Case-level audit of thyroid ultrasound and cytology deep learning: label conflicts, split design, and shortcut-sensitive performance in a public archive

The measured performance of thyroid imaging artificial intelligence depends on how the analytical population is assembled, how images are partitioned, whether non-anatomical image content is informative, and which reference labels are used. We audited a public multimodal thyroid archive at case level and examined what its reported performance does and does not demonstrate. The released archive of Pang et al. (387 ultrasound images; 1,332 fine-needle aspiration cytology blocks) was audited for exact and near-duplicate images and for contradictory labels, and a frozen case-level partition was built. Five ImageNet-initialised backbones and their mean-probability ensemble were evaluated by group-stratified five-fold cross-validation and on the frozen test set, with thresholds selected on validation data and case-clustered 95% confidence intervals. Revision-stage control analyses comprised an identical-code comparison of image-level and case-grouped folds; retraining with a heuristically detected sonographic sector or its surround removed, for all five backbones and the ensemble; and a metadata-only model without a convolutional network. Frozen ultrasound models were then reassessed on TN3K, against its distributed benign/malignant labels, and on DDTI, for concordance with TI-RADS categories; both datasets had been accessed during earlier analytical development. Nine ultrasound images appeared under both benign and papillary carcinoma labels (19 files) and were excluded. Under case-level cross-validation, the cytology ensemble reached an AUROC of 0.958 (95% CI 0.938–0.975) and the ultrasound ensemble 0.768 (0.716–0.819). Image-level folds, despite 99.8% within-fold case contamination, changed AUROC by −0.002 (−0.021 to 0.019) and +0.019 (0.008 to 0.032) for the two tested backbones. After removal of the detected sonographic sector, the ultrasound ensemble retained an AUROC of 0.690 (0.630–0.747), a paired change of −0.078 (−0.148 to −0.013); with only the detected sector retained, it reached 0.760 (paired change −0.008, −0.054 to 0.039). Sector detection fell back to a fixed central box in 24.2% of frames. A metadata-only model using frame geometry, global intensity and border statistics reached 0.749 (0.692–0.804) for ultrasound. In post-exposure reassessment, the ensemble reached 0.700 (0.661–0.741; image-level interval) on TN3K and over-predicted malignancy (calibration-in-the-large −0.49), and showed no concordance with DDTI TI-RADS grouping (0.518, 0.436–0.605). This case-level audit of a public thyroid archive showed contradictory labels, partition-sensitive evaluation, and substantial discriminative signal both after removal of a heuristically detected sonographic region and in acquisition metadata alone, so performance on this archive cannot be interpreted as exclusively lesion-based. Post-exposure reassessment on external datasets showed limited and endpoint-dependent transport of the internal models.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-10-16
DOI
https://doi.org/10.1186/s12880-026-02944-6
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case-level audit of thyroid ultrasound and cytology deep learning: label conflicts, split design, and shortcut-sensitive performance in a public archive

Behnam Kiani Kalejahi, Mohammad Javad Rajabi
BMC Medical Imaging
AI in cancer detection
article

Case-level audit of thyroid ultrasound and cytology deep learning: label conflicts, split design, and shortcut-sensitive performance in a public archive

Behnam Kiani Kalejahi, Mohammad Javad Rajabi
article en

Abstract

The measured performance of thyroid imaging artificial intelligence depends on how the analytical population is assembled, how images are partitioned, whether non-anatomical image content is informative, and which reference labels are used. We audited a public multimodal thyroid archive at case level and examined what its reported performance does and does not demonstrate. The released archive of Pang et al. (387 ultrasound images; 1,332 fine-needle aspiration cytology blocks) was audited for exact and near-duplicate images and for contradictory labels, and a frozen case-level partition was built. Five ImageNet-initialised backbones and their mean-probability ensemble were evaluated by group-stratified five-fold cross-validation and on the frozen test set, with thresholds selected on validation data and case-clustered 95% confidence intervals. Revision-stage control analyses comprised an identical-code comparison of image-level and case-grouped folds; retraining with a heuristically detected sonographic sector or its surround removed, for all five backbones and the ensemble; and a metadata-only model without a convolutional network. Frozen ultrasound models were then reassessed on TN3K, against its distributed benign/malignant labels, and on DDTI, for concordance with TI-RADS categories; both datasets had been accessed during earlier analytical development. Nine ultrasound images appeared under both benign and papillary carcinoma labels (19 files) and were excluded. Under case-level cross-validation, the cytology ensemble reached an AUROC of 0.958 (95% CI 0.938–0.975) and the ultrasound ensemble 0.768 (0.716–0.819). Image-level folds, despite 99.8% within-fold case contamination, changed AUROC by −0.002 (−0.021 to 0.019) and +0.019 (0.008 to 0.032) for the two tested backbones. After removal of the detected sonographic sector, the ultrasound ensemble retained an AUROC of 0.690 (0.630–0.747), a paired change of −0.078 (−0.148 to −0.013); with only the detected sector retained, it reached 0.760 (paired change −0.008, −0.054 to 0.039). Sector detection fell back to a fixed central box in 24.2% of frames. A metadata-only model using frame geometry, global intensity and border statistics reached 0.749 (0.692–0.804) for ultrasound. In post-exposure reassessment, the ensemble reached 0.700 (0.661–0.741; image-level interval) on TN3K and over-predicted malignancy (calibration-in-the-large −0.49), and showed no concordance with DDTI TI-RADS grouping (0.518, 0.436–0.605). This case-level audit of a public thyroid archive showed contradictory labels, partition-sensitive evaluation, and substantial discriminative signal both after removal of a heuristically detected sonographic region and in acquisition metadata alone, so performance on this archive cannot be interpreted as exclusively lesion-based. Post-exposure reassessment on external datasets showed limited and endpoint-dependent transport of the internal models.

BMC Medical Imaging
INTI International University (MY), Central Asian University (UZ)
Good health and well-being
Openalex Percentile: Top 13%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.