Validation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden Illnesses

Sudden medical illnesses (SMI), including myocardial infarctions and occult arrhythmias, represent a primary etiology of catastrophic motor vehicle collisions. Although consumer wearable technologies provide a non-invasive modality for continuous driver monitoring, their measurement accuracy within dynamic automotive environments requires systematic evaluation. This investigation establishes an empirical validation paradigm for assessing the pulse-rate (PR) accuracy of consumer-grade wrist and finger photoplethysmography (PPG) devices against a reference heart rate (HR) value derived from an electrocardiographic (ECG) signal. To secure an uncompromised physiological reference, an analytical signal-processing pipeline was implemented, incorporating an Adaptive Layer-Dependent Thresholding Function (ALDTF) coupled with Maximal Overlap Discrete Wavelet Transform (MODWT) decomposition to suppress high-frequency motion artifacts and baseline wander (BW) in the ECG signal without inducing morphological distortion. Nineteen real-world driving sessions, totaling over 18 h of continuous physiological telemetry, were evaluated via Lin’s Concordance Correlation Coefficient and Bland–Altman limit-of-agreement statistics. The findings demonstrate a distinct performance bifurcation governed by device form factor and internal data filtering. The evaluated smartwatch exhibited reliable tracking (MAE = 2.73 BPM) and preserved underlying autonomic variability, attaining distributional alignment with the ECG reference in 47% of trials. Conversely, ring-based form factors demonstrated substantial perfusion decoupling induced by isometric manual gripping forces, alongside aggressive proprietary smoothing filters that suppressed micro-fluctuations in heart rate variability (0% distributional alignment). These outcomes indicate that while wrist-worn form factors possess sufficient fidelity for detecting subclinical autonomic shifts, their implementation in automotive safety systems requires access to raw data to circumvent proprietary algorithmic filtering.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-10-14
DOI
https://doi.org/10.3390/app162010201
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden Illnesses

Galidiya I. Petrova, Hristo Radev
Applied Sciences
Non-Invasive Vital Sign Monitoring
article

Validation of Commercial Wearables for Driver Monitoring: Assessing Heart Rate Accuracy and Reliability for Early Detection of Sudden Illnesses

Galidiya I. Petrova, Hristo Radev
article en

Abstract

Sudden medical illnesses (SMI), including myocardial infarctions and occult arrhythmias, represent a primary etiology of catastrophic motor vehicle collisions. Although consumer wearable technologies provide a non-invasive modality for continuous driver monitoring, their measurement accuracy within dynamic automotive environments requires systematic evaluation. This investigation establishes an empirical validation paradigm for assessing the pulse-rate (PR) accuracy of consumer-grade wrist and finger photoplethysmography (PPG) devices against a reference heart rate (HR) value derived from an electrocardiographic (ECG) signal. To secure an uncompromised physiological reference, an analytical signal-processing pipeline was implemented, incorporating an Adaptive Layer-Dependent Thresholding Function (ALDTF) coupled with Maximal Overlap Discrete Wavelet Transform (MODWT) decomposition to suppress high-frequency motion artifacts and baseline wander (BW) in the ECG signal without inducing morphological distortion. Nineteen real-world driving sessions, totaling over 18 h of continuous physiological telemetry, were evaluated via Lin’s Concordance Correlation Coefficient and Bland–Altman limit-of-agreement statistics. The findings demonstrate a distinct performance bifurcation governed by device form factor and internal data filtering. The evaluated smartwatch exhibited reliable tracking (MAE = 2.73 BPM) and preserved underlying autonomic variability, attaining distributional alignment with the ECG reference in 47% of trials. Conversely, ring-based form factors demonstrated substantial perfusion decoupling induced by isometric manual gripping forces, alongside aggressive proprietary smoothing filters that suppressed micro-fluctuations in heart rate variability (0% distributional alignment). These outcomes indicate that while wrist-worn form factors possess sufficient fidelity for detecting subclinical autonomic shifts, their implementation in automotive safety systems requires access to raw data to circumvent proprietary algorithmic filtering.

Applied SciencesVol. 16(20)
Technical University of Sofia (BG)
Good health and well-being
Openalex Percentile: Top 25%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.