Consumer Grade Wearable Sensor Metrics Are Associated with Internal Forces at Common Running Injury Locations

INTRODUCTION: Inexpensive consumer-grade wearable sensors have expanded possibilities to assess, monitor, or modify a runner's gait. However, it is unclear which sensor-measured gait metrics are strongly associated with internal loading at common injury locations. PURPOSE: To measure the association between gait metrics measured by consumer-grade wearable sensors and internal forces at the Achilles tendon and the patellofemoral joint. METHODS: 55 healthy runners wearing consumer-grade chest straps foot-pods completed a 38-minute run on an instrumented treadmill at 12 speeds from 70%-125% of self-reported typical running pace. A scaled musculoskeletal model derived from motion capture data and driven by static optimization was used to calculate Achilles tendon and patellofemoral joint forces during stance for each speed. Functional regression models were used to estimate the associations of each of nine sensor-measured gait metrics with internal forces across stance, after adjusting for body mass and running speed. RESULTS: At both the Achilles tendon and the patellofemoral joint, cadence, vertical oscillation, and vertical ratio (vertical oscillation divided by step length) showed the strongest associations with internal forces (maximum of 0.4-0.6 BW change in force per one standard deviation change in the gait metric). Other wearable sensor-measured gait metrics, including stance time, leg stiffness, and stance time percent showed weaker associations (<0.4 BW change in force per one standard deviation change in the gait metric). CONCLUSIONS: Runners with higher-than-average cadence, vertical oscillation, or vertical ratio values experience marked differences in internal forces at the Achilles tendon and patellofemoral joint. Of these gait metrics, cadence is the most practical for out-of-lab use because of its ease of accurate measurement with consumer-grade devices.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2026-10-16
DOI
https://doi.org/10.1249/mss.0000000000004191
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Consumer Grade Wearable Sensor Metrics Are Associated with Internal Forces at Common Running Injury Locations

Allison H. Gruber, John S. Raglin, Andrew William Brown, Jaroslaw Harezlak et al.
Medicine & Science in Sports & Exercise
Lower Extremity Biomechanics and Pathologies
article

Consumer Grade Wearable Sensor Metrics Are Associated with Internal Forces at Common Running Injury Locations

Allison H. Gruber, John S. Raglin, Andrew William Brown, Jaroslaw Harezlak, Stacey A. Meardon, John J. Davis IV
article en

Abstract

INTRODUCTION: Inexpensive consumer-grade wearable sensors have expanded possibilities to assess, monitor, or modify a runner's gait. However, it is unclear which sensor-measured gait metrics are strongly associated with internal loading at common injury locations. PURPOSE: To measure the association between gait metrics measured by consumer-grade wearable sensors and internal forces at the Achilles tendon and the patellofemoral joint. METHODS: 55 healthy runners wearing consumer-grade chest straps foot-pods completed a 38-minute run on an instrumented treadmill at 12 speeds from 70%-125% of self-reported typical running pace. A scaled musculoskeletal model derived from motion capture data and driven by static optimization was used to calculate Achilles tendon and patellofemoral joint forces during stance for each speed. Functional regression models were used to estimate the associations of each of nine sensor-measured gait metrics with internal forces across stance, after adjusting for body mass and running speed. RESULTS: At both the Achilles tendon and the patellofemoral joint, cadence, vertical oscillation, and vertical ratio (vertical oscillation divided by step length) showed the strongest associations with internal forces (maximum of 0.4-0.6 BW change in force per one standard deviation change in the gait metric). Other wearable sensor-measured gait metrics, including stance time, leg stiffness, and stance time percent showed weaker associations (<0.4 BW change in force per one standard deviation change in the gait metric). CONCLUSIONS: Runners with higher-than-average cadence, vertical oscillation, or vertical ratio values experience marked differences in internal forces at the Achilles tendon and patellofemoral joint. Of these gait metrics, cadence is the most practical for out-of-lab use because of its ease of accurate measurement with consumer-grade devices.

Medicine & Science in Sports & Exercise
East Carolina University (US), Bloomington Health Foundation (US), Indiana University Bloomington (US), Arkansas Children's Research Institute (US), University of Arkansas for Medical Sciences (US)
Good health and well-being
Openalex Percentile: Top 24%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.