Agreement of 11-Sensor Plantar-Pressure Configurations with a Full Pedar-X Array for Estimating Center of Pressure and Pressure-Derived Vertical Force in Individuals with Flatfoot During Walking and Running
Dense in-shoe pressure arrays (e.g., 99 sensors) are costly and cumbersome, limiting gait monitoring during dynamic activities. This study evaluated the agreement between the center of pressure (CoP) and pressure-derived vertical ground reaction force (vGRF) estimated from minimal 11-sensor configurations and a full Pedar-X array in individuals with flatfoot during walking and running. Twelve adults with flatfoot performed walking (5 and 7 km/h) and running (11 and 13 km/h) trials with simultaneous Pedar-X recording. Four 11-sensor configurations were compared against the 99-sensor full-array reference using Pearson correlation, root mean square error (RMSE), two-way random-effects intraclass correlation coefficients ICC(A,1), and Bland–Altman analysis. All configurations correlated significantly with the full-array reference for CoP (r = 0.859–0.971) and vGRF (r = 0.867–0.990). CoP RMSE ranged from 5.23 to 8.13 mm (medial–lateral) and 14.00 to 28.20 mm (anterior–posterior), with ICCs of 0.66–0.74 and 0.84–0.92, respectively. Raw vGRF showed moderate agreement (ICC = 0.46–0.56) with systematic underestimation, whereas per-user proportional calibration improved agreement to ICC = 0.90–0.98. Carefully placed minimal sensor configurations can track CoP and the vGRF waveform in individuals with flatfoot with high agreement relative to a full-array reference, supporting low-cost wearable gait monitoring with brief user calibration.
Authors
- Ping‐Hung Lee
- Yi‐Jia Lin
- MinYan He (ORCID: https://orcid.org/0000-0003-0952-4786)
- Tzyy-Yuang Shiang
Publication Details
- Journal
- Sensors
- Published
- 2026-11-19
- DOI
- https://doi.org/10.3390/s26227318
- Primary Topic
- Lower Extremity Biomechanics and Pathologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00