Paintable In Situ Gelling Bioelectronic Interfaces for Epidermal Electrophysiological Monitoring

Noninvasive epidermal electrophysiological monitoring is frequently constrained by unstable electrode-skin contact interfaces over soft, textured, and dynamically deforming skin. The predefined geometries of conventional electrodes limit their capacity to conform to local microtopography. Here, we introduce an in situ gelation strategy performed directly on the epidermis to construct a conformal ionic bioelectronic interface. A fluidic precursor comprising gelatin and tannic acid is initially stabilized against premature gelation via competitive solvent-solute interactions. Upon application, solvent evaporation and gelatin reassembly induce rapid network formation. This process directly yields a highly conformal and gently detachable interface with remarkably low contact impedance. The resulting hydrated dynamic network provides mechanical compliance, robust interfacial adhesion, stretch-tolerant ionic conduction, and cooling-induced interfacial weakening that enables gentle removal. The on-skin-gelled interface reduces skin-electrode contact impedance to 30 kΩ at 10 Hz, compared with 191 kΩ for commercial conductive pastes, and increases the signal-to-noise ratio from 24.9 to 27.8 dB. In proof-of-concept demonstrations, the interface supports within-subject electromyography-based gesture recognition with a classification accuracy of 93.4% and electroencephalography recordings of eye-state-dependent α-rhythm modulation as well as short-term sleep-related waveforms. These findings underscore the potential of on-skin in situ gelation as a versatile approach to fabricating paintable ionic bioelectronic interfaces for advanced electrophysiological monitoring.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-10-15
DOI
https://doi.org/10.1021/acsami.6c18381
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Paintable In Situ Gelling Bioelectronic Interfaces for Epidermal Electrophysiological Monitoring

Yong Ao, Boling Lan, Weili Deng, Xuelan Li et al.
ACS Applied Materials & Interfaces
Advanced Sensor and Energy Harvesting Materials
article

Paintable In Situ Gelling Bioelectronic Interfaces for Epidermal Electrophysiological Monitoring

Yong Ao, Boling Lan, Weili Deng, Xuelan Li, Guo Tian, Tao Yang, Yue Sun, Shenglong Wang, Yunshu Yang, Peiwen Li, Jinlong Sun, Hongguang Li, Guicen Liu, Zhiyuan Gao, Wei Zhao, Tianpei Xu, Long Jin, Longchao Huang
article en

Abstract

Noninvasive epidermal electrophysiological monitoring is frequently constrained by unstable electrode-skin contact interfaces over soft, textured, and dynamically deforming skin. The predefined geometries of conventional electrodes limit their capacity to conform to local microtopography. Here, we introduce an in situ gelation strategy performed directly on the epidermis to construct a conformal ionic bioelectronic interface. A fluidic precursor comprising gelatin and tannic acid is initially stabilized against premature gelation via competitive solvent-solute interactions. Upon application, solvent evaporation and gelatin reassembly induce rapid network formation. This process directly yields a highly conformal and gently detachable interface with remarkably low contact impedance. The resulting hydrated dynamic network provides mechanical compliance, robust interfacial adhesion, stretch-tolerant ionic conduction, and cooling-induced interfacial weakening that enables gentle removal. The on-skin-gelled interface reduces skin-electrode contact impedance to 30 kΩ at 10 Hz, compared with 191 kΩ for commercial conductive pastes, and increases the signal-to-noise ratio from 24.9 to 27.8 dB. In proof-of-concept demonstrations, the interface supports within-subject electromyography-based gesture recognition with a classification accuracy of 93.4% and electroencephalography recordings of eye-state-dependent α-rhythm modulation as well as short-term sleep-related waveforms. These findings underscore the potential of on-skin in situ gelation as a versatile approach to fabricating paintable ionic bioelectronic interfaces for advanced electrophysiological monitoring.

ACS Applied Materials & Interfaces
Glasgow School of Art (GB), Southwest Jiaotong University (CN)
Natural Science Foundation of Sichuan Province, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 25%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.