Experimental behaviour of cold-formed steel and concrete composite beams with innovative shear connections

Steel and concrete composite beams can be designed to reduce labour, materials, costs and constructions errors, optimising the structural solution. This work experimentally examines two innovative connection systems for cold-formed steel (CFS) and concrete composite floors: HCO (Half-circular Opening) and TBU (Triangular Bent-up) connections. HCO and TBU connections are made of cuts and bend-ups in the CFS profiles, minimising material use and labour required for the application of conventional mechanical shear connectors. Bending tests were conducted on simply supported composite beams, under short-term loading, to assess the load-deflection behaviour, horizontal end slip, strain distribution across the cross-section and failure modes. A group of reference specimens, where the CFS profiles were bolted (type B), was tested without the proposed connections. During the tests, the following aspects were evaluated: connection type (HCO or TBU), assembly method (bolting or welding), span length (1.2 m and 1.8 m) and loading configuration (three and four loading points). The results show that the span length and loading configuration influence the distribution of horizontal slip. Slip limited the load capacity of 1.2 m span beams. This restriction was overcome using HCO and TBU connections. Furthermore, the TBU connection increased the maximum load and deflection capacities in 5.9% and 302.0%, respectively, for the 1.2 m beams, and in 4.8% and 1.8%, respectively, for the 1.8 m beams, compared to the corresponding reference specimens (type B). These responses were not observed with the HCO connection. Therefore, the main improvement was in the deformation capacity of the TBU beams with 1.2 m. All composite beams failed due to interlaminar shear debonding between CFS and concrete (interface horizontal shear failure) and concrete diagonal shear cracks.

Authors

Institutions

Publication Details

Journal
Structures
Published
2026-10-14
DOI
https://doi.org/10.1016/j.istruc.2026.113268
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental behaviour of cold-formed steel and concrete composite beams with innovative shear connections

Joaquim A. O. Barros, Talita L. Silva, Isabel Brito Valente, Hidelbrando José Farkat Diógenes
Structures
Structural Load-Bearing Analysis
article

Experimental behaviour of cold-formed steel and concrete composite beams with innovative shear connections

Joaquim A. O. Barros, Talita L. Silva, Isabel Brito Valente, Hidelbrando José Farkat Diógenes
article en

Abstract

Steel and concrete composite beams can be designed to reduce labour, materials, costs and constructions errors, optimising the structural solution. This work experimentally examines two innovative connection systems for cold-formed steel (CFS) and concrete composite floors: HCO (Half-circular Opening) and TBU (Triangular Bent-up) connections. HCO and TBU connections are made of cuts and bend-ups in the CFS profiles, minimising material use and labour required for the application of conventional mechanical shear connectors. Bending tests were conducted on simply supported composite beams, under short-term loading, to assess the load-deflection behaviour, horizontal end slip, strain distribution across the cross-section and failure modes. A group of reference specimens, where the CFS profiles were bolted (type B), was tested without the proposed connections. During the tests, the following aspects were evaluated: connection type (HCO or TBU), assembly method (bolting or welding), span length (1.2 m and 1.8 m) and loading configuration (three and four loading points). The results show that the span length and loading configuration influence the distribution of horizontal slip. Slip limited the load capacity of 1.2 m span beams. This restriction was overcome using HCO and TBU connections. Furthermore, the TBU connection increased the maximum load and deflection capacities in 5.9% and 302.0%, respectively, for the 1.2 m beams, and in 4.8% and 1.8%, respectively, for the 1.8 m beams, compared to the corresponding reference specimens (type B). These responses were not observed with the HCO connection. Therefore, the main improvement was in the deformation capacity of the TBU beams with 1.2 m. All composite beams failed due to interlaminar shear debonding between CFS and concrete (interface horizontal shear failure) and concrete diagonal shear cracks.

StructuresVol. 94
Universidade Federal da Paraíba (BR), University of Minho (PT)
Fundação para a Ciência e a Tecnologia
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.