before routine clinical adoption.

Journal of Indian Association of Pediatric Surgeons
Sri Ramachandra Institute of Higher Education and Research (IN), Netaji Subhash Chandra Bose Medical College (IN)
Openalex Percentile: Top 9%
Urological Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.