Cancer Tissue Fraction as a Scanner-Robust Triage Signal for Automated Gleason Grading of Prostate Biopsies: External Validation Across a Middle Eastern Cohort

Background: Deep learning systems for Gleason grading are developed almost entirely on high-end clinical scanners and on cohorts from a small number of Western institutions, yet deployment increasingly involves other devices and other populations. These two distribution shifts, device and population, are rarely tested together on the same physical slides. The PAR dataset, from Erbil, Iraq, digitizes each biopsy on three scanners and provides three distinct pathologist grades, so it permits both tests at once on a Middle Eastern cohort. A concurrent study by the dataset originators validated a task-specific model and two foundation models on PAR; we complement it by testing an independently developed detect-then-grade pipeline and by separating scanner effects on detection from scanner effects on grading. Methods: We applied one fixed model developed on North American and European material to all 1017 whole-slide images (339 slides from 185 patients, three scanners; 49.6% clinically significant cancer) with no scanner-specific or population-specific tuning. We measured cancer detection (area under the ROC curve of the predicted cancer tissue fraction), all-slide ISUP agreement of the deployed detect-then-grade pipeline (quadratic-weighted kappa, QWK), and grading agreement on pathologist-confirmed cancers, at the slide level and, because a case carries up to two slides, at the patient level. The reference reader was S.A.; thresholds and operating points were cross-validated leave-one-out; scanners were compared by paired within-biopsy bootstrap and confidence intervals confirmed by patient-cluster bootstrap. Results: Detection was statistically equivalent across scanners (AUC 0.987 to 0.991; paired differences at most 0.003) and transferred to this non-Western cohort with no per-population tuning. At a 95% sensitivity operating point, the deployed pipeline reached cross-validated all-slide QWK of 0.86, 0.81, and 0.86 (Grundium, Hamamatsu, Leica), matching the inter-pathologist ceiling of 0.81, against 0.23 to 0.62 for the ungated model. Grading of confirmed cancers was scanner-dependent: the compact Grundium (0.63) did not differ from the clinical Leica (0.67; paired difference 0.04, 95% CI −0.03 to 0.11), while both exceeded Hamamatsu (0.44). Results held at the patient level, with grading somewhat lower for two scanners; the two slides of a case disagreed in grade in 43% of cases, and patient clustering did not widen the intervals. Conclusions: Cancer tissue fraction is a triage signal robust across scanner and transferable to an underrepresented population for detection, while grading is the scanner-sensitive step. Prostate grading models should be deployed as a detect-then-grade pipeline, with grading validated per device and confirmed on the local population.

Authors

Institutions

Publication Details

Journal
Uro
Published
2026-10-14
DOI
https://doi.org/10.3390/uro6040028
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cancer Tissue Fraction as a Scanner-Robust Triage Signal for Automated Gleason Grading of Prostate Biopsies: External Validation Across a Middle Eastern Cohort

Anthony S. Perry, Dennis Della Corte, Jared Szymanski, Joshua L. Ebbert
Uro
AI in cancer detection
article

Cancer Tissue Fraction as a Scanner-Robust Triage Signal for Automated Gleason Grading of Prostate Biopsies: External Validation Across a Middle Eastern Cohort

Anthony S. Perry, Dennis Della Corte, Jared Szymanski, Joshua L. Ebbert
article en

Abstract

Background: Deep learning systems for Gleason grading are developed almost entirely on high-end clinical scanners and on cohorts from a small number of Western institutions, yet deployment increasingly involves other devices and other populations. These two distribution shifts, device and population, are rarely tested together on the same physical slides. The PAR dataset, from Erbil, Iraq, digitizes each biopsy on three scanners and provides three distinct pathologist grades, so it permits both tests at once on a Middle Eastern cohort. A concurrent study by the dataset originators validated a task-specific model and two foundation models on PAR; we complement it by testing an independently developed detect-then-grade pipeline and by separating scanner effects on detection from scanner effects on grading. Methods: We applied one fixed model developed on North American and European material to all 1017 whole-slide images (339 slides from 185 patients, three scanners; 49.6% clinically significant cancer) with no scanner-specific or population-specific tuning. We measured cancer detection (area under the ROC curve of the predicted cancer tissue fraction), all-slide ISUP agreement of the deployed detect-then-grade pipeline (quadratic-weighted kappa, QWK), and grading agreement on pathologist-confirmed cancers, at the slide level and, because a case carries up to two slides, at the patient level. The reference reader was S.A.; thresholds and operating points were cross-validated leave-one-out; scanners were compared by paired within-biopsy bootstrap and confidence intervals confirmed by patient-cluster bootstrap. Results: Detection was statistically equivalent across scanners (AUC 0.987 to 0.991; paired differences at most 0.003) and transferred to this non-Western cohort with no per-population tuning. At a 95% sensitivity operating point, the deployed pipeline reached cross-validated all-slide QWK of 0.86, 0.81, and 0.86 (Grundium, Hamamatsu, Leica), matching the inter-pathologist ceiling of 0.81, against 0.23 to 0.62 for the ungated model. Grading of confirmed cancers was scanner-dependent: the compact Grundium (0.63) did not differ from the clinical Leica (0.67; paired difference 0.04, 95% CI −0.03 to 0.11), while both exceeded Hamamatsu (0.44). Results held at the patient level, with grading somewhat lower for two scanners; the two slides of a case disagreed in grade in 43% of cases, and patient clustering did not widen the intervals. Conclusions: Cancer tissue fraction is a triage signal robust across scanner and transferable to an underrepresented population for detection, while grading is the scanner-sensitive step. Prostate grading models should be deployed as a detect-then-grade pipeline, with grading validated per device and confirmed on the local population.

UroVol. 6(4)
Brigham Young University (US)
Good health and well-being
Openalex Percentile: Top 13%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.