Functionality of platelets after in vitro testing of pulsatile total artificial hearts

Hemolysis is a metric of hemocompatibility in total artificial hearts (TAHs) but provides limited insight into platelet biology and thrombogenicity. We demonstrated reduced hemolysis with Realheart® TAH (RH) compared to FDA-approved SynCardia TAH (Sync). Here, we evaluated platelet function following exposure to both devices in a whole-blood in vitro system using a standardized ASTM F1830 protocol. Human blood (n = 5) was circulated for 360 min under controlled conditions (5 L/min, 100 mmHg, 37 °C) in RH, Sync, while matched static controls were maintained under identical temperature conditions. Platelets were assessed using metabolic (ATP, mitochondrial potential), phenotypic (surface markers, microparticles), and functional (agonist response, thromboelastometry) assays. Differences were observed between circulating and static conditions, including higher pH, increased lactate, and reduced platelet surface receptor expression, consistent with the non-physiological nature of static controls. Despite these changes, no evidence of increased platelet activation (CD62P), thrombogenicity (CD61+ microparticles), or mitochondrial damage (ATP, JC-1) was observed, and platelet function remained preserved by agonist stimulation and thromboelastometry. SynCardia increased mean platelet volume and reduced ATP levels, suggesting altered particle composition rather than intrinsic platelet dysfunction. These findings indicate preserved platelet integrity under clinically relevant TAH conditions and highlight that hemolysis and platelet responses represent distinct aspects of device hemocompatibility.

Authors

Institutions

Publication Details

Journal
Platelets
Published
2026-10-15
DOI
https://doi.org/10.1080/09537104.2026.2741743
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Functionality of platelets after in vitro testing of pulsatile total artificial hearts

Shaikh Faisal Zaman, Per Sandgren, Ina Laura Perkins
Platelets
Mechanical Circulatory Support Devices
article

Functionality of platelets after in vitro testing of pulsatile total artificial hearts

Shaikh Faisal Zaman, Per Sandgren, Ina Laura Perkins
article en

Abstract

Hemolysis is a metric of hemocompatibility in total artificial hearts (TAHs) but provides limited insight into platelet biology and thrombogenicity. We demonstrated reduced hemolysis with Realheart® TAH (RH) compared to FDA-approved SynCardia TAH (Sync). Here, we evaluated platelet function following exposure to both devices in a whole-blood in vitro system using a standardized ASTM F1830 protocol. Human blood (n = 5) was circulated for 360 min under controlled conditions (5 L/min, 100 mmHg, 37 °C) in RH, Sync, while matched static controls were maintained under identical temperature conditions. Platelets were assessed using metabolic (ATP, mitochondrial potential), phenotypic (surface markers, microparticles), and functional (agonist response, thromboelastometry) assays. Differences were observed between circulating and static conditions, including higher pH, increased lactate, and reduced platelet surface receptor expression, consistent with the non-physiological nature of static controls. Despite these changes, no evidence of increased platelet activation (CD62P), thrombogenicity (CD61+ microparticles), or mitochondrial damage (ATP, JC-1) was observed, and platelet function remained preserved by agonist stimulation and thromboelastometry. SynCardia increased mean platelet volume and reduced ATP levels, suggesting altered particle composition rather than intrinsic platelet dysfunction. These findings indicate preserved platelet integrity under clinically relevant TAH conditions and highlight that hemolysis and platelet responses represent distinct aspects of device hemocompatibility.

PlateletsVol. 37(1)
Karolinska Institutet (SE), Scandinavian Real Heart AB (Sweden) (SE)
Good health and well-being
Openalex Percentile: Top 24%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.