COMPARATIVE STUDY OF ELISA STOP SOLUTIONS BASED ON MINERAL ACIDS

A comparative study of ELISA stop solutions prepared on the basis of hydrochloric, orthophosphoric and sulfuric acids was performed using a competitive ELISA model for detection of antibodies against bluetongue virus. It was demonstrated that the chemical nature and concentration of the acid significantly affect the optical density of negative (K-) and positive (K+) controls, the time-dependent change of the signal, and the ratio between negative and positive controls. Hydrochloric acid solutions within the range of 0.5-4.0 M provided a high initial signal for K- (approximately 2.0 OD units), limited optical density variation over 30 minutes (3-8%), and the highest control ratio values (50-90). Orthophosphoric acid resulted in an increase of the positive control signal over time, whereas sulfuric acid caused a decrease in both K- and K+ signals, leading to narrowing of the dynamic range. The findings confirm that the selection of the stop solution is a critical factor in ELISA standardization and directly influences the analytical reliability of the diagnostic test system.

Authors

Publication Details

Journal
Eurasian journal of applied biotechnology
Published
2026-10-13
Primary Topic
Vector-Borne Animal Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARATIVE STUDY OF ELISA STOP SOLUTIONS BASED ON MINERAL ACIDS

S.E. Shomanova, B.M. Ismagambetov, N.B. Esimbekova, Z.D. Ershebulov et al.
Eurasian journal of applied biotechnology
Vector-Borne Animal Diseases
article

COMPARATIVE STUDY OF ELISA STOP SOLUTIONS BASED ON MINERAL ACIDS

S.E. Shomanova, B.M. Ismagambetov, N.B. Esimbekova, Z.D. Ershebulov, I.A. Akhazhanova
article en

Abstract

A comparative study of ELISA stop solutions prepared on the basis of hydrochloric, orthophosphoric and sulfuric acids was performed using a competitive ELISA model for detection of antibodies against bluetongue virus. It was demonstrated that the chemical nature and concentration of the acid significantly affect the optical density of negative (K-) and positive (K+) controls, the time-dependent change of the signal, and the ratio between negative and positive controls. Hydrochloric acid solutions within the range of 0.5-4.0 M provided a high initial signal for K- (approximately 2.0 OD units), limited optical density variation over 30 minutes (3-8%), and the highest control ratio values (50-90). Orthophosphoric acid resulted in an increase of the positive control signal over time, whereas sulfuric acid caused a decrease in both K- and K+ signals, leading to narrowing of the dynamic range. The findings confirm that the selection of the stop solution is a critical factor in ELISA standardization and directly influences the analytical reliability of the diagnostic test system.

Eurasian journal of applied biotechnology
Openalex Percentile: Top 8%
Vector-Borne Animal Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.