Repeated monitoring of low-level formaldehyde in air using an amperometric flow-cell biosensor with electrolyte circulation

A highly selective amperometric biosensor was developed for direct monitoring of low-level formaldehyde in air. The sensor consists of a flow-cell reaction unit with gas and liquid compartments separated by a porous PTFE diaphragm membrane. Formaldehyde dehydrogenase, NAD+, and ferrocenecarboxylic acid were used in the electrolyte solution, and the enzymatic reaction was monitored amperometrically at a carbon working electrode at a low applied potential of 80 mV versus Ag/AgCl. The electrolyte solution was circulated through the liquid compartment after each measurement to shorten the recovery time and maintain the activity of the enzyme-containing liquid phase. The sensor measured formaldehyde gas over the range of 1 ppb to 1.1 ppm within 5 min, covering concentrations relevant to indoor air monitoring. Formaldehyde concentrations down to 1 ppb were experimentally detected, and the sensor showed negligible responses to acetaldehyde, methanol, ethanol, benzene, and acetone at 100 ppb. The sensor also exhibited long-term operational stability, retaining approximately 80% of its initial response after 56 days when electrolyte circulation was used. Application to indoor air demonstrated that the proposed method could track transient changes in formaldehyde concentration associated with ventilation cycles. These results indicate that the present flow-cell biosensor provides a practical analytical method for repeated monitoring of low-level airborne formaldehyde with high sensitivity, high selectivity, and improved operational stability.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental & Analytical Chemistry
Published
2026-10-15
DOI
https://doi.org/10.1080/03067319.2026.2747041
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeated monitoring of low-level formaldehyde in air using an amperometric flow-cell biosensor with electrolyte circulation

下村猛, Touru Sumiya, Masatoshi Ono
International Journal of Environmental & Analytical Chemistry
Electrochemical sensors and biosensors
article

Repeated monitoring of low-level formaldehyde in air using an amperometric flow-cell biosensor with electrolyte circulation

下村猛, Touru Sumiya, Masatoshi Ono
article en

Abstract

A highly selective amperometric biosensor was developed for direct monitoring of low-level formaldehyde in air. The sensor consists of a flow-cell reaction unit with gas and liquid compartments separated by a porous PTFE diaphragm membrane. Formaldehyde dehydrogenase, NAD+, and ferrocenecarboxylic acid were used in the electrolyte solution, and the enzymatic reaction was monitored amperometrically at a carbon working electrode at a low applied potential of 80 mV versus Ag/AgCl. The electrolyte solution was circulated through the liquid compartment after each measurement to shorten the recovery time and maintain the activity of the enzyme-containing liquid phase. The sensor measured formaldehyde gas over the range of 1 ppb to 1.1 ppm within 5 min, covering concentrations relevant to indoor air monitoring. Formaldehyde concentrations down to 1 ppb were experimentally detected, and the sensor showed negligible responses to acetaldehyde, methanol, ethanol, benzene, and acetone at 100 ppb. The sensor also exhibited long-term operational stability, retaining approximately 80% of its initial response after 56 days when electrolyte circulation was used. Application to indoor air demonstrated that the proposed method could track transient changes in formaldehyde concentration associated with ventilation cycles. These results indicate that the present flow-cell biosensor provides a practical analytical method for repeated monitoring of low-level airborne formaldehyde with high sensitivity, high selectivity, and improved operational stability.

International Journal of Environmental & Analytical Chemistry
Funai Electric (Japan) (JP)
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.