The Biomechanical Mechanism of Cranial Implant Exposure Following Decreased Intracranial Pressure: A Finite Element Analysis Study

Background: Skull prosthesis is widely used for cranioplasty, yet long-term implant exposure remains a challenging complication frequently requiring reoperation. Clinical observations suggest an association between low intracranial pressure (ICP) and progressive scalp thinning, with possible progression to mesh erosion and implant exposure. However, the potential biomechanical mechanism by which dynamic ICP fluctuations may contribute to scalp atrophy and implant exposure has not been characterized owing to limitations of in vivo measurement. Methods: To investigate the potential biomechanical basis of low ICP-induced exposure, finite element analysis was used to simulate the mechanical responses of three cranial implant designs (combine-pattern titanium mesh, circular-pore titanium mesh, polyetheretherketoneplate) and overlying scalp under dynamic ICP. A skull model was generated from Computed Tomography data. Loading included a uniform 50 N force with continuously graded ICP (−15 to 30 mmHg) and localized 50 N forces at central and off-central regions under discrete ICP levels. Results: This study provides the biomechanical insights that low ICP may amplify stress on scalp overlying combined-pattern titanium mesh, supporting the “low ICP–scalp atrophy–exposure” cascade. The circular-pore titanium mesh consistently exhibited low and stable mechanical responses across all pressures, whereas polyetheretherketone plate demonstrated nonlinear behavior with aberrantly high-stress under specific boundary conditions. The central implant region was identified as a potentially vulnerable zone. Conclusions: Low ICP significantly elevates central scalp stress, suggesting it may be a mechanical contributor to implant exposure. Circular-pore titanium mesh and polyetheretherketone plate showed more favorable biomechanical behavior, warranting further validation. In high-risk scenarios, central porosity reduction or flexible transitions may be considered potential design modifications to mitigate exposure.

Authors

Institutions

Publication Details

Journal
Biomedicines
Published
2026-10-15
DOI
https://doi.org/10.3390/biomedicines14102348
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Biomechanical Mechanism of Cranial Implant Exposure Following Decreased Intracranial Pressure: A Finite Element Analysis Study

Lijian Lang, Ruizhe Zheng, 张林峰, Zengxin Qi et al.
Biomedicines
Traumatic Brain Injury and Neurovascular Disturbances
article

The Biomechanical Mechanism of Cranial Implant Exposure Following Decreased Intracranial Pressure: A Finite Element Analysis Study

Lijian Lang, Ruizhe Zheng, 张林峰, Zengxin Qi, Wenqian Shi, Jiayu Chen, Xuehai Wu, Wentao Huang, Dongchang Shao, Jiuqi Yan
article en

Abstract

Background: Skull prosthesis is widely used for cranioplasty, yet long-term implant exposure remains a challenging complication frequently requiring reoperation. Clinical observations suggest an association between low intracranial pressure (ICP) and progressive scalp thinning, with possible progression to mesh erosion and implant exposure. However, the potential biomechanical mechanism by which dynamic ICP fluctuations may contribute to scalp atrophy and implant exposure has not been characterized owing to limitations of in vivo measurement. Methods: To investigate the potential biomechanical basis of low ICP-induced exposure, finite element analysis was used to simulate the mechanical responses of three cranial implant designs (combine-pattern titanium mesh, circular-pore titanium mesh, polyetheretherketoneplate) and overlying scalp under dynamic ICP. A skull model was generated from Computed Tomography data. Loading included a uniform 50 N force with continuously graded ICP (−15 to 30 mmHg) and localized 50 N forces at central and off-central regions under discrete ICP levels. Results: This study provides the biomechanical insights that low ICP may amplify stress on scalp overlying combined-pattern titanium mesh, supporting the “low ICP–scalp atrophy–exposure” cascade. The circular-pore titanium mesh consistently exhibited low and stable mechanical responses across all pressures, whereas polyetheretherketone plate demonstrated nonlinear behavior with aberrantly high-stress under specific boundary conditions. The central implant region was identified as a potentially vulnerable zone. Conclusions: Low ICP significantly elevates central scalp stress, suggesting it may be a mechanical contributor to implant exposure. Circular-pore titanium mesh and polyetheretherketone plate showed more favorable biomechanical behavior, warranting further validation. In high-risk scenarios, central porosity reduction or flexible transitions may be considered potential design modifications to mitigate exposure.

BiomedicinesVol. 14(10)
Shanghai Medical College of Fudan University (CN), Fudan University (CN), Xinjiang Production and Construction Corps (CN), Ministry of Science and Technology (VN), Huashan Hospital (CN)
Good health and well-being
Openalex Percentile: Top 14%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.