Freezing performance of selective artificial ground freezing based on three-pipe structure and its influencing analysis
Selective artificial ground freezing (S-AGF) enables directional cooling and mitigates unnecessary thermal loss through air-insulated casings, thereby exhibiting superior energy-saving and stratum-protection performance relative to conventional artificial ground freezing (C-AGF). Existing S-AGF investigations have primarily concentrated on single-pipe configurations, whereas the parametric mechanisms and matching principles governing multi-pipe layouts, which are extensively deployed in engineering practice, remain insufficiently elucidated, and quantitative criteria for refined design are still lacking. Therefore, the COMSOL-based thermo-hydraulic coupled numerical simulations were conducted to investigate the freezing performance and its influencing for three-pipe S-AGF. Comparative analyses were conducted between S-AGF and C-AGF regarding frozen-wall evolution, temperature-field distribution, and energy consumption; furthermore. And the quantitative influences of pipe spacing, coolant temperature, flow velocity, and air-insulation-layer thickness on directional freezing performance were elucidated. The results demonstrate that S-AGF effectively suppresses heat diffusion within non-target strata, yielding a 50.0% reduction in peak energy consumption and a 22.6% reduction in cycle-averaged energy consumption. Pipe spacing has the dominant influence on freezing behavior, when it increases from 222 mm to 372 mm, frozen-wall closure time increases by 158%, and 322 mm is identified as the optimal spacing that balances formation efficiency and temperature uniformity. Reducing the coolant temperature from −20 °C to −35 °C shortens closure time and qualified formation time by 28.72% and 30.33%, respectively. Coolant velocity demonstrates limited regulatory capacity, with 2.0 m/s identified as the effective threshold beyond which additional velocity increments yield negligible efficiency improvements. The air gap exhibits an optimal thickness of 3.8 mm; exceeding this thickness triggers internal natural convection and consequently deteriorates insulation performance. This study could provide the quantitative design references for layout optimization, coolant-system selection, and insulated-casing fabrication in practical directional-freezing engineering applications.
Authors
- Qingyang Ren (ORCID: https://orcid.org/0000-0002-3105-754X)
- Jun Ding
- Chenyu Wang
- Hongfei Xie
- Xihao Gong
- Wenlei Wei
- Songqiang Xiao
- Liang Cheng
- Guilin Hou
- Wenfeng Zhang
Institutions
- Ningxia University (CN)
- Merchants Chongqing Communications Research and Design Institute (CN)
- Ningxia Water Conservancy (CN)
- Chongqing Construction Engineering Investment Holding (China) (CN)
- State Key Laboratory Breeding Base of Mountain Bridge and Tunnel Engineering (CN)
- Chongqing Jiaotong University (CN)
Publication Details
- Journal
- Case Studies in Thermal Engineering
- Published
- 2026-10-14
- DOI
- https://doi.org/10.1016/j.csite.2026.108592
- Primary Topic
- Geothermal Energy Systems and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- Chongqing Science and Technology Commission
- Natural Science Foundation Project of Chongqing, Chongqing Science and Technology Commission