Instability-Aware Digital Twins for Robust Co-Optimization of Operational Carbon Emissions, Thermal Comfort, and Structural Serviceability Reliability under Uncertainty in Smart Buildings

Modern smart buildings operate under continuously varying climatic, occupancy, equipment, grid-carbon, material, degradation, and sensing conditions, making nominal optimization insufficient for reliable operational decision-making. This study develops and numerically evaluates an instability-aware digital twin for robust co-optimization of operational carbon emissions, occupied-zone thermal discomfort, and component-level structural serviceability reliability under uncertainty. The framework combines a multi-rate thermal–energy–moisture–IAQ–structural model, carbon-aware CO₂-based ventilation control, extended Kalman filtering, Monte Carlo uncertainty propagation, FORM and design-point importance sampling, Gaussian-process surrogate modeling, NSGA-II, and dimensionless objective- and decision-instability metrics. A controlled six-zone benchmark represents a six-story office building with a gross floor area of 10,200 m² over a one-year operational horizon and a 20-year reliability horizon. Re-evaluation of the nominally selected P0 policy under the full modeled uncertainty set increased carbon emissions from 42.6 to 50.4 kgCO₂e m⁻² year⁻¹, occupied zone-time discomfort from 115 to 128 K h year⁻¹, and the serviceability limit-state exceedance probability from 0.021 to 0.031. The corresponding nominal-input underestimations were 15.5% for carbon and 32.3% for the exceedance probability. The selected robust policy produced 48.8 kgCO₂e m⁻² year⁻¹, 98 K h year⁻¹, and PSLS = 0.012, with a reliability index of 2.257. Relative to the uncertainty-aware P0 evaluation, it reduced carbon by 3.2%, discomfort by 23.4%, PSLS by 61.3%, and decision instability by 65.7%. The robust policy maintained a mean occupied zone-time CO₂ concentration of 684 ppm, a 99th percentile of 821 ppm, and zero occupied zone-hours above 1,000 ppm. Within the controlled numerical benchmark, the results show that Pareto efficiency alone does not establish operational robustness and that explicit instability quantification materially changes policy selection.

Authors

Institutions

Publication Details

Journal
Research and Reviews in Sustainability
Published
2026-10-15
DOI
https://doi.org/10.65582/rrs.2026.018
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Instability-Aware Digital Twins for Robust Co-Optimization of Operational Carbon Emissions, Thermal Comfort, and Structural Serviceability Reliability under Uncertainty in Smart Buildings

Jarek Kurnitski, Seyed Reza Samaei, James Riffat
Research and Reviews in Sustainability
Building Energy and Comfort Optimization
article

Instability-Aware Digital Twins for Robust Co-Optimization of Operational Carbon Emissions, Thermal Comfort, and Structural Serviceability Reliability under Uncertainty in Smart Buildings

Jarek Kurnitski, Seyed Reza Samaei, James Riffat
article en

Abstract

Modern smart buildings operate under continuously varying climatic, occupancy, equipment, grid-carbon, material, degradation, and sensing conditions, making nominal optimization insufficient for reliable operational decision-making. This study develops and numerically evaluates an instability-aware digital twin for robust co-optimization of operational carbon emissions, occupied-zone thermal discomfort, and component-level structural serviceability reliability under uncertainty. The framework combines a multi-rate thermal–energy–moisture–IAQ–structural model, carbon-aware CO₂-based ventilation control, extended Kalman filtering, Monte Carlo uncertainty propagation, FORM and design-point importance sampling, Gaussian-process surrogate modeling, NSGA-II, and dimensionless objective- and decision-instability metrics. A controlled six-zone benchmark represents a six-story office building with a gross floor area of 10,200 m² over a one-year operational horizon and a 20-year reliability horizon. Re-evaluation of the nominally selected P0 policy under the full modeled uncertainty set increased carbon emissions from 42.6 to 50.4 kgCO₂e m⁻² year⁻¹, occupied zone-time discomfort from 115 to 128 K h year⁻¹, and the serviceability limit-state exceedance probability from 0.021 to 0.031. The corresponding nominal-input underestimations were 15.5% for carbon and 32.3% for the exceedance probability. The selected robust policy produced 48.8 kgCO₂e m⁻² year⁻¹, 98 K h year⁻¹, and PSLS = 0.012, with a reliability index of 2.257. Relative to the uncertainty-aware P0 evaluation, it reduced carbon by 3.2%, discomfort by 23.4%, PSLS by 61.3%, and decision instability by 65.7%. The robust policy maintained a mean occupied zone-time CO₂ concentration of 684 ppm, a 99th percentile of 821 ppm, and zero occupied zone-hours above 1,000 ppm. Within the controlled numerical benchmark, the results show that Pareto efficiency alone does not establish operational robustness and that explicit instability quantification materially changes policy selection.

Research and Reviews in SustainabilityVol. 2
Tallinn University of Technology (EE), World Society of Sustainable Energy Technologies (GB)
Climate action, Sustainable cities and communities, Industry, innovation and infrastructure
Openalex Percentile: Top 16%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.