Microbubble Timing and Vascular Geometry Are Associated With Vessel‐Level Blood–Brain Barrier Opening During Focused Ultrasound

Objectives To examine whether minute‐scale microbubble handling and injection‐to‐sonication timing are associated with vessel‐level focused ultrasound (FUS)–mediated blood–brain barrier opening (BBBO), and whether control normalization improves longitudinal 2‐photon (2P) measurements. Methods Cranial‐windowed mice received FITC–dextran (40 kDa) and SonoVue microbubbles by retro‐orbital injection, followed by 1.0 MHz FUS at 0.2–0.4 MPa. Two‐photon stacks were acquired over 0–15 minutes. Frangi vesselness and Otsu thresholding defined vessel masks and a perivascular ring for extravasation analysis. Three timing conditions were compared: standard (injection within ~5 seconds of reconstitution, sonication immediately); Microbubble Floating (microbubbles held 2 minutes before injection); and Sonication Delay (sonication started 2 minutes after injection). Per‐mouse AUC used 2‐way ANOVA; slice‐level vessel‐area dependence used a linear mixed‐effects model with mouse as a random intercept. Results Control intravascular fluorescence decreased by ~24% over 15 minutes, showing that the intravascular signal is not a stable denominator; control‐normalized extravascular AUC was therefore the primary metric. Under the standard protocol, extravascular AUC peaked at 0.3 MPa, but the across‐pressure difference was not significant ( F (2,6) = 3.36, p = .105). Timing effects were descriptive: relative to standard, both Microbubble Floating and Sonication Delay increased extravascular AUC at 0.2 MPa but decreased it at 0.3 MPa. Vessel area was inversely associated with extravasation at the slice level ( β = −0.37 per μm 2 , p = .010), with mouse‐level intraclass correlation (ICC = 0.80) indicating dominant between‐mouse variability. Conclusions Microbubble handling and injection‐to‐sonication timing are potential protocol variables in FUS‐BBBO studies. Control‐normalized extravascular metrics provide a reproducible framework for vessel‐level longitudinal 2‐photon quantification.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound in Medicine
Published
2026-10-14
DOI
https://doi.org/10.1002/jum.70511
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microbubble Timing and Vascular Geometry Are Associated With Vessel‐Level Blood–Brain Barrier Opening During Focused Ultrasound

Ki Soo Kim, Seunghwan Choi, Sun Kwang Kim, Juyoung Park et al.
Journal of Ultrasound in Medicine
Ultrasound and Hyperthermia Applications
article

Microbubble Timing and Vascular Geometry Are Associated With Vessel‐Level Blood–Brain Barrier Opening During Focused Ultrasound

Ki Soo Kim, Seunghwan Choi, Sun Kwang Kim, Juyoung Park, Hyemin Lee, Seongdong Park
article en

Abstract

Objectives To examine whether minute‐scale microbubble handling and injection‐to‐sonication timing are associated with vessel‐level focused ultrasound (FUS)–mediated blood–brain barrier opening (BBBO), and whether control normalization improves longitudinal 2‐photon (2P) measurements. Methods Cranial‐windowed mice received FITC–dextran (40 kDa) and SonoVue microbubbles by retro‐orbital injection, followed by 1.0 MHz FUS at 0.2–0.4 MPa. Two‐photon stacks were acquired over 0–15 minutes. Frangi vesselness and Otsu thresholding defined vessel masks and a perivascular ring for extravasation analysis. Three timing conditions were compared: standard (injection within ~5 seconds of reconstitution, sonication immediately); Microbubble Floating (microbubbles held 2 minutes before injection); and Sonication Delay (sonication started 2 minutes after injection). Per‐mouse AUC used 2‐way ANOVA; slice‐level vessel‐area dependence used a linear mixed‐effects model with mouse as a random intercept. Results Control intravascular fluorescence decreased by ~24% over 15 minutes, showing that the intravascular signal is not a stable denominator; control‐normalized extravascular AUC was therefore the primary metric. Under the standard protocol, extravascular AUC peaked at 0.3 MPa, but the across‐pressure difference was not significant ( F (2,6) = 3.36, p = .105). Timing effects were descriptive: relative to standard, both Microbubble Floating and Sonication Delay increased extravascular AUC at 0.2 MPa but decreased it at 0.3 MPa. Vessel area was inversely associated with extravasation at the slice level ( β = −0.37 per μm 2 , p = .010), with mouse‐level intraclass correlation (ICC = 0.80) indicating dominant between‐mouse variability. Conclusions Microbubble handling and injection‐to‐sonication timing are potential protocol variables in FUS‐BBBO studies. Control‐normalized extravascular metrics provide a reproducible framework for vessel‐level longitudinal 2‐photon quantification.

Journal of Ultrasound in Medicine
Gachon University (KR), Cheongju University (KR), Kyung Hee University (KR)
Openalex Percentile: Top 24%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.