Salvaging a Telescopic-Crown-Retained Partial Denture Using a Novel Flexible Attachment System—A Case Report

Background and Clinical Significance: Removable partial dentures still present a relevant treatment option in an aging population. With the exception of clasps, the vast majority of attachment systems available for anchoring these restorations on natural abutments requires invasive tooth preparations causing secondary problems such as caries and abutment tooth fractures. In cases where an abutment tooth cannot be salvaged, placing an implant and connecting the existing prosthesis to this implant presents a viable solution. While a common path of insertion has been established during initial fabrication, it is almost impossible to match this with a newly placed retentive element. In the case presented, a novel ball anchor that allows for compensatory movements was used as a retentive implant abutment for salvaging a removable partial prosthesis. Case Presentation: An 83-year-old, medically compromised male patient, restored with a removable partial denture, stabilized by one abutment tooth and two clasps in the mandible, suffered from a non-restorable fracture of the abutment tooth. After tooth extraction, immediate implant placement (MT implant, AlfaGate, Bonn, Germany), closed healing of the implant for three month, then second-stage implant surgery and soft tissue healing for another four weeks, the implant was connected to a novel flexible attachment system, the REFLEX abutment (Hader Solutions, Dublin, Ireland). Shaped as a retentive ball, the REFLEX abutment allows lateral movements of the male attachment part while maintaining vertical dimensions like rigid locator-type attachments. Conclusions: The retrofitting of the novel flexible attachment under an originally telescopic-crown-retained partial denture allowed for a successful conversion of the prosthesis while preserving prosthetic fit and retention for the patient.

Authors

Institutions

Publication Details

Journal
Reports — Medical Cases Images and Videos
Published
2026-10-14
DOI
https://doi.org/10.3390/reports9040354
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Salvaging a Telescopic-Crown-Retained Partial Denture Using a Novel Flexible Attachment System—A Case Report

Rainer Lutz, Christian Behle, Maya Brink, Florian Lipka et al.
Reports — Medical Cases Images and Videos
Dental Implant Techniques and Outcomes
article

Salvaging a Telescopic-Crown-Retained Partial Denture Using a Novel Flexible Attachment System—A Case Report

Rainer Lutz, Christian Behle, Maya Brink, Florian Lipka, Sarah-Maria Meier
article en

Abstract

Background and Clinical Significance: Removable partial dentures still present a relevant treatment option in an aging population. With the exception of clasps, the vast majority of attachment systems available for anchoring these restorations on natural abutments requires invasive tooth preparations causing secondary problems such as caries and abutment tooth fractures. In cases where an abutment tooth cannot be salvaged, placing an implant and connecting the existing prosthesis to this implant presents a viable solution. While a common path of insertion has been established during initial fabrication, it is almost impossible to match this with a newly placed retentive element. In the case presented, a novel ball anchor that allows for compensatory movements was used as a retentive implant abutment for salvaging a removable partial prosthesis. Case Presentation: An 83-year-old, medically compromised male patient, restored with a removable partial denture, stabilized by one abutment tooth and two clasps in the mandible, suffered from a non-restorable fracture of the abutment tooth. After tooth extraction, immediate implant placement (MT implant, AlfaGate, Bonn, Germany), closed healing of the implant for three month, then second-stage implant surgery and soft tissue healing for another four weeks, the implant was connected to a novel flexible attachment system, the REFLEX abutment (Hader Solutions, Dublin, Ireland). Shaped as a retentive ball, the REFLEX abutment allows lateral movements of the male attachment part while maintaining vertical dimensions like rigid locator-type attachments. Conclusions: The retrofitting of the novel flexible attachment under an originally telescopic-crown-retained partial denture allowed for a successful conversion of the prosthesis while preserving prosthetic fit and retention for the patient.

Reports — Medical Cases Images and VideosVol. 9(4)
Philipps University of Marburg (DE)
Good health and well-being
Openalex Percentile: Top 10%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.