Ultrasensitive and Specific Detection of Neutralization-Correlated Serum Antibodies Via Secondary Antibody−DNA Linker-Mediated Magnetic Bead−Based Proximity Extension Assay

Abstract Sensitive, accurate, and readily deployable detection of neutralizing antibody (NAb) titers is essential for evaluating vaccine efficacy and population-level immunity. Here, we report an Antibody-DNA Linker (AND Linker) comprising a fusion of Protein A/G, a G4S flexible peptide, and duck circovirus replication initiator protein (DCV). This design enables orthogonal, site-specific assembly: the N-terminal Protein A/G binds the IgG Fc region, while the C-terminal DCV covalently captures 5′ ssDNA at a defined 1:1 molar ratio. Unlike random chemical crosslinking, which suffers from heterogeneous attachment sites, variable stoichiometry, and poor reproducibility, the AND Linker ensures uniform functional orientation and minimal batch-to-batch variation. By optimizing ssDNA secondary structure, we further enhanced DCV recognition efficiency. Integrating this linker into a magnetic bead-based proximity extension assay (termed SADL-MPEA), we achieved femtomolar-level detection of serum antibodies highly correlated with neutralizing activity. For HPV16 and HPV18, SADL-MPEA demonstrated limits of detection (LOD) approximately three orders of magnitude lower than conventional PEA using random chemical conjugation. In clinical serum validation against the pseudovirus neutralization test (PBNT), SADL-MPEA showed strong concordance (Pearson’s r = 0.84−0.85), confirming its utility as a reliable surrogate for functional neutralization capacity. Diagnostic performance was exceptional, with sensitivities of 90.9% (HPV16) and 83.3% (HPV18), 100% specificity for both, and an area under the ROC curve of 0.99. Crucially, SADL-MPEA requires only antigen-coated magnetic beads to adapt to new targets, as the DNA-labeled secondary antibody remains universal. This platform offers a simple, high-throughput, and scalable solution for NAb-correlated antibody detection in research and clinical settings.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-10-14
DOI
https://doi.org/10.1021/acs.analchem.6c03485
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive and Specific Detection of Neutralization-Correlated Serum Antibodies Via Secondary Antibody−DNA Linker-Mediated Magnetic Bead−Based Proximity Extension Assay

Feng Ye, Xiao Lin, Yujue Wang, Shiyu Cao et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

Ultrasensitive and Specific Detection of Neutralization-Correlated Serum Antibodies Via Secondary Antibody−DNA Linker-Mediated Magnetic Bead−Based Proximity Extension Assay

Feng Ye, Xiao Lin, Yujue Wang, Shiyu Cao, Wei Wang, Long Zhao
article en

Abstract

Abstract Sensitive, accurate, and readily deployable detection of neutralizing antibody (NAb) titers is essential for evaluating vaccine efficacy and population-level immunity. Here, we report an Antibody-DNA Linker (AND Linker) comprising a fusion of Protein A/G, a G4S flexible peptide, and duck circovirus replication initiator protein (DCV). This design enables orthogonal, site-specific assembly: the N-terminal Protein A/G binds the IgG Fc region, while the C-terminal DCV covalently captures 5′ ssDNA at a defined 1:1 molar ratio. Unlike random chemical crosslinking, which suffers from heterogeneous attachment sites, variable stoichiometry, and poor reproducibility, the AND Linker ensures uniform functional orientation and minimal batch-to-batch variation. By optimizing ssDNA secondary structure, we further enhanced DCV recognition efficiency. Integrating this linker into a magnetic bead-based proximity extension assay (termed SADL-MPEA), we achieved femtomolar-level detection of serum antibodies highly correlated with neutralizing activity. For HPV16 and HPV18, SADL-MPEA demonstrated limits of detection (LOD) approximately three orders of magnitude lower than conventional PEA using random chemical conjugation. In clinical serum validation against the pseudovirus neutralization test (PBNT), SADL-MPEA showed strong concordance (Pearson’s r = 0.84−0.85), confirming its utility as a reliable surrogate for functional neutralization capacity. Diagnostic performance was exceptional, with sensitivities of 90.9% (HPV16) and 83.3% (HPV18), 100% specificity for both, and an area under the ROC curve of 0.99. Crucially, SADL-MPEA requires only antigen-coated magnetic beads to adapt to new targets, as the DNA-labeled secondary antibody remains universal. This platform offers a simple, high-throughput, and scalable solution for NAb-correlated antibody detection in research and clinical settings.

Analytical Chemistry
Sichuan University (CN), Institute for the Future (US), Future Earth (CA)
Good health and well-being
Openalex Percentile: Top 24%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.