Adaptive Risk-Aware OpenStreetMap Planning for Scalable Radial Distribution Networks

A street-constrained distribution-network synthesis framework is evaluated using open geographic data, physical medium-voltage (MV) outage consequences, and benchmark electrical checks. A synthetic radial case study in Queens, New York, compares minimum-hop Dijkstra, minimum-spanning-tree connection, distance-weighted Dijkstra, Steiner approximation, conventional OpenStreetMap (OSM) routing, and Adaptive Risk OSM on shared road support for nested population representations of 20–100%. Rather than treating every low-voltage (LV) service segment as an independent contingency, it recomputes primary resilience indicators for aggregated physical MV assets. At full representation and 20 m road mesh, the selected Adaptive Risk OSM solution (α=4) has an MV length of 3.2717 km, CVaR95 of 50.42%, critical-asset share of 13.04%, interruption exposure of 0.3014 user-km/user, and targeted-removal robustness AUC of 0.2386. The six-method comparison shows that minimum-hop Dijkstra achieves the lowest CVaR95, critical-asset share, and interruption exposure; conventional OSM routing achieves the shortest MV route; and distance-weighted Dijkstra achieves the highest targeted-removal AUC. The proposed method therefore represents a risk-aware compromise rather than a universally dominant routing strategy. Benchmark three-phase balanced calculations reveal route-dependent voltage, conductor utilization, and loss differences; transformer utilization, by contrast, is governed by the common customer allocation and reaches 108.55% at threefold full-population demand, the only violating loading condition among the 150 convergent electrical cases. The findings are confined to the defined synthetic radial case and benchmark medium-voltage checks; low-voltage electrical performance is outside the validation scope.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-10-14
DOI
https://doi.org/10.3390/en19204872
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive Risk-Aware OpenStreetMap Planning for Scalable Radial Distribution Networks

Silvio Simani, Esteban Inga, Pablo Robles
Energies
Optimal Power Flow Distribution
article

Adaptive Risk-Aware OpenStreetMap Planning for Scalable Radial Distribution Networks

Silvio Simani, Esteban Inga, Pablo Robles
article en

Abstract

A street-constrained distribution-network synthesis framework is evaluated using open geographic data, physical medium-voltage (MV) outage consequences, and benchmark electrical checks. A synthetic radial case study in Queens, New York, compares minimum-hop Dijkstra, minimum-spanning-tree connection, distance-weighted Dijkstra, Steiner approximation, conventional OpenStreetMap (OSM) routing, and Adaptive Risk OSM on shared road support for nested population representations of 20–100%. Rather than treating every low-voltage (LV) service segment as an independent contingency, it recomputes primary resilience indicators for aggregated physical MV assets. At full representation and 20 m road mesh, the selected Adaptive Risk OSM solution (α=4) has an MV length of 3.2717 km, CVaR95 of 50.42%, critical-asset share of 13.04%, interruption exposure of 0.3014 user-km/user, and targeted-removal robustness AUC of 0.2386. The six-method comparison shows that minimum-hop Dijkstra achieves the lowest CVaR95, critical-asset share, and interruption exposure; conventional OSM routing achieves the shortest MV route; and distance-weighted Dijkstra achieves the highest targeted-removal AUC. The proposed method therefore represents a risk-aware compromise rather than a universally dominant routing strategy. Benchmark three-phase balanced calculations reveal route-dependent voltage, conductor utilization, and loss differences; transformer utilization, by contrast, is governed by the common customer allocation and reaches 108.55% at threefold full-population demand, the only violating loading condition among the 150 convergent electrical cases. The findings are confined to the defined synthetic radial case and benchmark medium-voltage checks; low-voltage electrical performance is outside the validation scope.

EnergiesVol. 19(20)
University of Ferrara (IT), Politecnica Salesiana University (EC)
Universidad Politécnica Salesiana del Ecuador
Industry, innovation and infrastructure, Sustainable cities and communities
Openalex Percentile: Top 24%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.