Radial Tiny Golden Angle UTE (tyGA‐UTE) for Cardiac MRI in the Small Animal Model

Robust cardiorespiratory motion correction is critical for high-quality ultra-high-field (UHF) preclinical cardiac magnetic resonance imaging (MRI). Whereas radial tiny golden angle (tyGA) sampling, data-driven self-gating (sg), compressed sensing (CS), and ultrashort echo time (UTE) are individually well-established techniques, their integration into a unified acquisition and reconstruction pipeline, together with systematic validation at 11.7 T remains insufficiently explored. This study presents and validates a UHF-optimized tyGA-based UTE workflow that enables high-temporal-resolution sliding-window dynamic imaging (SW-tyGA-UTE) and high-spatial-resolution cardiorespiratory self-gated cine imaging (Gated-tyGA-UTE) from a single continuous acquired tyGA acquisition. All experiments were performed on an 11.7-T small-animal MRI system in 16 healthy wild-type mice. Cardiac functional parameters, image quality metrics (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]), and inter-/intra-observer reproducibility were systematically compared between the proposed tyGA-UTE pipeline and two navigator-gated reference techniques: retrospectively gated FLASH and UTE methodologies. SW-tyGA-UTE and Gated-tyGA-UTE reconstructions yielded global left ventricular functional parameters comparable to those obtained with the reference methods (all p > 0.05). All functional metrics showed excellent intra-observer (ICC = 0.94-0.99) and inter-observer (ICC = 0.90-0.98) reproducibility, with ejection fraction showing the highest measurement consistency. Image quality was evaluated using an image-based within-ROI noise quantification approach that captures both thermal noise and reconstruction-related artifacts. In this analysis, the Gated-tyGA-UTE protocol showed no statistically significant differences in left ventricular blood-pool SNR, myocardial SNR, or CNR relative to the reference sequences. In contrast, the high-temporal-resolution sliding-window reconstruction showed significantly reduced image quality across all three metrics, consistent with the expected spatiotemporal trade-off of undersampled dynamic imaging. This study validates a robust, UHF-optimized tyGA-UTE imaging workflow that generates both high-fidelity quantitative cine data and ultra-fast dynamic cardiac images from a single acquisition. The unified pipeline eliminates the need for sequential repeated scans, minimizes anesthesia-related physiological variability, and improves experimental efficiency, providing a practical tool for preclinical cardiac phenotyping, longitudinal studies, and drug screening.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-10-14
DOI
https://doi.org/10.1002/nbm.70418
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radial Tiny Golden Angle UTE (tyGA‐UTE) for Cardiac MRI in the Small Animal Model

Patrick S. Metze, Pengxi Han, Benzheng Wei, Volker Rasche et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Radial Tiny Golden Angle UTE (tyGA‐UTE) for Cardiac MRI in the Small Animal Model

Patrick S. Metze, Pengxi Han, Benzheng Wei, Volker Rasche, Hao Li
article en

Abstract

Robust cardiorespiratory motion correction is critical for high-quality ultra-high-field (UHF) preclinical cardiac magnetic resonance imaging (MRI). Whereas radial tiny golden angle (tyGA) sampling, data-driven self-gating (sg), compressed sensing (CS), and ultrashort echo time (UTE) are individually well-established techniques, their integration into a unified acquisition and reconstruction pipeline, together with systematic validation at 11.7 T remains insufficiently explored. This study presents and validates a UHF-optimized tyGA-based UTE workflow that enables high-temporal-resolution sliding-window dynamic imaging (SW-tyGA-UTE) and high-spatial-resolution cardiorespiratory self-gated cine imaging (Gated-tyGA-UTE) from a single continuous acquired tyGA acquisition. All experiments were performed on an 11.7-T small-animal MRI system in 16 healthy wild-type mice. Cardiac functional parameters, image quality metrics (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]), and inter-/intra-observer reproducibility were systematically compared between the proposed tyGA-UTE pipeline and two navigator-gated reference techniques: retrospectively gated FLASH and UTE methodologies. SW-tyGA-UTE and Gated-tyGA-UTE reconstructions yielded global left ventricular functional parameters comparable to those obtained with the reference methods (all p > 0.05). All functional metrics showed excellent intra-observer (ICC = 0.94-0.99) and inter-observer (ICC = 0.90-0.98) reproducibility, with ejection fraction showing the highest measurement consistency. Image quality was evaluated using an image-based within-ROI noise quantification approach that captures both thermal noise and reconstruction-related artifacts. In this analysis, the Gated-tyGA-UTE protocol showed no statistically significant differences in left ventricular blood-pool SNR, myocardial SNR, or CNR relative to the reference sequences. In contrast, the high-temporal-resolution sliding-window reconstruction showed significantly reduced image quality across all three metrics, consistent with the expected spatiotemporal trade-off of undersampled dynamic imaging. This study validates a robust, UHF-optimized tyGA-UTE imaging workflow that generates both high-fidelity quantitative cine data and ultra-fast dynamic cardiac images from a single acquisition. The unified pipeline eliminates the need for sequential repeated scans, minimizes anesthesia-related physiological variability, and improves experimental efficiency, providing a practical tool for preclinical cardiac phenotyping, longitudinal studies, and drug screening.

NMR in BiomedicineVol. 39(11)
Shandong University of Traditional Chinese Medicine (CN), Universität Ulm (DE), Shandong Provincial QianFoShan Hospital (CN), University Hospital Ulm (DE), Shandong First Medical University (CN), Technische Hochschule Ulm (DE)
Openalex Percentile: Top 13%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.