Analytical and experimental analysis of timber–concrete composite beams: Influence of connection system and fiberglass reinforcement

The use of timber–concrete composite structures offer several advantages, particularly from an environmental standpoint, as they result in lower environmental impacts compared to others structural solutions. In addition, timber–concrete composite beams can be strengthened with fiber reinforced polymers (FRP), thereby increasing their flexural strength. In this context, the present study provides an experimental investigation of factors influencing the behavior of timber–concrete composite beams, specifically the connection system and the use of FRP. Furthermore, the experimental results were compared with predictions obtained from an analytical model available in the literature. Two connection systems were considered: one consisting of inclined steel bars and another consisting of inclined steel bars associated with triangular notches. Glass fibers were used as the FRP reinforcement. The composite beams were subjected to three-point bending tests in order to evaluate load–deflection behavior at mid-span, load–slip response between timber and concrete, strain distribution across the cross section, and failure modes. The results indicated that both the connection system and the use of FRP influenced the failure mode, ductility, and interfacial slip between the constituent materials. A 2.5% reduction in the ultimate load was observed for the beams with notched connections compared with those connected exclusively by steel bars, whereas, for the beams with inclined steel bars, the use of FRP increased the maximum load capacity by 22.6%. In beams with notched connections, the concrete exhibited only compressive strains, while the timber exhibited both tensile and compressive strains. For the beams with RB connections, both the timber and concrete components exhibited tensile and compressive strains in the unreinforced specimens, whereas in the GFRP-reinforced specimens, the concrete exhibited compressive strains, while the timber component exhibited both tensile and compressive strains. For the beams investigated, the experimentally determined service stiffness was 3–17% higher than that predicted by the analytical model.

Authors

Institutions

Publication Details

Journal
Structures
Published
2026-10-15
DOI
https://doi.org/10.1016/j.istruc.2026.113327
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical and experimental analysis of timber–concrete composite beams: Influence of connection system and fiberglass reinforcement

Felipi Pablo Damasceno Fernandes, Júlio César Molina, Jorge Munaiar Neto
Structures
Structural Load-Bearing Analysis
article

Analytical and experimental analysis of timber–concrete composite beams: Influence of connection system and fiberglass reinforcement

Felipi Pablo Damasceno Fernandes, Júlio César Molina, Jorge Munaiar Neto
article en

Abstract

The use of timber–concrete composite structures offer several advantages, particularly from an environmental standpoint, as they result in lower environmental impacts compared to others structural solutions. In addition, timber–concrete composite beams can be strengthened with fiber reinforced polymers (FRP), thereby increasing their flexural strength. In this context, the present study provides an experimental investigation of factors influencing the behavior of timber–concrete composite beams, specifically the connection system and the use of FRP. Furthermore, the experimental results were compared with predictions obtained from an analytical model available in the literature. Two connection systems were considered: one consisting of inclined steel bars and another consisting of inclined steel bars associated with triangular notches. Glass fibers were used as the FRP reinforcement. The composite beams were subjected to three-point bending tests in order to evaluate load–deflection behavior at mid-span, load–slip response between timber and concrete, strain distribution across the cross section, and failure modes. The results indicated that both the connection system and the use of FRP influenced the failure mode, ductility, and interfacial slip between the constituent materials. A 2.5% reduction in the ultimate load was observed for the beams with notched connections compared with those connected exclusively by steel bars, whereas, for the beams with inclined steel bars, the use of FRP increased the maximum load capacity by 22.6%. In beams with notched connections, the concrete exhibited only compressive strains, while the timber exhibited both tensile and compressive strains. For the beams with RB connections, both the timber and concrete components exhibited tensile and compressive strains in the unreinforced specimens, whereas in the GFRP-reinforced specimens, the concrete exhibited compressive strains, while the timber component exhibited both tensile and compressive strains. For the beams investigated, the experimentally determined service stiffness was 3–17% higher than that predicted by the analytical model.

StructuresVol. 94
Institute of Physics (PL), Universidade Federal Rural de Pernambuco (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Industry, innovation and infrastructure
Openalex Percentile: Top 19%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.