Evaluating Explicit Anatomical Priors Beyond a Mature CT Detector for Six Acute Abdominal Emergencies

Abstract To test whether anatomical priors from a general-purpose organ segmentation model (TotalSegmentator, TS), applied at inference or during training, improve an externally validated YOLOv11 detector for six acute abdominal emergencies. The frozen detector was applied to 827 external Stanford Merlin CT studies with language-model report labels; a nested 280-study radiologist-adjudicated subset was the reference standard. TS-derived slice selection (Arm A), organ-state integration (Arm B), and their combination (Arm C) were compared with the detector alone under frozen, recalibrated, and fine-tuned conditions. The detector was also retrained from scratch (identical 10-epoch budget) with image channels only, with the patient’s TS organ maps as added input channels, or with another patient’s maps. AUROC was primary; comparisons used a paired study-level bootstrap. The detector generalized externally (macro AUROC 0.816 cohort; 0.879 adjudicated). Slice selection was non-inferior but not beneficial: nearly all confident detections already lay within the anchored organ’s axial range; organ-state fusion improved AUROC only for cholecystitis (hypothesis-generating). In single runs, training with organ maps raised internal test [email protected] (0.517 versus 0.482), and the model depended on the maps, but external macro AUROC did not improve (0.822 versus 0.829; $$\Delta $$ Δ −0.007, 95% CI −0.019 to +0.007) and kidney-stone AUROC fell (0.678 versus 0.768; exploratory), unlike with another patient’s maps. Per-site recalibration was the most effective operating-point adjustment (macro F1 +0.021); annotation-free fine-tuning reduced discrimination. Explicit anatomy, applied after detection or during training, did not improve this detector’s overall external discrimination. Per-site recalibration gave the largest operating-point gain.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-10-16
DOI
https://doi.org/10.1007/s10278-026-02368-2
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Explicit Anatomical Priors Beyond a Mature CT Detector for Six Acute Abdominal Emergencies

Ural Koç, Hasan Mete Erdoğan
Journal of Imaging Informatics in Medicine
Artificial Intelligence in Healthcare and Education
article

Evaluating Explicit Anatomical Priors Beyond a Mature CT Detector for Six Acute Abdominal Emergencies

Ural Koç, Hasan Mete Erdoğan
article en

Abstract

Abstract To test whether anatomical priors from a general-purpose organ segmentation model (TotalSegmentator, TS), applied at inference or during training, improve an externally validated YOLOv11 detector for six acute abdominal emergencies. The frozen detector was applied to 827 external Stanford Merlin CT studies with language-model report labels; a nested 280-study radiologist-adjudicated subset was the reference standard. TS-derived slice selection (Arm A), organ-state integration (Arm B), and their combination (Arm C) were compared with the detector alone under frozen, recalibrated, and fine-tuned conditions. The detector was also retrained from scratch (identical 10-epoch budget) with image channels only, with the patient’s TS organ maps as added input channels, or with another patient’s maps. AUROC was primary; comparisons used a paired study-level bootstrap. The detector generalized externally (macro AUROC 0.816 cohort; 0.879 adjudicated). Slice selection was non-inferior but not beneficial: nearly all confident detections already lay within the anchored organ’s axial range; organ-state fusion improved AUROC only for cholecystitis (hypothesis-generating). In single runs, training with organ maps raised internal test [email protected] (0.517 versus 0.482), and the model depended on the maps, but external macro AUROC did not improve (0.822 versus 0.829; $$\Delta $$ Δ −0.007, 95% CI −0.019 to +0.007) and kidney-stone AUROC fell (0.678 versus 0.768; exploratory), unlike with another patient’s maps. Per-site recalibration was the most effective operating-point adjustment (macro F1 +0.021); annotation-free fine-tuning reduced discrimination. Explicit anatomy, applied after detection or during training, did not improve this detector’s overall external discrimination. Per-site recalibration gave the largest operating-point gain.

Journal of Imaging Informatics in Medicine
Budapest University of Technology and Economics (HU), Ankara Bilkent City Hospital (TR)
Budapesti Műszaki és Gazdaságtudományi Egyetem
Good health and well-being
Openalex Percentile: Top 20%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.