Medical imaging of superparamagnetic iron oxide nanoparticle-labeled stem cells: a review on tracking strategies for regenerative medicine

Abstract Stem cell-based therapies have substantial potential in regenerative medicine, but their translation depends in part on reliable, non-invasive assessment of transplanted-cell localization and fate. Superparamagnetic iron oxide nanoparticles (SPIONs) have been widely used to label stem and stromal cells for imaging. This structured narrative review, informed by a systematic PubMed literature search, examines the imaging strategies used for SPION-labeled stem-cell tracking and the signal mechanisms underlying multimodal approaches. The modality-specific searches retrieved 218 records; removal of 16 duplicate records left 202 unique publications for relevance assessment. Evidence was synthesized at the study level rather than using search yields as denominators. MRI was the principal modality for direct visualization of SPIO-labeled cells, although susceptibility-related blooming, label dilution, extracellular iron, and uptake by host phagocytes complicate quantitative interpretation and assessment of cell viability. CT and micro-CT had limited roles in direct cell tracking and were used mainly for complementary anatomical or structural assessment. Conventional and focused ultrasound were used predominantly for guidance, delivery, or assistance with labeling, whereas MSOT can provide optical cell-tracking contrast when an appropriate optically absorbing construct is used. PET and SPECT detect radionuclide emissions or reporter-derived signals rather than magnetic SPIO signal; when a radionuclide is physically linked to an SPIO construct, the nuclear signal may report that radiolabeled construct but remains emission-based. Magnetic particle imaging (MPI) directly detects SPIO and offers tracer-specific quantitative potential, although clinical availability remains limited. Future translation requires rigorous signal attribution, standardized nanoparticle and labeling characterization, validation of cell-function preservation, improved longitudinal quantification, and harmonized regulatory and manufacturing frameworks.

Authors

Institutions

Publication Details

Journal
Stem Cell Research & Therapy
Published
2026-10-14
DOI
https://doi.org/10.1186/s13287-026-05346-1
Primary Topic
Mesenchymal stem cell research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Medical imaging of superparamagnetic iron oxide nanoparticle-labeled stem cells: a review on tracking strategies for regenerative medicine

Armaghan Moghaddam, Davood Mehrabani, Fariba Zarei, Hossein Ali Khonakdar et al.
Stem Cell Research & Therapy
Mesenchymal stem cell research
article

Medical imaging of superparamagnetic iron oxide nanoparticle-labeled stem cells: a review on tracking strategies for regenerative medicine

Armaghan Moghaddam, Davood Mehrabani, Fariba Zarei, Hossein Ali Khonakdar, Mahdi Saeedi-Moghadam, Reza Jalli, Banafsheh Zeinali-Rafsanjani
article en

Abstract

Abstract Stem cell-based therapies have substantial potential in regenerative medicine, but their translation depends in part on reliable, non-invasive assessment of transplanted-cell localization and fate. Superparamagnetic iron oxide nanoparticles (SPIONs) have been widely used to label stem and stromal cells for imaging. This structured narrative review, informed by a systematic PubMed literature search, examines the imaging strategies used for SPION-labeled stem-cell tracking and the signal mechanisms underlying multimodal approaches. The modality-specific searches retrieved 218 records; removal of 16 duplicate records left 202 unique publications for relevance assessment. Evidence was synthesized at the study level rather than using search yields as denominators. MRI was the principal modality for direct visualization of SPIO-labeled cells, although susceptibility-related blooming, label dilution, extracellular iron, and uptake by host phagocytes complicate quantitative interpretation and assessment of cell viability. CT and micro-CT had limited roles in direct cell tracking and were used mainly for complementary anatomical or structural assessment. Conventional and focused ultrasound were used predominantly for guidance, delivery, or assistance with labeling, whereas MSOT can provide optical cell-tracking contrast when an appropriate optically absorbing construct is used. PET and SPECT detect radionuclide emissions or reporter-derived signals rather than magnetic SPIO signal; when a radionuclide is physically linked to an SPIO construct, the nuclear signal may report that radiolabeled construct but remains emission-based. Magnetic particle imaging (MPI) directly detects SPIO and offers tracer-specific quantitative potential, although clinical availability remains limited. Future translation requires rigorous signal attribution, standardized nanoparticle and labeling characterization, validation of cell-function preservation, improved longitudinal quantification, and harmonized regulatory and manufacturing frameworks.

Stem Cell Research & Therapy
Shiraz University (IR), Shiraz University of Medical Sciences (IR), Iran Polymer and Petrochemical Institute (IR)
Openalex Percentile: Top 13%
Mesenchymal stem cell research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.