Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas

Abstract Objective To investigate the effect of the implantable collamer lens (ICL) on biometric measurements and intraocular lens (IOL) power calculation formulas. Methods This prospective theoretical study included 92 eyes undergoing ICL surgery. Preoperative and 1‐year postoperative biometric parameters, including axial length (AL), keratometry (K), anterior‐chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT) and corneal diameter (CD), were measured using IOLMaster 700. Nine formula types (10 variants) were evaluated: Barrett Universal II (BU II; BU II a , IOLMaster 700‐based; BU II b , online calculator), Cooke K6, EVO, Hill‐RBF, Hoffer QST, Holladay 1, Kane, Pearl‐DGS and SRK/T. Primary outcomes were the difference in predicted spherical equivalent before and after ICL implantation (Δ‐pSEQ) and the percentage of eyes within specified Δ‐pSEQ ranges. Results For all eyes ( n = 92), significant post‐ICL changes included increased AL, steep K (K2), LT, CCT (+0.02 mm, +0.08 D, +0.26 mm, +0.003 mm; p = 0.031, 0.021, <0.001, 0.008) and decreased ACD (−0.28 mm, p < 0.001). ACD segmentation errors occurred in 34.78% of eyes, associated with low vault (optimal cut‐off, 0.491 mm; AUC = 0.921). Eyes were grouped by segmentation accuracy (correct, n = 60; incorrect, n = 32). All Δ‐pSEQ values were within ±0.50 D; between‐subgroup differences in Δ‐pSEQ ranges were not significant ( p > 0.05). The highest proportions within ±0.25 D were SRK/T (86% overall, 94% incorrect group) and BU II a (85% correct group); EVO had the lowest (71%–72%). Conclusion ICL implantation alters biometric measurements and theoretically predicted Δ‐pSEQ; although these changes are statistically significant, their clinical significance is negligible. While incorrect ACD segmentation is common, it is unlikely to substantially affect the theoretical calculation results.

Authors

Institutions

Publication Details

Journal
Acta Ophthalmologica
Published
2026-10-14
DOI
https://doi.org/10.1111/aos.70259
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas

An-Peng Pan, A‐Yong Yu, Jingfeng Zhao, Jun Hu et al.
Acta Ophthalmologica
Intraocular Surgery and Lenses
article

Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas

An-Peng Pan, A‐Yong Yu, Jingfeng Zhao, Jun Hu, Zi‐Yue Li, Wan‐Ping Zhang, Yong‐Zheng Qu, An‐Song Li, Lin‐Hua Chen
article en

Abstract

Abstract Objective To investigate the effect of the implantable collamer lens (ICL) on biometric measurements and intraocular lens (IOL) power calculation formulas. Methods This prospective theoretical study included 92 eyes undergoing ICL surgery. Preoperative and 1‐year postoperative biometric parameters, including axial length (AL), keratometry (K), anterior‐chamber depth (ACD), lens thickness (LT), central corneal thickness (CCT) and corneal diameter (CD), were measured using IOLMaster 700. Nine formula types (10 variants) were evaluated: Barrett Universal II (BU II; BU II a , IOLMaster 700‐based; BU II b , online calculator), Cooke K6, EVO, Hill‐RBF, Hoffer QST, Holladay 1, Kane, Pearl‐DGS and SRK/T. Primary outcomes were the difference in predicted spherical equivalent before and after ICL implantation (Δ‐pSEQ) and the percentage of eyes within specified Δ‐pSEQ ranges. Results For all eyes ( n = 92), significant post‐ICL changes included increased AL, steep K (K2), LT, CCT (+0.02 mm, +0.08 D, +0.26 mm, +0.003 mm; p = 0.031, 0.021, <0.001, 0.008) and decreased ACD (−0.28 mm, p < 0.001). ACD segmentation errors occurred in 34.78% of eyes, associated with low vault (optimal cut‐off, 0.491 mm; AUC = 0.921). Eyes were grouped by segmentation accuracy (correct, n = 60; incorrect, n = 32). All Δ‐pSEQ values were within ±0.50 D; between‐subgroup differences in Δ‐pSEQ ranges were not significant ( p > 0.05). The highest proportions within ±0.25 D were SRK/T (86% overall, 94% incorrect group) and BU II a (85% correct group); EVO had the lowest (71%–72%). Conclusion ICL implantation alters biometric measurements and theoretically predicted Δ‐pSEQ; although these changes are statistically significant, their clinical significance is negligible. While incorrect ACD segmentation is common, it is unlikely to substantially affect the theoretical calculation results.

Acta Ophthalmologica
Wenzhou Medical University (CN), Wuhan University (CN), Tongji Hospital (CN), Huazhong University of Science and Technology (CN)
National Key Research and Development Program of China
Good health and well-being
Openalex Percentile: Top 9%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.