Mathematical Analysis and Experimental Implementation of a Self-Calibration Method for Ultra-Precision Displacement Sensors

This paper starts from a revisit to the self-calibration concept of displacement sensors proposed previously by Kiyono et al. In this self-calibration scheme, two displacement sensors are used to perform a mutual calibration operation to determine their linearity error components without using a higher-accuracy reference, while their sensitivity coefficients are assumed to be known and are determined separately. A set of mathematical equations are newly established in this paper to provide a mathematical basis for the self-calibration concept. Based on the established mathematical equations, the parameters influencing the calibration results are investigated through mathematical analysis and simulation. As new findings of this paper, it is verified that the polynomial fitting errors of the discrete calibration data and the thermal drifts of the sensor outputs during the sampling process have significant impacts on the calibration results and must be carefully suppressed in practical operations. Based on these findings, a calibration system is designed and constructed for calibration experiments in which motor-driven stages are employed to shorten the calibration time and to reduce the influences of thermal drifts. The experimental results are compared with those obtained using a laser interferometer, from which the effectiveness of the constructed calibration system is verified. An Artificial Neural Network (ANN) is also introduced in this paper for fitting the calibration data containing high-frequency components instead of the conventional least-squares polynomial fitting method, which had been employed in the previous work. The self-calibration results show better repeatability than the interferometer-based calibration results. The uncertainty associated with the proposed self-calibration method was preliminarily evaluated using a Monte Carlo analysis based on experimental data.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-10-15
DOI
https://doi.org/10.3390/s26206541
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mathematical Analysis and Experimental Implementation of a Self-Calibration Method for Ultra-Precision Displacement Sensors

Ryo Sato, Wei Gao, Zhiyang Zhang, Xiaoyang Liu
Sensors
Advanced Measurement and Metrology Techniques
article

Mathematical Analysis and Experimental Implementation of a Self-Calibration Method for Ultra-Precision Displacement Sensors

Ryo Sato, Wei Gao, Zhiyang Zhang, Xiaoyang Liu
article en

Abstract

This paper starts from a revisit to the self-calibration concept of displacement sensors proposed previously by Kiyono et al. In this self-calibration scheme, two displacement sensors are used to perform a mutual calibration operation to determine their linearity error components without using a higher-accuracy reference, while their sensitivity coefficients are assumed to be known and are determined separately. A set of mathematical equations are newly established in this paper to provide a mathematical basis for the self-calibration concept. Based on the established mathematical equations, the parameters influencing the calibration results are investigated through mathematical analysis and simulation. As new findings of this paper, it is verified that the polynomial fitting errors of the discrete calibration data and the thermal drifts of the sensor outputs during the sampling process have significant impacts on the calibration results and must be carefully suppressed in practical operations. Based on these findings, a calibration system is designed and constructed for calibration experiments in which motor-driven stages are employed to shorten the calibration time and to reduce the influences of thermal drifts. The experimental results are compared with those obtained using a laser interferometer, from which the effectiveness of the constructed calibration system is verified. An Artificial Neural Network (ANN) is also introduced in this paper for fitting the calibration data containing high-frequency components instead of the conventional least-squares polynomial fitting method, which had been employed in the previous work. The self-calibration results show better repeatability than the interferometer-based calibration results. The uncertainty associated with the proposed self-calibration method was preliminarily evaluated using a Monte Carlo analysis based on experimental data.

SensorsVol. 26(20)
Tohoku University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 23%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.