Deep Learning-Based Multiple Sclerosis Lesion Segmentation at 7 Tesla: Comparison of Single- and Multi-Contrast MRI Inputs

Automated lesion segmentation can support rapid and reproducible quantitative assessment and long-term monitoring of multiple sclerosis. Ultra-high-field 7T MRI provides increased spatial resolution and lesion visibility but introduces challenges for automated analysis, including field inhomogeneity, susceptibility-related artifacts, and spatially varying image contrast. Although deep learning methods perform well at conventional field strengths, their application to 7T MRI remains underexplored. We evaluated nnUNet using FLAIR alone, MP2RAGE alone, and combined MP2RAGE+FLAIR. The dataset included 115 longitudinal 7T MRI scans from 57 patients with MS, with 20 scans from 11 independent patients reserved for testing. DeepMedic was included as a comparative architecture. On the test set, nnUNet achieved mean DSC values of 0.72, 0.71, and 0.66 for combined, MP2RAGE-only, and FLAIR-only inputs, respectively. No significant DSC differences were observed between nnUNet and DeepMedic. For both architectures, adding FLAIR to MP2RAGE did not show a statistically significant additional benefit in the present test cohort, whereas MP2RAGE-containing inputs significantly outperformed FLAIR-only input. The findings of the present study provide preliminary evidence suggesting that the observed voxel-level segmentation performance was primarily associated with the inclusion of MP2RAGE. However, lesion-level performance depended on lesion size, indicating further investigation of contrast-specific effects on small-lesion detection.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2026-10-14
DOI
https://doi.org/10.3390/jimaging12100510
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning-Based Multiple Sclerosis Lesion Segmentation at 7 Tesla: Comparison of Single- and Multi-Contrast MRI Inputs

Eva Niess, Günther Grabner, Wolfgang Bogner, Stanislav Motyka et al.
Journal of Imaging
Medical Image Segmentation Techniques
article

Deep Learning-Based Multiple Sclerosis Lesion Segmentation at 7 Tesla: Comparison of Single- and Multi-Contrast MRI Inputs

Eva Niess, Günther Grabner, Wolfgang Bogner, Stanislav Motyka, Paulus Stefan Rommer, Gabriel Bsteh, Lukas Haider, Bernhard Strasser, Thomas Berger, Assunta Dal‐Bianco, Joel Leinkauf, Ivan Petrović, Rebeka Rumbak, Yanniklas Kravutske, Marc Berger, Anna Petrova
article en

Abstract

Automated lesion segmentation can support rapid and reproducible quantitative assessment and long-term monitoring of multiple sclerosis. Ultra-high-field 7T MRI provides increased spatial resolution and lesion visibility but introduces challenges for automated analysis, including field inhomogeneity, susceptibility-related artifacts, and spatially varying image contrast. Although deep learning methods perform well at conventional field strengths, their application to 7T MRI remains underexplored. We evaluated nnUNet using FLAIR alone, MP2RAGE alone, and combined MP2RAGE+FLAIR. The dataset included 115 longitudinal 7T MRI scans from 57 patients with MS, with 20 scans from 11 independent patients reserved for testing. DeepMedic was included as a comparative architecture. On the test set, nnUNet achieved mean DSC values of 0.72, 0.71, and 0.66 for combined, MP2RAGE-only, and FLAIR-only inputs, respectively. No significant DSC differences were observed between nnUNet and DeepMedic. For both architectures, adding FLAIR to MP2RAGE did not show a statistically significant additional benefit in the present test cohort, whereas MP2RAGE-containing inputs significantly outperformed FLAIR-only input. The findings of the present study provide preliminary evidence suggesting that the observed voxel-level segmentation performance was primarily associated with the inclusion of MP2RAGE. However, lesion-level performance depended on lesion size, indicating further investigation of contrast-specific effects on small-lesion detection.

Journal of ImagingVol. 12(10)
Christian Doppler Laboratory for Thermoelectricity (AT), FH Kärnten (AT), National Hospital for Neurology and Neurosurgery (GB), UCL Queen Square Institute of Neurology (GB), University College London (GB), Medical University of Vienna (AT)
Good health and well-being
Openalex Percentile: Top 16%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.