Tuning the mechanical integrity and corrosion performance of open-cell copper foams: identification of an optimization threshold

Abstract In this work, Porous copper foam samples were fabricated by a space-holder technique with water-atomized copper powder and sodium chloride (NaCl) particles in weight fractions ranging from 10 to 35 wt%. The powders were mechanically mixed at a 10:1 ball-to-powder ratio and 150 rpm for 2 h. The effects of space-holder content on the physical, mechanical, tribological, and electrochemical performance were systematically investigated. Increasing the NaCl fraction precisely controlled the total porosity, from 39.15% to 57.76%, and reduced the bulk density from 5.452 to 3.785 g/cm³. XRD and SEM analyses confirmed a single-phase FCC copper matrix and a structural transition from isolated pores to a highly interconnected open-cell network. Consequently, Vickers hardness, compressive yield strength, energy absorption capacity decreased from 52.12 to 29.23 HV, 18.25 to 1.65 MPa, and 35.73 to 10.46 MJ/m³, respectively, following a modified Gibson–Ashby model (R 2 = 0.95). Concurrently, the coefficient of friction and specific wear rate increased (reaching a maximum of 0.73 mm³/N·m under 15 N for 35 wt% NaCl) due to strut thinning and localized delamination. Electrochemical evaluation in 3.5 wt% NaCl solution revealed an optimization threshold for sample fabricated with 25 wt% NaCl, which exhibited the lowest corrosion rate of 0.918 mm/y, and the highest polarization resistance (Rp) of 267.28 Ω, due to a stable Cu 2 O passive film. Exceeding this threshold at 30 and 35 wt% NaCl led to structural instability and stagnant electrolyte zones, accelerating corrosion kinetics. Overall, lower-porosity porous copper foam architectures offer superior structural energy absorption, whereas the 25 wt% NaCl configuration achieves an optimal balance between mechanical integrity and corrosion resistance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-10-14
DOI
https://doi.org/10.1038/s41598-026-72455-5
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tuning the mechanical integrity and corrosion performance of open-cell copper foams: identification of an optimization threshold

Moataz H. Ata, Omayma A. El-Kady, Mohamed Ali Hassan, Amr Ali et al.
Scientific Reports
Cellular and Composite Structures
article

Tuning the mechanical integrity and corrosion performance of open-cell copper foams: identification of an optimization threshold

Moataz H. Ata, Omayma A. El-Kady, Mohamed Ali Hassan, Amr Ali, Ibrahim Najih
article en

Abstract

Abstract In this work, Porous copper foam samples were fabricated by a space-holder technique with water-atomized copper powder and sodium chloride (NaCl) particles in weight fractions ranging from 10 to 35 wt%. The powders were mechanically mixed at a 10:1 ball-to-powder ratio and 150 rpm for 2 h. The effects of space-holder content on the physical, mechanical, tribological, and electrochemical performance were systematically investigated. Increasing the NaCl fraction precisely controlled the total porosity, from 39.15% to 57.76%, and reduced the bulk density from 5.452 to 3.785 g/cm³. XRD and SEM analyses confirmed a single-phase FCC copper matrix and a structural transition from isolated pores to a highly interconnected open-cell network. Consequently, Vickers hardness, compressive yield strength, energy absorption capacity decreased from 52.12 to 29.23 HV, 18.25 to 1.65 MPa, and 35.73 to 10.46 MJ/m³, respectively, following a modified Gibson–Ashby model (R 2 = 0.95). Concurrently, the coefficient of friction and specific wear rate increased (reaching a maximum of 0.73 mm³/N·m under 15 N for 35 wt% NaCl) due to strut thinning and localized delamination. Electrochemical evaluation in 3.5 wt% NaCl solution revealed an optimization threshold for sample fabricated with 25 wt% NaCl, which exhibited the lowest corrosion rate of 0.918 mm/y, and the highest polarization resistance (Rp) of 267.28 Ω, due to a stable Cu 2 O passive film. Exceeding this threshold at 30 and 35 wt% NaCl led to structural instability and stagnant electrolyte zones, accelerating corrosion kinetics. Overall, lower-porosity porous copper foam architectures offer superior structural energy absorption, whereas the 25 wt% NaCl configuration achieves an optimal balance between mechanical integrity and corrosion resistance.

Scientific ReportsVol. 16(1)
Central Metallurgical Research and Development Institute (EG), Sohag University (EG)
Industry, innovation and infrastructure
Openalex Percentile: Top 23%
Cellular and Composite Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.