Concurrent Validity of a Belt-Type IMU for Postural Sway Measurement: A Pilot Comparison with a Force Plate and Vision-Based System

Postural sway analysis is a widely used biomechanical indicator to assess balance control and fall risk in the elderly and patients with neuromuscular disorders. Although force plates are considered the gold standard for measuring the center of pressure (COP), their high cost and limited portability hinder clinical and community-based use. Recently, IMU sensors have been adopted as compact and wearable alternatives, but the concurrent validity of IMU-derived postural sway remains to be clarified. This pilot study aimed to preliminarily assess concurrent relationships between a belt-type IMU system (100 Hz) and reference systems for postural sway measurement by comparing its outcomes with those of a force plate and a vision-based system. Three healthy adults participated in static standing tests under eyes-open and eyes-closed conditions. Postural sway parameters, including COP displacement and mean velocity, were simultane-ously recorded by all three systems. Pearson correlation, linear regression, and intraclass correlation coefficients (ICC [2,1]) were used to assess correlation and inter-device agreement. The IMU-derived sway parameters showed strong correlations with both the force plate (r = 0.869-0.904) and the vision system (r = 0.882-0.939). Linear regression anal-yses demonstrated coefficients of determination ranging from R 2 = 0.75 to 0.88. The ICC results indicated moderate agreement with the force plate and moderate-to-good agreement with the vision-based system, and should be interpret-ed cautiously given the pilot sample size. These preliminary findings suggest that the belt-type IMU system yields pos-tural sway metrics that are strongly correlated with laboratory-based systems, with varying levels of agreement de-pending on the reference device. Larger-scale studies are warranted to confirm agreement and clinical utility in diverse populations and tasks.

Authors

Publication Details

Journal
Journal of Mechanics in Medicine and Biology
Published
2026-10-14
DOI
https://doi.org/10.1142/s0219519426500739
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concurrent Validity of a Belt-Type IMU for Postural Sway Measurement: A Pilot Comparison with a Force Plate and Vision-Based System

Seong‐Gi Kim, Jae‐Hak Jeong, Jong-Seon Oh
Journal of Mechanics in Medicine and Biology
Balance, Gait, and Falls Prevention
article

Concurrent Validity of a Belt-Type IMU for Postural Sway Measurement: A Pilot Comparison with a Force Plate and Vision-Based System

Seong‐Gi Kim, Jae‐Hak Jeong, Jong-Seon Oh
article en

Abstract

Postural sway analysis is a widely used biomechanical indicator to assess balance control and fall risk in the elderly and patients with neuromuscular disorders. Although force plates are considered the gold standard for measuring the center of pressure (COP), their high cost and limited portability hinder clinical and community-based use. Recently, IMU sensors have been adopted as compact and wearable alternatives, but the concurrent validity of IMU-derived postural sway remains to be clarified. This pilot study aimed to preliminarily assess concurrent relationships between a belt-type IMU system (100 Hz) and reference systems for postural sway measurement by comparing its outcomes with those of a force plate and a vision-based system. Three healthy adults participated in static standing tests under eyes-open and eyes-closed conditions. Postural sway parameters, including COP displacement and mean velocity, were simultane-ously recorded by all three systems. Pearson correlation, linear regression, and intraclass correlation coefficients (ICC [2,1]) were used to assess correlation and inter-device agreement. The IMU-derived sway parameters showed strong correlations with both the force plate (r = 0.869-0.904) and the vision system (r = 0.882-0.939). Linear regression anal-yses demonstrated coefficients of determination ranging from R 2 = 0.75 to 0.88. The ICC results indicated moderate agreement with the force plate and moderate-to-good agreement with the vision-based system, and should be interpret-ed cautiously given the pilot sample size. These preliminary findings suggest that the belt-type IMU system yields pos-tural sway metrics that are strongly correlated with laboratory-based systems, with varying levels of agreement de-pending on the reference device. Larger-scale studies are warranted to confirm agreement and clinical utility in diverse populations and tasks.

Journal of Mechanics in Medicine and Biology
Good health and well-being
Openalex Percentile: Top 6%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.