Comparison of QuantiFERON-TB Gold Plus results using ELISA and automated CLIA detection: a 39,000-sample real-world study

ABSTRACT QuantiFERON-TB Gold Plus (QFT-Plus) is a widely used interferon-γ release assay (IGRA) for the diagnosis of Mycobacterium tuberculosis infection. Recent advances introduced fully automated chemiluminescence immunoassay (CLIA) platforms as alternatives to conventional enzyme-linked immunosorbent assay (ELISA), potentially improving analytical performance and laboratory workflow. This study compared ELISA- and CLIA-based QFT-Plus assays using both lyophilized and liquid conjugate formulations in routine clinical practice. This retrospective study included 39,604 QFT-Plus assays performed during three distinct 1-year periods: 2019 (ELISA), 2023 (CLIA with lyophilized conjugate), and 2024 (CLIA with liquid conjugate). Test results were classified as positive, negative, or indeterminate. Indeterminate results were further categorized as due to low mitogen response (LMR) or high Nil value (HNV). Indeterminate results significantly decreased from 6.5% (777/11,885) with ELISA to 3.1% (394/12,690) with CLIA test using lyophilized conjugate and 3.1% (470/15,029) of CLIA tests using the liquid conjugate ( P < 0.0001). Positive results accounted for 10.6 (1,254/11,885), 10.3 (1,312/12,690), and 9.0% (1,355/15,029) of tests, respectively. Among indeterminate results, LMR accounted for 97.3% (756/777) with ELISA, whereas HNV accounted for 27.4 (108/394) and 16.8% (79/470) with the lyophilized- and liquid-conjugate CLIA methods, respectively. Agreement between TB1 and TB2 responses was consistently high across all methods (98.5–98.8%; κ = 0.92). CLIA-based QFT-Plus assays were significantly associated with a lower proportion of indeterminate results while maintaining an excellent TB1/TB2 concordance compared with ELISA. These findings support fully automated CLIA platforms as a robust and efficient alternative to conventional ELISA for high-throughput tuberculosis screening and routine clinical diagnostics. IMPORTANCE This study provides a large real-world evaluation of QuantiFERON-TB Gold Plus testing across different analytical platforms, including more than 39,000 tests performed in routine clinical practice. The transition from conventional enzyme-linked immunosorbent assay (ELISA) to automated chemiluminescence immunoassay (CLIA) was associated with an approximately 50% decrease in indeterminate results from 6.5 to 3.1%, with similarly low rates observed using both lyophilized and liquid conjugate formulations. Beyond documenting this substantial reduction, our study reveals a marked difference in the causes of indeterminate results: low mitogen response predominated with ELISA, whereas high Nil values accounted for a larger proportion of indeterminate results with CLIA. These findings, interpreted together with our previous paired-sample comparison, indicate that differences in quantitative IFN-γ measurement across platforms may affect how samples are classified against fixed decision thresholds.

Authors

Institutions

Publication Details

Journal
Microbiology Spectrum
Published
2026-10-14
DOI
https://doi.org/10.1128/spectrum.02295-26
Primary Topic
Tuberculosis Research and Epidemiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of QuantiFERON-TB Gold Plus results using ELISA and automated CLIA detection: a 39,000-sample real-world study

Giulia Lombardi, Paola Dal Monte, Alessia Cantiani, Giuliana Germinario et al.
Microbiology Spectrum
Tuberculosis Research and Epidemiology
article

Comparison of QuantiFERON-TB Gold Plus results using ELISA and automated CLIA detection: a 39,000-sample real-world study

Giulia Lombardi, Paola Dal Monte, Alessia Cantiani, Giuliana Germinario, Francesco Bisognin, Federica Sorella, Paolo Caiazza, Miriam Ciccarelli, Vincenzo Ferraro
article en

Abstract

ABSTRACT QuantiFERON-TB Gold Plus (QFT-Plus) is a widely used interferon-γ release assay (IGRA) for the diagnosis of Mycobacterium tuberculosis infection. Recent advances introduced fully automated chemiluminescence immunoassay (CLIA) platforms as alternatives to conventional enzyme-linked immunosorbent assay (ELISA), potentially improving analytical performance and laboratory workflow. This study compared ELISA- and CLIA-based QFT-Plus assays using both lyophilized and liquid conjugate formulations in routine clinical practice. This retrospective study included 39,604 QFT-Plus assays performed during three distinct 1-year periods: 2019 (ELISA), 2023 (CLIA with lyophilized conjugate), and 2024 (CLIA with liquid conjugate). Test results were classified as positive, negative, or indeterminate. Indeterminate results were further categorized as due to low mitogen response (LMR) or high Nil value (HNV). Indeterminate results significantly decreased from 6.5% (777/11,885) with ELISA to 3.1% (394/12,690) with CLIA test using lyophilized conjugate and 3.1% (470/15,029) of CLIA tests using the liquid conjugate ( P < 0.0001). Positive results accounted for 10.6 (1,254/11,885), 10.3 (1,312/12,690), and 9.0% (1,355/15,029) of tests, respectively. Among indeterminate results, LMR accounted for 97.3% (756/777) with ELISA, whereas HNV accounted for 27.4 (108/394) and 16.8% (79/470) with the lyophilized- and liquid-conjugate CLIA methods, respectively. Agreement between TB1 and TB2 responses was consistently high across all methods (98.5–98.8%; κ = 0.92). CLIA-based QFT-Plus assays were significantly associated with a lower proportion of indeterminate results while maintaining an excellent TB1/TB2 concordance compared with ELISA. These findings support fully automated CLIA platforms as a robust and efficient alternative to conventional ELISA for high-throughput tuberculosis screening and routine clinical diagnostics. IMPORTANCE This study provides a large real-world evaluation of QuantiFERON-TB Gold Plus testing across different analytical platforms, including more than 39,000 tests performed in routine clinical practice. The transition from conventional enzyme-linked immunosorbent assay (ELISA) to automated chemiluminescence immunoassay (CLIA) was associated with an approximately 50% decrease in indeterminate results from 6.5 to 3.1%, with similarly low rates observed using both lyophilized and liquid conjugate formulations. Beyond documenting this substantial reduction, our study reveals a marked difference in the causes of indeterminate results: low mitogen response predominated with ELISA, whereas high Nil values accounted for a larger proportion of indeterminate results with CLIA. These findings, interpreted together with our previous paired-sample comparison, indicate that differences in quantitative IFN-γ measurement across platforms may affect how samples are classified against fixed decision thresholds.

Microbiology Spectrum
IRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola (IT), University of Bologna (IT)
Good health and well-being
Openalex Percentile: Top 12%
Tuberculosis Research and Epidemiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.