MicroRNAs as Diagnostic Biomarkers for Deep Vein Thrombosis

Background/Objectives: In patients with suspected acute deep vein thrombosis (DVT), new blood biomarkers with high specificity for DVT could potentially lower the proportion of patients requiring imaging. The plasma microRNAs (miRs) miR-134-5p, miR-103a-3p and miR-210-3p have been proposed as diagnostic biomarkers of venous thromboembolism, but their diagnostic accuracy for acute DVT has not been investigated. We aimed to assess the diagnostic performance of miR-134-5p, miR-103a-3p and miR-210-3p for DVT in patients with suspected first-lifetime acute lower-extremity DVT. Methods: This prospective cross-sectional study consecutively included outpatients with suspected first-lifetime acute lower-extremity DVT. Plasma levels of miRs were measured using reverse transcription quantitative polymerase chain reaction. DVT status was determined by whole-leg duplex compression ultrasonography. Diagnostic test performance was assessed by the area under the curves (AUCs) from receiver operating characteristic curves with corresponding 95% confidence intervals (95% CI). The diagnostic accuracy of D-dimer was also assessed for comparison. Results: Among the 360 patients included in this study, 28% had a first-lifetime acute lower-extremity DVT. The AUCs for miR-134-5p, miR-103a-3p, and miR-210-3p ranged from 0.53 to 0.57, with 95% CIs overlapping 0.50. D-dimer had a sensitivity of 97% and specificity of 41% using the cut-off value of 0.5 µg/mL. Conclusion: Plasma miR-134-5p, miR-103a-3p and miR-210-3p showed poor diagnostic test performance for DVT. Our findings suggest that these miRs would not be helpful in discriminating between patients in whom DVT can be safely excluded and those who require imaging.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-10-15
DOI
https://doi.org/10.3390/diagnostics16203351
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MicroRNAs as Diagnostic Biomarkers for Deep Vein Thrombosis

Thor Ueland, Ellen Elisabeth Brodin, John‐Bjarne Hansen, Sigrid Kufaas Brækkan et al.
Diagnostics
Venous Thromboembolism Diagnosis and Management
article

MicroRNAs as Diagnostic Biomarkers for Deep Vein Thrombosis

Thor Ueland, Ellen Elisabeth Brodin, John‐Bjarne Hansen, Sigrid Kufaas Brækkan, Vårin Eiriksdatter Wikan, Gholamreza Jafari Yeganeh, Øyvind Øverli
article en

Abstract

Background/Objectives: In patients with suspected acute deep vein thrombosis (DVT), new blood biomarkers with high specificity for DVT could potentially lower the proportion of patients requiring imaging. The plasma microRNAs (miRs) miR-134-5p, miR-103a-3p and miR-210-3p have been proposed as diagnostic biomarkers of venous thromboembolism, but their diagnostic accuracy for acute DVT has not been investigated. We aimed to assess the diagnostic performance of miR-134-5p, miR-103a-3p and miR-210-3p for DVT in patients with suspected first-lifetime acute lower-extremity DVT. Methods: This prospective cross-sectional study consecutively included outpatients with suspected first-lifetime acute lower-extremity DVT. Plasma levels of miRs were measured using reverse transcription quantitative polymerase chain reaction. DVT status was determined by whole-leg duplex compression ultrasonography. Diagnostic test performance was assessed by the area under the curves (AUCs) from receiver operating characteristic curves with corresponding 95% confidence intervals (95% CI). The diagnostic accuracy of D-dimer was also assessed for comparison. Results: Among the 360 patients included in this study, 28% had a first-lifetime acute lower-extremity DVT. The AUCs for miR-134-5p, miR-103a-3p, and miR-210-3p ranged from 0.53 to 0.57, with 95% CIs overlapping 0.50. D-dimer had a sensitivity of 97% and specificity of 41% using the cut-off value of 0.5 µg/mL. Conclusion: Plasma miR-134-5p, miR-103a-3p and miR-210-3p showed poor diagnostic test performance for DVT. Our findings suggest that these miRs would not be helpful in discriminating between patients in whom DVT can be safely excluded and those who require imaging.

DiagnosticsVol. 16(20)
Oslo University Hospital (NO), University of Oslo (NO), Akershus University Hospital (NO), Thrombosis Research Institute (GB), UiT The Arctic University of Norway (NO)
Stiftelsen Kristian Gerhard Jebsen
Good health and well-being
Openalex Percentile: Top 10%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.