Comparative Evaluation of Power-Law and Viscoelastic Hemolysis Models in the FDA Nozzle Benchmark Geometry
Abstract Purpose The mechanical damage of red blood cells (hemolysis) remains a key challenge in the design of blood-contacting medical devices. This study aims to compare the predictive performance of the empirical power-law model and the physiologically motivated viscoelastic model in the FDA nozzle benchmark geometry, with a focus on how model parameters and shear stress definitions influence hemolysis predictions. Methods Computational fluid dynamics (CFD) simulations were performed using a finite volume framework to resolve flow fields and shear stresses in the FDA nozzle. Both hemolysis models were implemented under identical geometry, mesh and boundary conditions. A parametric analysis was conducted by varying key model parameters, including the viscoelastic constants A , $$T_1$$ T 1 , $$T_2$$ T 2 , the shear stress threshold $$\tau _S$$ τ S , and the power-law parameters. Predictions were evaluated using both total shear stress and turbulent viscous shear stress (TVSS) formulations, and compared against experimental data. Conclusion The viscoelastic model demonstrated strong sensitivity to the relaxation time $$T_2$$ T 2 and to the choice of stress definition. A quasi-linear dependence on parameter A was identified, enabling calibration with experimental results. In contrast, the power-law model was less sensitive to stress definitions but strongly dependent on parameter fitting. The effect of $$\tau _S$$ τ S differed between the two models: it reduced hemolysis in the power-law case but increased it in the viscoelastic formulation. Background The viscoelastic model offers a more mechanistic description of hemolysis but requires careful parameter calibration and is highly sensitive to stress definitions. The power-law model remains computationally efficient and easier to implement, though empirical by nature. Future research should refine parameter estimation and extend validation to more complex flow regimes, considering feedback effects of hemolysis on viscosity. Ultimately, CFD prediction of hemolysis remains a challenging unsolved problem.
Authors
- Alberto Girelli (ORCID: https://orcid.org/0000-0003-3581-7726)
- Adélia Sequeira (ORCID: https://orcid.org/0000-0002-4216-6960)
- Tomáš Bodnár (ORCID: https://orcid.org/0000-0003-2991-8467)
- Giulia Giantesio (ORCID: https://orcid.org/0000-0002-7303-7408)
Institutions
- Università Cattolica del Sacro Cuore (IT)
- University of Lisbon (PT)
- University of Ferrara (IT)
- Czech Academy of Sciences (CZ)
- Simula Research Laboratory (NO)
- Czech Academy of Sciences, Institute of Mathematics (CZ)
- Instituto Superior Técnico (PT)
- Centro de Matemática Computacional e Estocástica (PT)
- Czech Technical University in Prague (CZ)
Publication Details
- Journal
- Cardiovascular Engineering and Technology
- Published
- 2026-10-16
- DOI
- https://doi.org/10.1007/s13239-026-00862-w
- Primary Topic
- Blood properties and coagulation
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Istituto Nazionale di Alta Matematica "Francesco Severi"
- Ministero dell’Istruzione, dell’Università e della Ricerca
- Akademie Věd České Republiky
- Università Cattolica del Sacro Cuore
- Gruppo Nazionale per la Fisica Matematica
- Fundação para a Ciência e a Tecnologia