Microfluidic Focusing of Heterogeneous Bacterial Immunocomplexes for Reproducible SERS Immunoassays

Magnetic bead-based surface-enhanced Raman scattering (SERS) immunoassays enable sensitive and multiplexed bacterial detection. However, bacterial targets form heterogeneous magnetic bead-bacterium-SERS nanotag immunocomplexes that vary in size, morphology, and nanotag loading. In static capillary-based measurements, different numbers of heterogeneous immunocomplexes are therefore located within the laser focal volume at each measurement position, resulting in large signal fluctuations and poor measurement reproducibility. In this study, we developed an elasto-inertial microfluidic platform that enables three-dimensional focusing of bacterial immunocomplexes for reproducible quantitative SERS measurements. Bacterial immunocomplexes suspended in 0.5% (w/v) poly(ethylene oxide) were focused near the center of a straight microchannel and continuously passed through a fixed Raman measurement region. High-speed imaging and cross-sectional Raman mapping confirmed central focusing of the immunocomplexes in both the lateral and vertical directions. Compared with static capillary-based measurements, the coefficient of variation decreased from 41.17% to 7.85% for Staphylococcus aureus and from 64.62% to 6.42% for Pseudomonas aeruginosa. The corresponding R2 values increased from 0.857 to 0.985 and from 0.680 to 0.971, respectively. The corresponding limits of detection were 2.32 × 104 CFU/mL for Staphylococcus aureus and 8.50 × 104 CFU/mL for Pseudomonas aeruginosa. The same focusing strategy was further applied to simultaneous detection of the two bacterial targets using spectrally distinguishable Raman reporters. These results demonstrate that three-dimensional elasto-inertial focusing provides an effective approach for improving the reproducibility of quantitative single- and multiplex bacterial SERS immunoassays.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-10-15
DOI
https://doi.org/10.1021/acssensors.6c03516
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic Focusing of Heterogeneous Bacterial Immunocomplexes for Reproducible SERS Immunoassays

Jaebum Choo, Thanh Mien Nguyen, Beomseok Cha, Kihyun Kim et al.
ACS Sensors
Microfluidic and Bio-sensing Technologies
article

Microfluidic Focusing of Heterogeneous Bacterial Immunocomplexes for Reproducible SERS Immunoassays

Jaebum Choo, Thanh Mien Nguyen, Beomseok Cha, Kihyun Kim, Jinsoo Park, Hyun-Uk Kim, Xiangdong Yu
article en

Abstract

Magnetic bead-based surface-enhanced Raman scattering (SERS) immunoassays enable sensitive and multiplexed bacterial detection. However, bacterial targets form heterogeneous magnetic bead-bacterium-SERS nanotag immunocomplexes that vary in size, morphology, and nanotag loading. In static capillary-based measurements, different numbers of heterogeneous immunocomplexes are therefore located within the laser focal volume at each measurement position, resulting in large signal fluctuations and poor measurement reproducibility. In this study, we developed an elasto-inertial microfluidic platform that enables three-dimensional focusing of bacterial immunocomplexes for reproducible quantitative SERS measurements. Bacterial immunocomplexes suspended in 0.5% (w/v) poly(ethylene oxide) were focused near the center of a straight microchannel and continuously passed through a fixed Raman measurement region. High-speed imaging and cross-sectional Raman mapping confirmed central focusing of the immunocomplexes in both the lateral and vertical directions. Compared with static capillary-based measurements, the coefficient of variation decreased from 41.17% to 7.85% for Staphylococcus aureus and from 64.62% to 6.42% for Pseudomonas aeruginosa. The corresponding R2 values increased from 0.857 to 0.985 and from 0.680 to 0.971, respectively. The corresponding limits of detection were 2.32 × 104 CFU/mL for Staphylococcus aureus and 8.50 × 104 CFU/mL for Pseudomonas aeruginosa. The same focusing strategy was further applied to simultaneous detection of the two bacterial targets using spectrally distinguishable Raman reporters. These results demonstrate that three-dimensional elasto-inertial focusing provides an effective approach for improving the reproducibility of quantitative single- and multiplex bacterial SERS immunoassays.

ACS Sensors
Chonnam National University (KR), Chung-Ang University (KR)
Ministry of Education, Ministry of Trade, Industry and Energy, National Research Foundation of Korea
Good health and well-being
Openalex Percentile: Top 25%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.