A deep feature-based approach for classifying flue gas pollutants and hazard identification using pyramid-dilated temporal convolution networks

Nowadays, real-world monitoring and accurate prediction for toxic gas concentration have gained much attention from researchers, as it provides great work in emergency validation situations and rescue works. The Artificial Intelligence (AI)-based gas concentration prediction techniques face more problems in terms of poor convergence speed, equal feature importance, and minimal accuracy. But, choosing the best design and also validating the most suitable safety measures are difficult due to the lack of execution of the important field examinations under emission regulations. So, a deep learning-based flue gas analysis model is implemented for hazard detection. Here, required samples are gathered from benchmark resources and features are extracted through Convolutional-Autoencoder with Spatial–Temporal Attention (CA-STA). The flue gas classification is performed using a Pyramid Dilated-based Adaptive Temporal Convolution Network (PD-ATCN), where the extracted features are given as inputs. The flexibility of the suggested approach is enhanced by fine-tuning the parameters of PD-ATCN using Improved Random Variable-based Cray Fish Optimization (IRV-CFO). Finally, the effectiveness of the proposed framework is evaluated through diverse performance metrics, which show higher robustness. In the accuracy analysis, the developed IRV-CFO-PD-ATCN gained superior typical flue gas pollutants classification and hazards identification outcome as 95.11% for dataset 1 and 92.6% for dataset 2, compared to baseline approaches. Hence, the experimental results showed that the suggested approach is capable of achieving more precise typical flue gas classification and hazards detection outcomes than others under dynamic conditions.

Authors

Publication Details

Journal
Scientific Reports
Published
2026-10-15
DOI
https://doi.org/10.1038/s41598-026-70943-2
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A deep feature-based approach for classifying flue gas pollutants and hazard identification using pyramid-dilated temporal convolution networks

K. Renganathan, B. Umamaheswari
Scientific Reports
Air Quality Monitoring and Forecasting
article

A deep feature-based approach for classifying flue gas pollutants and hazard identification using pyramid-dilated temporal convolution networks

K. Renganathan, B. Umamaheswari
article en

Abstract

Nowadays, real-world monitoring and accurate prediction for toxic gas concentration have gained much attention from researchers, as it provides great work in emergency validation situations and rescue works. The Artificial Intelligence (AI)-based gas concentration prediction techniques face more problems in terms of poor convergence speed, equal feature importance, and minimal accuracy. But, choosing the best design and also validating the most suitable safety measures are difficult due to the lack of execution of the important field examinations under emission regulations. So, a deep learning-based flue gas analysis model is implemented for hazard detection. Here, required samples are gathered from benchmark resources and features are extracted through Convolutional-Autoencoder with Spatial–Temporal Attention (CA-STA). The flue gas classification is performed using a Pyramid Dilated-based Adaptive Temporal Convolution Network (PD-ATCN), where the extracted features are given as inputs. The flexibility of the suggested approach is enhanced by fine-tuning the parameters of PD-ATCN using Improved Random Variable-based Cray Fish Optimization (IRV-CFO). Finally, the effectiveness of the proposed framework is evaluated through diverse performance metrics, which show higher robustness. In the accuracy analysis, the developed IRV-CFO-PD-ATCN gained superior typical flue gas pollutants classification and hazards identification outcome as 95.11% for dataset 1 and 92.6% for dataset 2, compared to baseline approaches. Hence, the experimental results showed that the suggested approach is capable of achieving more precise typical flue gas classification and hazards detection outcomes than others under dynamic conditions.

Scientific Reports
Openalex Percentile: Top 21%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.