Can machine learning be used to quantify blood loss based on hemodynamic data? Experimental study of controlled hemorrhagic shock in anesthetized piglets

Background Hemorrhagic compensatory physiological mechanisms may initially lead to an underestimation of the severity of a hemorrhage, for which quantification of blood lost volume is difficult. The objective of our study was to assess the suitability of machine learning (ML) to quantify blood depletion from critical care settings routinely available clinical and ultrasound data during the management of a hemorrhagic patient in a model of controlled hemorrhagic shock in anesthetized piglets. Methods We used data from anesthetized and ventilated piglets that underwent blood spoliation at 2 mL kg −1 min −1 until a mean arterial pressure (MAP) of 40 mmHg was achieved. The data recorded consisted of the hemodynamic and echocardiographic parameters routinely measured during the care of critically ill patients. We used these data to develop six machine learning models for blood loss quantification. Judgment criteria were the coefficient of determination R 2 , root mean squared error (RMSE) and mean absolute error (MAE), reported in mL between real depletion and that assessed by the ML models. Results A total of 84 piglets were included. For assessing blood depletion, R 2 was 0.62 ± 0.08, 0.61 ± 0.10, 0.60 ± 0.10, 0.60 ± 0.08, 0.58 ± 0.11, 0.57 ± 0.13, and 0.54 ± 0.10 for Support Vector Machine, XGBoost, Multicorrelation Models, Random Forest, K-Nearest Neighbors, Ensemble, and Multilayer Perceptron, respectively. The best-performing model (SVM) achieved an RMSE of 240 ± 27 mL and MAE of 186 ± 17 mL. Area under curve for detecting abundant blood loss (> 500 mL, equivalent to 15 mL kg −1 ) ranged from 0.856 to 0.895 across all classification models. Conclusion In this model of controlled hemorrhagic shock in piglets, ML seems to offer promising accuracy to quantify blood depletion using hemodynamic and echographic measures.

Authors

Institutions

Publication Details

Journal
Trauma
Published
2026-10-16
DOI
https://doi.org/10.1177/14604086261494768
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can machine learning be used to quantify blood loss based on hemodynamic data? Experimental study of controlled hemorrhagic shock in anesthetized piglets

Florian Ajavon, Laura Grau‐Mercier, Fabien Coisy, Xavier Bobbia et al.
Trauma
Hemodynamic Monitoring and Therapy
article

Can machine learning be used to quantify blood loss based on hemodynamic data? Experimental study of controlled hemorrhagic shock in anesthetized piglets

Florian Ajavon, Laura Grau‐Mercier, Fabien Coisy, Xavier Bobbia, Thibaut Markarian, Maxime Carriere, Céline Occelli, Dino Tikvesa, Thomas Sanchez
article en

Abstract

Background Hemorrhagic compensatory physiological mechanisms may initially lead to an underestimation of the severity of a hemorrhage, for which quantification of blood lost volume is difficult. The objective of our study was to assess the suitability of machine learning (ML) to quantify blood depletion from critical care settings routinely available clinical and ultrasound data during the management of a hemorrhagic patient in a model of controlled hemorrhagic shock in anesthetized piglets. Methods We used data from anesthetized and ventilated piglets that underwent blood spoliation at 2 mL kg −1 min −1 until a mean arterial pressure (MAP) of 40 mmHg was achieved. The data recorded consisted of the hemodynamic and echocardiographic parameters routinely measured during the care of critically ill patients. We used these data to develop six machine learning models for blood loss quantification. Judgment criteria were the coefficient of determination R 2 , root mean squared error (RMSE) and mean absolute error (MAE), reported in mL between real depletion and that assessed by the ML models. Results A total of 84 piglets were included. For assessing blood depletion, R 2 was 0.62 ± 0.08, 0.61 ± 0.10, 0.60 ± 0.10, 0.60 ± 0.08, 0.58 ± 0.11, 0.57 ± 0.13, and 0.54 ± 0.10 for Support Vector Machine, XGBoost, Multicorrelation Models, Random Forest, K-Nearest Neighbors, Ensemble, and Multilayer Perceptron, respectively. The best-performing model (SVM) achieved an RMSE of 240 ± 27 mL and MAE of 186 ± 17 mL. Area under curve for detecting abundant blood loss (> 500 mL, equivalent to 15 mL kg −1 ) ranged from 0.856 to 0.895 across all classification models. Conclusion In this model of controlled hemorrhagic shock in piglets, ML seems to offer promising accuracy to quantify blood depletion using hemodynamic and echographic measures.

Trauma
Inserm (FR), Université de Montpellier (FR), Aix-Marseille Université (FR), Centre Hospitalier Universitaire de Nice (FR), Assistance Publique Hôpitaux de Marseille (FR), Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR), Centre Hospitalier Universitaire de Montpellier (FR), Centre de Recherche en CardioVasculaire et Nutrition (FR), Université de Nîmes (FR)
Good health and well-being
Openalex Percentile: Top 10%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.