Development and Application of a High-Resolution Cryogenic STXM System at the Shanghai Synchrotron Radiation Facility

Abstract Scanning transmission X-ray microscopy (STXM) is an advanced technique for label-free chemical imaging with nanometer-scale spatial resolution which is well suited to studies of complex and heterogeneous materials. For biological and other radiation-sensitive specimens, however, the X-ray dose required for high-quality imaging often exceeds the damage threshold of the sample at room temperature. The resulting mass loss, chemical modification, and structural collapse corrupt the very signals under investigation. Cryogenic sample conditions can mitigate these effects by suppressing radiation-induced diffusion and secondary reactions. Yet their practical implementation is challenging. An instrument must simultaneously maintain stable low-temperature operation, isolate vibrations, and transfer samples without contamination under high vacuum. Satisfying all of these demands at once is difficult. Herein, we report the development and commissioning of a dedicated cryogenic STXM system installed on the beamline BL08U1A of the Shanghai Synchrotron Radiation Facility (SSRF). The instrument combines a mechanically decoupled cryostat architecture with a closed-loop ultra-high vacuum cryo-transfer system. It achieves a spatial resolution better than 30 nm and a long-term thermal drift below 0.05 nm/min. Validation on poly(methyl methacrylate) (PMMA) films shows that imaging at 120 K extends the critical radiation dose by a factor of ∼39 times compared with room temperature. Mass loss and secondary radical reactions are effectively suppressed. In situ imaging of frozen-hydrated mouse embryonic fibroblasts further resolves subcellular features such as filopodia, free from dehydration artifacts. Together, these results establish a robust platform for nondestructive, high-resolution chemical imaging of radiation-sensitive materials under near-physiological conditions, providing a foundation for correlative and multimodal studies of hydrated biological systems.

Authors

Institutions

Publication Details

Journal
Photon Science
Published
2026-10-14
DOI
https://doi.org/10.1021/photonsci.6c00071
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Application of a High-Resolution Cryogenic STXM System at the Shanghai Synchrotron Radiation Facility

Xiangjun Zhen, Renzhong Tai, Limin Zhou, Lijuan Zhang et al.
Photon Science
Advanced X-ray Imaging Techniques
article

Development and Application of a High-Resolution Cryogenic STXM System at the Shanghai Synchrotron Radiation Facility

Xiangjun Zhen, Renzhong Tai, Limin Zhou, Lijuan Zhang, Mingzheng Fang, Shixiong Zhang, Xiangzhi Zhang, Yong Wang, Zijian Xu, Zhe Niu, Xingya Wang
article en

Abstract

Abstract Scanning transmission X-ray microscopy (STXM) is an advanced technique for label-free chemical imaging with nanometer-scale spatial resolution which is well suited to studies of complex and heterogeneous materials. For biological and other radiation-sensitive specimens, however, the X-ray dose required for high-quality imaging often exceeds the damage threshold of the sample at room temperature. The resulting mass loss, chemical modification, and structural collapse corrupt the very signals under investigation. Cryogenic sample conditions can mitigate these effects by suppressing radiation-induced diffusion and secondary reactions. Yet their practical implementation is challenging. An instrument must simultaneously maintain stable low-temperature operation, isolate vibrations, and transfer samples without contamination under high vacuum. Satisfying all of these demands at once is difficult. Herein, we report the development and commissioning of a dedicated cryogenic STXM system installed on the beamline BL08U1A of the Shanghai Synchrotron Radiation Facility (SSRF). The instrument combines a mechanically decoupled cryostat architecture with a closed-loop ultra-high vacuum cryo-transfer system. It achieves a spatial resolution better than 30 nm and a long-term thermal drift below 0.05 nm/min. Validation on poly(methyl methacrylate) (PMMA) films shows that imaging at 120 K extends the critical radiation dose by a factor of ∼39 times compared with room temperature. Mass loss and secondary radical reactions are effectively suppressed. In situ imaging of frozen-hydrated mouse embryonic fibroblasts further resolves subcellular features such as filopodia, free from dehydration artifacts. Together, these results establish a robust platform for nondestructive, high-resolution chemical imaging of radiation-sensitive materials under near-physiological conditions, providing a foundation for correlative and multimodal studies of hydrated biological systems.

Photon Science
Shanghai University (CN), Chinese Academy of Sciences (CN), ShanghaiTech University (CN), University of Chinese Academy of Sciences (CN)
Salt Science Research Foundation, National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, National Key Research and Development Program of China
Openalex Percentile: Top 14%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.