Effect of polyethylene and glass fiber reinforcement on the radiopacity of flowable resin composites: an in-vitro comparative study

Chairside fiber reinforcement of flowable composites may alter their radiographic behavior, yet different fiber systems have not been directly compared within the same composite matrix. This study compared a polyethylene fiber mesh (Ribbond) and a pre-impregnated glass fiber strip (EverStick) for their effect on the radiopacity of two flowable composites with different filler systems. Clearfil Majesty Flow (CMF; barium glass, 81 wt%) and G-aenial Universal Injectable (GAI; strontium/lanthanoid glass, 69 wt%) served as negative controls and EverX Flow (EXF), a factory short-fiber-reinforced composite, as positive control. Ribbond (polyethylene mesh) and EverStick (pre-impregnated glass fiber strip) were incorporated as single 4 × 2 mm interlayers in disc specimens (10 mm × 2 mm; n = 5 per group). Aluminum-equivalent radiopacity (mmAl) was calculated from digital radiographs using ImageJ. Enamel and dentin sections from one extracted third molar served as descriptive references. Data were analyzed by one-way and two-way ANOVA with Tukey HSD tests (α = 0.05); effect sizes and 95% confidence intervals were reported. Significant differences existed among the measured series [F(8, 36) = 335.03, p < 0.001, ηp² = 0.987]. EverStick reduced radiopacity by 40.3% in CMF (7.66 ± 0.25 to 4.58 ± 0.27 mmAl) and by 32.4% in GAI (3.94 ± 0.24 to 2.66 ± 0.22 mmAl; p < 0.001 for both). Ribbond did not significantly alter radiopacity ( p > 0.05). Two-way ANOVA of the six composite groups confirmed significant main effects and interaction ( p < 0.001). All groups exceeded the ISO 4049 minimum (≥ 2.0 mmAl); GAI + EverStick produced the lowest mean (2.66 mmAl) and was numerically lower than the enamel reference (4.11 ± 0.27 mmAl). Ribbond produced no statistically detectable change in radiopacity in either composite background, whereas EverStick reduced it significantly. The differences were statistically significant, but all constructs still met the ISO 4049 requirement and no diagnostic-accuracy assessment was performed, so a clinical consequence remains to be demonstrated. The difference between the two systems most plausibly reflects their combined properties — fiber composition, bundle dimensions, resin pre-impregnation and adhesive infiltration — rather than fiber type alone. Radiographic behavior may reasonably be considered alongside mechanical performance when a reinforcement system is selected.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-10-14
DOI
https://doi.org/10.1186/s12903-026-10047-5
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of polyethylene and glass fiber reinforcement on the radiopacity of flowable resin composites: an in-vitro comparative study

Neslihan Tekçe, Göktuğ Yersel, Zeynep Tuba Kılıç
BMC Oral Health
Dental materials and restorations
article

Effect of polyethylene and glass fiber reinforcement on the radiopacity of flowable resin composites: an in-vitro comparative study

Neslihan Tekçe, Göktuğ Yersel, Zeynep Tuba Kılıç
article en

Abstract

Chairside fiber reinforcement of flowable composites may alter their radiographic behavior, yet different fiber systems have not been directly compared within the same composite matrix. This study compared a polyethylene fiber mesh (Ribbond) and a pre-impregnated glass fiber strip (EverStick) for their effect on the radiopacity of two flowable composites with different filler systems. Clearfil Majesty Flow (CMF; barium glass, 81 wt%) and G-aenial Universal Injectable (GAI; strontium/lanthanoid glass, 69 wt%) served as negative controls and EverX Flow (EXF), a factory short-fiber-reinforced composite, as positive control. Ribbond (polyethylene mesh) and EverStick (pre-impregnated glass fiber strip) were incorporated as single 4 × 2 mm interlayers in disc specimens (10 mm × 2 mm; n = 5 per group). Aluminum-equivalent radiopacity (mmAl) was calculated from digital radiographs using ImageJ. Enamel and dentin sections from one extracted third molar served as descriptive references. Data were analyzed by one-way and two-way ANOVA with Tukey HSD tests (α = 0.05); effect sizes and 95% confidence intervals were reported. Significant differences existed among the measured series [F(8, 36) = 335.03, p < 0.001, ηp² = 0.987]. EverStick reduced radiopacity by 40.3% in CMF (7.66 ± 0.25 to 4.58 ± 0.27 mmAl) and by 32.4% in GAI (3.94 ± 0.24 to 2.66 ± 0.22 mmAl; p < 0.001 for both). Ribbond did not significantly alter radiopacity ( p > 0.05). Two-way ANOVA of the six composite groups confirmed significant main effects and interaction ( p < 0.001). All groups exceeded the ISO 4049 minimum (≥ 2.0 mmAl); GAI + EverStick produced the lowest mean (2.66 mmAl) and was numerically lower than the enamel reference (4.11 ± 0.27 mmAl). Ribbond produced no statistically detectable change in radiopacity in either composite background, whereas EverStick reduced it significantly. The differences were statistically significant, but all constructs still met the ISO 4049 requirement and no diagnostic-accuracy assessment was performed, so a clinical consequence remains to be demonstrated. The difference between the two systems most plausibly reflects their combined properties — fiber composition, bundle dimensions, resin pre-impregnation and adhesive infiltration — rather than fiber type alone. Radiographic behavior may reasonably be considered alongside mechanical performance when a reinforcement system is selected.

BMC Oral Health
Kocaeli Üniversitesi (TR)
Good health and well-being
Openalex Percentile: Top 10%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.