Optimizing continuous-flow electrocoagulation–flotation for municipal wastewater through low-current recirculation and pulsed-current operation

Electrocoagulation–flotation (ECF) is a promising pretreatment technology for municipal wastewater (MWW), but high energy demand, operating costs, electrode passivation, and variability in reactor design constrain its wider application. This study evaluated two operational strategies for real MWW using the same reactor: semi-continuous sequential-pass effluent recirculation at 12 A/m 2 and continuous-flow direct pulsed-current (DPC) operation at 80 A/m 2 (10 min on/5 min off). Two- and three-pass recirculation were compared with single-pass direct-current (DC) operation at 40 and 80 A/m 2 , while DPC was compared with DC at 80 A/m 2 . Two-pass recirculation at 12 A/m 2 provided the most favorable balance between treatment performance and resource consumption, achieving 78% total chemical oxygen demand removal and 85% total phosphorus removal with near-unity Faradaic efficiency. Relative to DC at 40 A/m 2 , operating cost, energy consumption, and iron (Fe) consumption decreased by 39%, 47%, and 34%, respectively; corresponding reductions relative to DC at 80 A/m 2 were 74%, 86%, and 69%. Energy demand, Fe consumption, and operating cost for two-pass recirculation at 12 A/m 2 were 0.144 kWh/m 3 , 0.062 kg/m 3 , and 0.234 €/m 3 , respectively. At 80 A/m 2 , DPC reduced energy consumption, Fe consumption, operating cost, and dry-sludge production by 74%, 32%, 53%, and 76.7%, respectively. Excitation–emission matrix fluorescence spectroscopy, parallel factor analysis, and fluorescence indices indicated selective removal and changes in residual fluorescent dissolved organic matter (DOM) composition. These strategies enhanced ECF resource efficiency at bench scale; however, further pilot-scale validation involving additional independent replicates and comprehensive characterization of electrode passivation and sludge is required.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2026-10-13
DOI
https://doi.org/10.1016/j.jwpe.2026.111060
Primary Topic
Coagulation and Flocculation Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing continuous-flow electrocoagulation–flotation for municipal wastewater through low-current recirculation and pulsed-current operation

Stijn W.H. Van Hulle, Dries Parmentier, Nazia Hassan
Journal of Water Process Engineering
Coagulation and Flocculation Studies
article

Optimizing continuous-flow electrocoagulation–flotation for municipal wastewater through low-current recirculation and pulsed-current operation

Stijn W.H. Van Hulle, Dries Parmentier, Nazia Hassan
article en

Abstract

Electrocoagulation–flotation (ECF) is a promising pretreatment technology for municipal wastewater (MWW), but high energy demand, operating costs, electrode passivation, and variability in reactor design constrain its wider application. This study evaluated two operational strategies for real MWW using the same reactor: semi-continuous sequential-pass effluent recirculation at 12 A/m 2 and continuous-flow direct pulsed-current (DPC) operation at 80 A/m 2 (10 min on/5 min off). Two- and three-pass recirculation were compared with single-pass direct-current (DC) operation at 40 and 80 A/m 2 , while DPC was compared with DC at 80 A/m 2 . Two-pass recirculation at 12 A/m 2 provided the most favorable balance between treatment performance and resource consumption, achieving 78% total chemical oxygen demand removal and 85% total phosphorus removal with near-unity Faradaic efficiency. Relative to DC at 40 A/m 2 , operating cost, energy consumption, and iron (Fe) consumption decreased by 39%, 47%, and 34%, respectively; corresponding reductions relative to DC at 80 A/m 2 were 74%, 86%, and 69%. Energy demand, Fe consumption, and operating cost for two-pass recirculation at 12 A/m 2 were 0.144 kWh/m 3 , 0.062 kg/m 3 , and 0.234 €/m 3 , respectively. At 80 A/m 2 , DPC reduced energy consumption, Fe consumption, operating cost, and dry-sludge production by 74%, 32%, 53%, and 76.7%, respectively. Excitation–emission matrix fluorescence spectroscopy, parallel factor analysis, and fluorescence indices indicated selective removal and changes in residual fluorescent dissolved organic matter (DOM) composition. These strategies enhanced ECF resource efficiency at bench scale; however, further pilot-scale validation involving additional independent replicates and comprehensive characterization of electrode passivation and sludge is required.

Journal of Water Process EngineeringVol. 93
Khulna University (BD), University College West Flanders (BE)
Universiteit Gent
Openalex Percentile: Top 24%
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.