Respiratory Viruses in the Air of Shared Indoor Environments: Multi-Country Molecular Surveillance Across Europe (TwinAIR)

Indoor environments are the dominant setting for human exposure to respiratory viruses, yet routine molecular surveillance of indoor air remains rare outside single-site studies. Within the Horizon Europe TwinAIR project, a single harmonised workflow was applied to 102 indoor air samples (2000 L each) collected between October 2024 and February 2026 at ten pilot settings in Germany, the United Kingdom, Ireland, Spain, Greece and Sweden, covering university teaching rooms, school classrooms and staff rooms, healthcare-associated offices, workplace offices, an elderly care facility and public transport vehicles. Air was collected onto gelatine membrane filters with a Sartorius MD8 Airport sampler, total nucleic acid was extracted with the QIAamp Viral RNA Mini kit, and five targets—SARS-CoV-2, human adenovirus, respiratory syncytial virus A/B, influenza A and rhinovirus—were quantified against target-specific standard curves as genome copies per cubic metre (GC/m3). At least one target was detected in 84 of 102 samples (82.4%; 95% CI 73.8–88.5). SARS-CoV-2 was the most frequent and most abundant target (64.7%; up to 8.36 × 106 GC/m3) and adenovirus was the second most frequent though consistently low in concentration (33.3%); both were recovered from all six countries. Rhinovirus (14.7%, five countries), RSV A/B (8.8%, four) and influenza A (6.9%, four) were detected less often yet reached high concentrations when present, showing that detection frequency alone substantially understates airborne viral burden. Detection of viral genome does not establish infectivity.

Authors

Institutions

Publication Details

Journal
Environments
Published
2026-10-16
DOI
https://doi.org/10.3390/environments13100561
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Respiratory Viruses in the Air of Shared Indoor Environments: Multi-Country Molecular Surveillance Across Europe (TwinAIR)

Anja Moldehn, Vangelis Angelakis, Mohammad Anwar H. Khan, Apostolos Vantarakis et al.
Environments
Indoor Air Quality and Microbial Exposure
article

Respiratory Viruses in the Air of Shared Indoor Environments: Multi-Country Molecular Surveillance Across Europe (TwinAIR)

Anja Moldehn, Vangelis Angelakis, Mohammad Anwar H. Khan, Apostolos Vantarakis, Angeliki Chatziantoniou, Christina Karamperi, Despoina Fytili, Gracia María Pedraza Cebrián, Theo Tryfonas, Zoi Kotsiri, Zoi Anastopoulou, Rafail Fokas, Xiaocui Chen, Eva Maria Munoz, Kalypso-Angeliki Koukouvini, Niusha Larylavasani
article en

Abstract

Indoor environments are the dominant setting for human exposure to respiratory viruses, yet routine molecular surveillance of indoor air remains rare outside single-site studies. Within the Horizon Europe TwinAIR project, a single harmonised workflow was applied to 102 indoor air samples (2000 L each) collected between October 2024 and February 2026 at ten pilot settings in Germany, the United Kingdom, Ireland, Spain, Greece and Sweden, covering university teaching rooms, school classrooms and staff rooms, healthcare-associated offices, workplace offices, an elderly care facility and public transport vehicles. Air was collected onto gelatine membrane filters with a Sartorius MD8 Airport sampler, total nucleic acid was extracted with the QIAamp Viral RNA Mini kit, and five targets—SARS-CoV-2, human adenovirus, respiratory syncytial virus A/B, influenza A and rhinovirus—were quantified against target-specific standard curves as genome copies per cubic metre (GC/m3). At least one target was detected in 84 of 102 samples (82.4%; 95% CI 73.8–88.5). SARS-CoV-2 was the most frequent and most abundant target (64.7%; up to 8.36 × 106 GC/m3) and adenovirus was the second most frequent though consistently low in concentration (33.3%); both were recovered from all six countries. Rhinovirus (14.7%, five countries), RSV A/B (8.8%, four) and influenza A (6.9%, four) were detected less often yet reached high concentrations when present, showing that detection frequency alone substantially understates airborne viral burden. Detection of viral genome does not establish infectivity.

EnvironmentsVol. 13(10)
Linköping University (SE), University of Patras (GR), University of Bristol (GB), Thriasio General Hospital of Elefsina (GR), e-Trikala (Greece) (GR), NILU (NO)
European Commission
Good health and well-being
Openalex Percentile: Top 18%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.