Clinical evaluation of different arthrocentesis techniques in the treatment of temporomandibular joint disorders

Temporomandibular joint arthrocentesis has undergone several technical modifications aimed at simplifying joint access and improving procedural efficiency. However, some single-puncture techniques require specially manufactured cannula systems that may not be readily available in all clinical settings. This study compared the intraoperative performance and clinical outcomes of a manually assembled, unsoldered Y-shaped double-puncture arthrocentesis technique using standard needles with those of single-puncture arthrocentesis using a prefabricated soldered Y-shaped cannula in patients with Wilkes stage II–III temporomandibular disorders. This retrospective study included 50 patients with unilateral Wilkes stage II–III temporomandibular disorders who had not responded to at least six months of conservative treatment. Group 1 ( n = 25) underwent double-puncture arthrocentesis using two standard 22-gauge needles manually bent and assembled into an unsoldered Y-shaped configuration, whereas Group 2 ( n = 25) underwent single-puncture arthrocentesis using a prefabricated soldered Y-shaped cannula. Intraoperative parameters and clinical outcomes were evaluated preoperatively and at 1 and 6 months postoperatively. Cross-sectional intergroup comparisons at each evaluation period were performed using the Mann–Whitney U test, Chi-square test, or Fisher’s exact test, as appropriate. Both techniques resulted in significant postoperative improvements in functional and clinical outcomes. Single-puncture arthrocentesis with the prefabricated Y-shaped cannula required significantly fewer needle insertion attemps than the manually assembled technique ( p = 0.049), whereas procedure duration, intraoperative complications, and treatment tolerance did not differ significantly between groups. No significant between-group differences in functional movements, pain intensity, or self-reported masticatory function were observed preoperatively or at 1 month. At 6 months, protrusive movement was significantly greater in Group 1 ( p = 0.035), whereas self-reported masticatory function was significantly higher in Group 2 ( p = 0.015). Other evaluated clinical symptoms showed no significant between-group differences during follow-up. Within the limitations of this retrospective study, no statistically significant between-group differences were detected for most assessed clinical outcomes. Double-puncture arthrocentesis using a manually assembled unsoldered Y-shaped configuration required more needle insertion attempts, while isolated differences at 6 months favored DPA for protrusive movement and SPA Type II for self-reported masticatory function. The manually assembled configuration may represent a practical and accessible option for temporomandibular joint arthrocentesis when prefabricated cannula systems are unavailable. These findings should not be interpreted as demonstrating equivalence or superiority of either technique. ClinicalTrials.gov, NCT07327099; retrospectively registered on (24.12.2025).

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-10-14
DOI
https://doi.org/10.1186/s12903-026-10190-z
Primary Topic
Temporomandibular Joint Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical evaluation of different arthrocentesis techniques in the treatment of temporomandibular joint disorders

Ayşe Bayraktar, Mehmet Fatih Şentürk, Cem Üngör, Helin Merve Özalp
BMC Oral Health
Temporomandibular Joint Disorders
article

Clinical evaluation of different arthrocentesis techniques in the treatment of temporomandibular joint disorders

Ayşe Bayraktar, Mehmet Fatih Şentürk, Cem Üngör, Helin Merve Özalp
article en

Abstract

Temporomandibular joint arthrocentesis has undergone several technical modifications aimed at simplifying joint access and improving procedural efficiency. However, some single-puncture techniques require specially manufactured cannula systems that may not be readily available in all clinical settings. This study compared the intraoperative performance and clinical outcomes of a manually assembled, unsoldered Y-shaped double-puncture arthrocentesis technique using standard needles with those of single-puncture arthrocentesis using a prefabricated soldered Y-shaped cannula in patients with Wilkes stage II–III temporomandibular disorders. This retrospective study included 50 patients with unilateral Wilkes stage II–III temporomandibular disorders who had not responded to at least six months of conservative treatment. Group 1 ( n = 25) underwent double-puncture arthrocentesis using two standard 22-gauge needles manually bent and assembled into an unsoldered Y-shaped configuration, whereas Group 2 ( n = 25) underwent single-puncture arthrocentesis using a prefabricated soldered Y-shaped cannula. Intraoperative parameters and clinical outcomes were evaluated preoperatively and at 1 and 6 months postoperatively. Cross-sectional intergroup comparisons at each evaluation period were performed using the Mann–Whitney U test, Chi-square test, or Fisher’s exact test, as appropriate. Both techniques resulted in significant postoperative improvements in functional and clinical outcomes. Single-puncture arthrocentesis with the prefabricated Y-shaped cannula required significantly fewer needle insertion attemps than the manually assembled technique ( p = 0.049), whereas procedure duration, intraoperative complications, and treatment tolerance did not differ significantly between groups. No significant between-group differences in functional movements, pain intensity, or self-reported masticatory function were observed preoperatively or at 1 month. At 6 months, protrusive movement was significantly greater in Group 1 ( p = 0.035), whereas self-reported masticatory function was significantly higher in Group 2 ( p = 0.015). Other evaluated clinical symptoms showed no significant between-group differences during follow-up. Within the limitations of this retrospective study, no statistically significant between-group differences were detected for most assessed clinical outcomes. Double-puncture arthrocentesis using a manually assembled unsoldered Y-shaped configuration required more needle insertion attempts, while isolated differences at 6 months favored DPA for protrusive movement and SPA Type II for self-reported masticatory function. The manually assembled configuration may represent a practical and accessible option for temporomandibular joint arthrocentesis when prefabricated cannula systems are unavailable. These findings should not be interpreted as demonstrating equivalence or superiority of either technique. ClinicalTrials.gov, NCT07327099; retrospectively registered on (24.12.2025).

BMC Oral Health
Karadeniz Technical University (TR), Ankara Yıldırım Beyazıt University (TR)
Good health and well-being
Openalex Percentile: Top 10%
Temporomandibular Joint Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.